Product video
RZ038-5A 360-Degree Recessed Ceiling PIR Motion Sensor Switch
RZ038-5A
$15.00
RZ038-5A is a 100-265 VAC recessed ceiling PIR motion sensor switch for automatic lighting control in residential and light commercial rooms.
The 5A model uses live, neutral, and load wiring and provides 360-degree PIR coverage, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted occupancy control.
- 100-265 VAC рд▓рд╛рдЗрди-рд╡реЛрд▓реНрдЯреЗрдЬ рдЗрдирдкреБрдЯ, 5A рдореЙрдбрд▓
- 360-degree PIR detection with 8-12 m detection diameter
- Time delay: 15 s to 30 min
- Lux setting: Off, 15, 25, or 35 Lux
- Neutral wire required for AC wiring
рдЙрддреНрдкрд╛рдж рдХреА рдореБрдЦреНрдп рд╡рд┐рд╢реЗрд╖рддрд╛рдПрдВ
- 5A AC model: 100-265 VAC recessed ceiling sensor switch for verified RZ038-5A load ratings.
- Ceiling PIR coverage: 360-degree detection with 8-12 m detection diameter under manual conditions.
- Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.
рдЖрдк рдЬреЛ рдЦреЛрдЬ рд░рд╣реЗ рд╣реИрдВ рд╡рд╣ рдирд╣реАрдВ рд╣реИ? рд╣рдорд╛рд░рд╛ рдкреЛрд░реНрдЯрдлреЛрд▓рд┐рдпреЛ рджреЗрдЦреЗрдВ:
- рдореЛрд╢рди рд╕реЗрдВрд╕рд░ рд╕реНрд╡рд┐рдЪ: рдореИрдиреБрдЕрд▓ рдУрд╡рд░рд░рд╛рдЗрдб рдХреЗ рд╕рд╛рде рдпреВрдПрд╕/рдпреВрдХреЗ/рдИрдпреВ рдЗрдВрд╕реНрдЯреЙрд▓реЗрд╢рди рдХреЗ рд▓рд┐рдП рд╣рд╛рд░реНрдбрд╡рд╛рдпрд░реНрдб/рд╡рд╛рдпрд░рд▓реЗрд╕
- рдЕрдзрд┐рднреЛрдЧ/рд░рд┐рдХреНрддрддрд╛ рд╕реЗрдВрд╕рд░
- рдХрдо рд╡реЛрд▓реНрдЯреЗрдЬ рдбреАрд╕реА рдореЛрд╢рди рд╕реЗрдВрд╕рд░
рдХрд┐рд╕реА рд╡рд┐рд╢реЗрд╖рдЬреНрдЮ рд╕реЗ рд╕рд▓рд╛рд╣ рд▓реЗрдВ
рд╢реАрдШреНрд░ рдбрд┐рд▓реАрд╡рд░реА: рд╕реНрдЯреЙрдХ рдореЗрдВ 99%
рдкреВрд░реНрдг рдЧрддрд┐-рд╕рдХреНрд░рд┐рдп рдЙрддреНрдкрд╛рдж рд▓рд╛рдЗрди
рдкреВрдЫрддрд╛рдЫ рдХрд░реЗрдВ рдереЛрдХ ODM/OEM рдСрд░реНрдбрд░ рдХреЗ рд▓рд┐рдП

Recessed 5A Ceiling Control For Everyday Lighting Loads
The RZ038-5A is a recessed ceiling-mounted PIR motion sensor switch for automatic lighting control where a discreet ceiling sensor is preferred over a wall switch.
It connects to 100-265 VAC circuits with live, neutral, and load wiring, giving installers adjustable time delay, Lux level, and sensitivity in a compact spring-clip ceiling form.

Lux Control For Rooms With Changing Daylight
The built-in light sensor can hold lighting off when ambient light is above the selected threshold, helping the sensor respond to motion only when the room needs light.
Use the Off, 15 Lux, 25 Lux, or 35 Lux setting to match bathrooms, utility rooms, hallways, or other indoor areas where daylight and occupancy change during the day.
рд╡рд┐рд╢реЗрд╖рддрд╛рдПрдВ, рд▓рд╛рдн, рд╡рд┐рдирд┐рд░реНрджреЗрд╢
The RZ038-5A combines 360-degree PIR detection, 100-265 VAC wiring, and verified 5A load ratings so installers can check coverage, setup, and lighting compatibility before ordering.

