RZ038-5A 360-Degree Recessed Ceiling PIR Motion Sensor Switch
RZ038-5A
$15.00
RZ038-5A is a 100-265 VAC recessed ceiling PIR motion sensor switch for automatic lighting control in residential and light commercial rooms.
The 5A model uses live, neutral, and load wiring and provides 360-degree PIR coverage, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted occupancy control.
- 100-265 VAC line-voltage input, 5A model
- 360-degree PIR detection with 8-12 m detection diameter
- Time delay: 15 s to 30 min
- Lux setting: Off, 15, 25, or 35 Lux
- Neutral wire required for AC wiring
Points forts du produit
- 5A AC model: 100-265 VAC recessed ceiling sensor switch for verified RZ038-5A load ratings.
- Ceiling PIR coverage: 360-degree detection with 8-12 m detection diameter under manual conditions.
- Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.
Ce n'est pas ce que vous recherchez ? Voir notre portefeuille :
Consulter un expert
Livraison rapide : 99% en stock
Gamme complète de produits activés par le mouvement
Demande de renseignements pour les commandes en gros ODM/OEM

Recessed 5A Ceiling Control For Everyday Lighting Loads
The RZ038-5A is a recessed ceiling-mounted PIR motion sensor switch for automatic lighting control where a discreet ceiling sensor is preferred over a wall switch.
It connects to 100-265 VAC circuits with live, neutral, and load wiring, giving installers adjustable time delay, Lux level, and sensitivity in a compact spring-clip ceiling form.

Lux Control For Rooms With Changing Daylight
The built-in light sensor can hold lighting off when ambient light is above the selected threshold, helping the sensor respond to motion only when the room needs light.
Use the Off, 15 Lux, 25 Lux, or 35 Lux setting to match bathrooms, utility rooms, hallways, or other indoor areas where daylight and occupancy change during the day.
Caractéristiques, avantages, spécifications
The RZ038-5A combines 360-degree PIR detection, 100-265 VAC wiring, and verified 5A load ratings so installers can check coverage, setup, and lighting compatibility before ordering.

Caractéristiques et avantages
- 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ038-5A load ratings shown in the specifications.
- 360-degree PIR detection: Ceiling placement gives broad room coverage with an 8-12 m detection diameter when installed within the manual conditions.
- Adjustable time delay: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match the room traffic pattern.
- Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux to control whether motion can switch lights on when ambient light is present.
- High/low sensitivity: The SENS button lets installers tune detection response for the room layout.
- Spring clip or screw mounting: Mount into an 82-90 mm ceiling cutout or secure to a ceiling/junction box using the documented methods.
- Caractéristiques
-
Model
RZ038-5A
Product type
Recessed ceiling mount PIR motion sensor switch
Sensor type
Passive infrared (PIR)
Délai
15 s, 30 s, 1 min (par défaut), 3 min, 5 min, 10 min, 30 min
Light sensor level
Arrêt, 15 Lux, 25 Lux (par défaut), 35 Lux
Sensibilité
High or Low
Power-up behavior
1-minute warm-up after power is turned on or restored
- Electrical
-
Source d'alimentation
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
Câblage
White to Neutral; Red to Load; Black to Live
Incandescent / Halogen load
500 W / 110 VAC ; 1100 W / 220 VAC
Fluorescent / Ballast / LED load
250 W / 110 VAC ; 500 W / 220 VAC
- Detection & Installation
-
Detection diameter
8-12 m when ambient temperature is below 27 C
Detection range
360-degree ceiling coverage
Motion detection speed
0.6-1.5 m/s
Installation height
2.5-3.5 m
Working temperature
-10 to +40 C
Working humidity
< 93% RH
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
FAQ
Does the RZ038-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
Can the sensor keep lights off during bright daylight?
Yes. The Lux button can set Off, 15 Lux, 25 Lux, or 35 Lux, so the light sensor threshold can be matched to the room.
Where should this ceiling sensor be installed?
The manual recommends a 2.5-3.5 m installation height and advises avoiding heat sources, forced air, ventilation systems, ceiling fans, and hanging light fixtures near the sensor.
What happens after power is restored?
The sensor has a 1-minute warm-up period after power-up or power restoration. During that time it will not automatically control the load.
Should I choose the 5A or 10A RZ038 model?
Choose by verified load requirement. The 10A model has higher source-backed load ratings, while the 5A model is for lower-load AC lighting circuits.









Avis
Il n’y a pas encore d’avis.