Kit: Line Voltage Motion Sensor Switch (UK) + Wireless Motion Sensor

RZ023A+RZ023W

$32.00

The RZ023A motion detectors are equipped with an integrated wireless module, incorporate wireless technology and motion sensing capabilities for wireless communication and motion sensing capabilities.

When paired with the RZ023W wireless sensor, these two devices work in tandem to provide an extended range for motion detection, ensuring reliable lighting control. Particularly useful in narrow corridors, stairs and some large spaces.
Read more

Product highlights

  • RZ023A: Line voltage, connected to the light
  • RZ023WG: Wireless, battery powered
  • Manually turn ON/OFF the light using RZ023WG
  • Occupancy, vacancy, manual mode

Quick delivery: 99% in stock

Full motion-activated product line

Inquire for bulk ODM/OEM orders

rz023 uk occupancy vacancy sensor switch front

RZ023A: Occupancy Sensor Switch

The RZ023A motion detectors are equipped with an integrated wireless module, incorporate wireless technology and motion sensing capabilities for wireless communication and motion sensing capabilities.
When paired with the RZ023W wireless sensor, these two devices work in tandem to provide an extended range for motion detection, ensuring reliable lighting control. Particularly useful in narrow corridors, stairs and some large spaces.

RZ023W: Wireless Occupancy Sensor

The RZ023W Wireless occupancy sensor powered by 2 AAA batteries and is equipped with a wireless module. Its primary function is to detect motion and communicate with the main control sensor (RZ023A).
When motion is detected, the sensor sends a signal to the control sensor (RZ023A) to switch on or maintain the light. If neither sensor detects any movement within the user-set time period, the controller sensor (RZ023A) will determine that the space is unoccupied and switch off the light.
The RZ023W Wireless occupancy sensor can be installed in areas where wiring installation would be difficult or impossible, resulting in a significant reduction in labor and installation costs. Moreover, its wireless nature allows for future flexibility as it can be easily moved to accommodate changes in room usage or configuration.

RZ023A Wiring Diagram

5A Load: Ideal for daily home and commercial use cases for controlling lights or fans

Neutral Required: Hot Wire, Load Wire, Neutral Wire

Pairing

Transmitter(RZ023W): the device powered by battery

Receiver(RZ023A): the device connected to mains power

Add New Pairings

  • To prevent battery interference, firstly remove the battery from the transmitter or turn it back to people, there should be no other transmitters working nearby.
  • Press and hold the big button of the receiver, the red indicator will flash 1-6 times, and then release the big button after the indicator light stays on, new parings can be added at least 10 sets.
  • Install the battery on the transmitter and wait for 2-3 seconds, short press the big button of the transmitter, the learning will be successful after the indicator light flashes and goes out.

Delete Existing Pairings

  • To prevent battery interference, firstly remove the battery from the transmitter or turn it back to people, there should be no other transmitters working nearby.
  • Press and hold the small button of the receiver, the red indicator flash 1-3 times, and then release the small button after the indicator light stays on, it will erase the existing pairings.
  • Install the battery on the transmitter and wait for 2-3 seconds, short press the big button of the transmitter, the learning will be successful after the indicator light flashes and goes out

Exclusive ON/OFF Mode

One significant drawback after upgrading to motion-activated light switches is that you partially lose the ability to manually control your lights. It’s not possible to keep the lights ON like you’re used to with the good old wall switch.

The Best Of Both Worlds?

Rayzeek introduces the exclusive ON/OFF mode, allowing users to permanently keep the load ON or OFF the same as a standard light switch. It’s so convenient that users can seamlessly switch between detection mode and manual mode with only one tap.

Say goodbye to all these real-life headaches.

Pets Activate the Light at Night

Dogs and cats are active at night and might frequently trigger your motion light to turn on. That’s their nature. While most motion sensor switches do not have pet-immune features, false positives at night can be a real headache.

Select vacancy or OFF mode, especially in laundry rooms or the kitchen where your pets usually play around.

Take a Relaxing Long Bath

On average, people spend at least 8 minutes in the shower. When taking a relaxing bath at night, the light might unexpectedly turn off if the sensor can’t detect your presence in the bathing area. It can be an unpleasant experience that spoils the mood

Enter ON mode to keep the light always ON during the shower. Enjoy your hot and relaxing bath for as long as your like.

Lighting in Your Kids’ Bedroom

A vacancy sensor switch is used in bedrooms to reduce the electricity waste from the lighting left on by forgetful kids. Occupancy sensors aren’t suitable because they might activate the light at night, waking up kids, but it’s still handier in the daytime.

Now you can use occupancy sensor mode in your kid’s bedroom for the whole day. When it’s bedtime, touch the OFF button to keep the light off for the whole night.

Light False on in Empty Spaces

A fixed heat source(HVAC or hot wind) or even mirror reflection may send false positive IR signals that keep the light on when the space is unoccupied. Most of the time, it’s impossible to relocate the sensor’s position or the heat source as they’re fixed.

