Ceiling Mount Line Voltage Occupancy Motion Sensor (RZ037-10A)

RZ037-10A

$17.00

RZ037-10A is a line voltage passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting and fan control in residential and commercial spaces.

The RZ037-10A connects directly to line voltage and mounts to the ceiling (neutral required). It offers 360° coverage with an 8–12 m detection diameter, a robust 10A load rating for multiple fixtures, push-button setup for time delay, Lux, and sensitivity, and a 1-minute warm-up on power-up for stable operation.

Main Features:

  • Auto-ON/Auto-OFF occupancy mode (Lux override available)
  • 360-degree coverage; 8–12 m detection diameter
  • 100V ~ 265V AC line voltage, 10A rating
  • Push-button adjustment: time delay, Lux, sensitivity
  • Neutral wire required; 3-wire (L, N, Load) wiring
Read more

Product highlights

  • Line voltage 100–265V AC, 10A rating (neutral required)
  • 360° ceiling-mount PIR with 8–12 m detection diameter
  • Push-button setup: Time, Lux, Sensitivity

Quick delivery: 99% in stock

Full motion-activated product line

Inquire for bulk ODM/OEM orders

Ceiling Mount Occupancy Sensor

The RZ037-10A is a ceiling-mounted 360-degree PIR motion sensor switch for dependable lighting control. Using advanced passive infrared (PIR) and microcontroller technology, it delivers stable detection and easy configuration to help reduce energy use.

With a 10A rating, it supports heavier residential and commercial lighting loads and multiple fixtures.

Easy Adjustments

Tool-free push-button setup under the top cover. Configure:

  • Time delay: 15s to 30min
  • Light sensor level: OFF, 15, 25 (default), 35 Lux
  • Sensitivity: High or Low

Note: After first power-up or power restoration, a 1-minute warm-up occurs during which the load is not controlled.

Features, Benefits, Specs

The RZ037-10A ceiling occupancy sensor provides wide 360° coverage with adjustable time delay, sensitivity, and ambient light threshold. It connects directly to line voltage and is suitable for residential and commercial applications.

Features & Benefits

  • PIR with microcontroller for stable, accurate detection
  • Adjustable time delay, Lux level, and sensitivity
  • 360° ceiling coverage with 8–12 m detection diameter
  • Neutral wire required
  • 100–265 VAC wide voltage input
Features

Sensor Mode

Occupancy mode; occupancy without light sensor (Lux OFF)

Time-Delay

15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min

Light Sensor

Off, 15 Lux, 25 Lux (default), 35 Lux

Sensor Sensitivity

Low Sensitivity, High Sensitivity

Power-Up

1-minute warm-up (no load control during warm-up)

Working Conditions

Power Source

100 VAC ~ 265 VAC

Power Frequency

50 / 60 Hz

Installation Height

2.5 m ~ 3.5 m

Working Humidity

< 93% RH

Working Temperature

-10 ~ +40℃

Detection Capability

Detection Diameter

8 m ~ 12 m (<27℃)

Detection Range

360°

Detection Speed

0.6 ~ 1.5 m/s

Load Compatibility (RZ037-10A)

Fluorescent / Ballast / LED

500 W / 110 VAC; 1000 W / 220 VAC

Incandescent / Halogen

1000 W / 110 VAC; 2200 W / 220 VAC

Versatile Applications

The RZ037 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom

Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage

Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room

Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kitchen

Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway

Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom

Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Private Office

Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Conference Room

Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.

Videos

RZ037 User Guide

Fire Resistance Testing – RZ036

Load Testing

Resources

rz021 occupancy vacanccy sensor switch residential appliction

Expand Your Motion Sensors

View all our energy-saving products on motion sensors

Reviews

There are no reviews yet.

Be the first to review “Ceiling Mount Line Voltage Occupancy Motion Sensor (RZ037-10A)”

You may also like…

English