рд╡рд┐рд╢реЗрд╖рддрд╛рдПрдВ рдФрд░ рд▓рд╛рдн
- 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ038-5A load ratings shown in the specifications.
- 360-degree PIR detection: Ceiling placement gives broad room coverage with an 8-12 m detection diameter when installed within the manual conditions.
- рд╕рдорд╛рдпреЛрдЬреНрдп рд╕рдордп рд╡рд┐рд▓рдВрдм: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match the room traffic pattern.
- Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux to control whether motion can switch lights on when ambient light is present.
- High/low sensitivity: The SENS button lets installers tune detection response for the room layout.
- Spring clip or screw mounting: Mount into an 82-90 mm ceiling cutout or secure to a ceiling/junction box using the documented methods.
- рд╡рд┐рд╢реЗрд╖рддрд╛рдПрдБ
-
рдореЙрдбрд▓
RZ038-5A
рдЙрддреНрдкрд╛рдж рдкреНрд░рдХрд╛рд░
Recessed ceiling mount PIR motion sensor switch
рд╕реЗрдВрд╕рд░ рдкреНрд░рдХрд╛рд░
рдкреИрд╕рд┐рд╡ рдЗрдВрдлреНрд░рд╛рд░реЗрдб (PIR)
рд╕рдордп рд╡рд┐рд▓рдВрдм
15 рд╕реЗрдХрдВрдб, 30 рд╕реЗрдХрдВрдб, 1 рдорд┐рдирдЯ (рдбрд┐рдлрд╝реЙрд▓реНрдЯ), 3 рдорд┐рдирдЯ, 5 рдорд┐рдирдЯ, 10 рдорд┐рдирдЯ, 30 рдорд┐рдирдЯ
Light sensor level
рдмрдВрдж, 15 рд▓рдХреНрд╕, 25 рд▓рдХреНрд╕ (рдбрд┐рдлрд╝реЙрд▓реНрдЯ), 35 рд▓рдХреНрд╕
рд╕рдВрд╡реЗрджрдирд╢реАрд▓рддрд╛
High or Low
Power-up behavior
1-minute warm-up after power is turned on or restored
- Electrical
-
рдмрд┐рдЬрд▓реА рдХрд╛ рд╕реНрд░реЛрдд
100 VAC ~ 265 VAC
рдмрд┐рдЬрд▓реА рдЖрд╡реГрддреНрддрд┐
50/60 Hz
рд╡рд╛рдпрд░рд┐рдВрдЧ
White to Neutral; Red to Load; Black to Live
Incandescent / Halogen load
500 W / 110 VAC; 1100 W / 220 VAC
Fluorescent / Ballast / LED load
250 W / 110 VAC; 500 W / 220 VAC
- Detection & Installation
-
рдЦрдирди рд╡реНрдпрд╛рд╕
8-12 m when ambient temperature is below 27 C
рдкрд╣рдЪрд╛рди рд░реЗрдВрдЬ
360-degree ceiling coverage
Motion detection speed
0.6-1.5 m/s
рд╕реНрдерд╛рдкрдирд╛ рдКрдВрдЪрд╛рдИ
2.5-3.5 m
рдХрд╛рдо рдХрд░рдиреЗ рдХрд╛ рддрд╛рдкрдорд╛рди
-10 to +40 C
рдХрд╛рдо рдХрд░рдиреЗ рдХреА рдЖрд░реНрджреНрд░рддрд╛
< 93% RH
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
рд╕рд╛рдорд╛рдиреНрдп рдкреНрд░рд╢реНрди
Does the RZ038-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
Can the sensor keep lights off during bright daylight?
Yes. The Lux button can set Off, 15 Lux, 25 Lux, or 35 Lux, so the light sensor threshold can be matched to the room.
Where should this ceiling sensor be installed?
The manual recommends a 2.5-3.5 m installation height and advises avoiding heat sources, forced air, ventilation systems, ceiling fans, and hanging light fixtures near the sensor.
What happens after power is restored?
The sensor has a 1-minute warm-up period after power-up or power restoration. During that time it will not automatically control the load.
Should I choose the 5A or 10A RZ038 model?
Choose by verified load requirement. The 10A model has higher source-backed load ratings, while the 5A model is for lower-load AC lighting circuits.