When the PIR sensor constantly detects signals and is falsely triggered, select OFF Mode to bypass motion detection

False off With People in the Room

Lights might falsely turn off if the sensor fails to detect the presence of people, e.g., the room is large, has obstacles blocking the IR signal, or fine motion activities such as reading or typing. It’s frustrating to repeatedly re-activate lights by moving your body.

When we need to permanently keep the light ON, enter ON mode by tapping the small button and exit without losing previous settings.

Features, Benefits, Specs

The ultimate energy-saving & lighting automation solution – switch from Auto ON/Auto OFF, Manal ON/Auto OFF, and Manal ON/Manual OFF operating mode for your multi-purpose room.

rz023 motion sensor switch manual instruction

Features & Benefits

  • Occupancy, Vacancy, Manual ON/OFF mode 3 in 1
  • Exclusive ON/OFF mode allows the sensor switch to work the same as a standard light switch
  • Time delay options: 15s, 1 min, 3 mins, 5 mins, 15 mins, 30 mins
  • Enable ambient light sensor to keep lights off when there is ample natural light
  • Low and high sensitivity adjustable
  • Adjust settings by tapping buttons without removing the switch plate
  • Magnetic latching relay provides better performance
  • Made of fire-resistant materials for your safety
  • RoHS, CE, FCC certified
RZ023A
Features

Sensor Mode

Vacancy mode, Occupancy mode, Manual ON/OFF mode

Time-Delay

15 s, 1 min(default), 3 mins, 5 mins, 15 mins, 30 mins

Light Sensor

Off, 15 Lux, 25 Lux (default), 35 Lux

Sensor Sensitivity

Low Sensitivity, High Sensitivity(Switch’s light sensor is sensitive to (infrared) thermal light source like sunlight, nature light, incandescent lamp; it’s not sensitive to cold light source like LED light,fluorescent light)

Working Conditions

Power Source

100 VAC ~ 265 VAC

Power Frequency

50 / 60Hz

Installation Height

1.2 m ~ 1.6 m

Working Humidity

< 93%RH

Working Temperature

-20 ~ +40℃

Wireless Communication Range

12-20 Meters,suggest distance between RZ022A and RZ023W not more than 12 meter.

Detection Capability

Detection Distance

7 m ~ 10 m (<27℃)

Detection Range

< 150°

Detection Speed

0.6 ~ 1.5m/s

Bulb Compatibility

Fluorescent / Ballast / LED

500 W / 220 VAC

Incandescent / Halogen

1100 W / 220 VAC

RZ023W
Features

Sensor Mode

Vacancy mode, Occupancy mode, Manual ON/OFF mode

Time-Delay

15 s, 1 min(default), 3 mins, 5 mins, 15 mins, 30 mins

Light Sensor

Off, 15 Lux, 25 Lux (default), 35 Lux

Sensor Sensitivity

Low Sensitivity, High Sensitivity

Working Conditions

Power Source

2pcs*AAA battery

Installation Height

1 m ~ 1.6 m

Working Humidity

< 93%RH

Working Temperature

-20 ~ +40℃

Communication range

12-20Meters,suggest distance between RZ022A and RZ023W not more than 12meter

Detection Capability

Detection Distance

6-9m max(<24℃)

Detection Range

< 150°

Detection Speed

0.6 ~ 1.5m/s

The Ideal Repalcement

The Rayzeek RZ023 motion sensor switch is ideal for replacing wall switches in the UK area and countries utilizing the British standard 86 type square wall switch boxes. The 100V- 265V wide voltage range makes RZ023 applicable to all regions using 220V to 240V AC voltages.

rz023 occupancy vacancy sensor switch dimension

RZ023-5A

  • 5A Load: Ideal for daily home and commercial use cases for controlling lights or fans
  • 3-Wire Wiring: Hot Wire, Load Wire, Neutral Wire

Need more load for more lights?

uk-box

UK Standard Switch

RZ023 motion sensor switch is designed for the UK market and fits in the standard 86 type pattress boxes. Also suitable for countries using British standard back boxes:

  • United Arab Emirates
  • United Kingdom
  • Hong Kong
  • Ireland Israel
  • Malaysia
  • Portugal
  • Saudi Arabia
  • Singapore
  • Turkey

Versatile Applications

Rayzeek RZ023 motion sensor switch is the ultimate solution for automating your home lighting. It can act as an occupancy sensor, vacancy sensor, or a standard light switch to suit the diverse needs of every space. Simply upgrade all your light switches with RZ023 without a second thought because you can always change it to a manual ON/OFF switch when needed.

Bathroom

Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage

Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room

Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kitchen

Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway

Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom

Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Private Office

Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Conference Room

Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.

Videos

RZ023 User Guide

RZ023 Programming Guide

RZ023 (Neutral Required) – Installation Video

Fire Resistance Testing – RZ023

Load Testing

Resources

uk rz023 occupancy sensor c2a

Expand Your Motion Sensors

View all our energy-saving products on motion sensors

Reviews

There are no reviews yet.

Be the first to review “Kit: Line Voltage Motion Sensor Switch (UK) + Wireless Motion Sensor”

You may also like…

en_USEnglish