RZ038-5A is a 100-265 VAC recessed ceiling PIR motion sensor switch for automatic lighting control in residential and light commercial rooms.

The 5A model uses live, neutral, and load wiring and provides 360-degree PIR coverage, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted occupancy control.

  • āļ­āļīāļ™āļžāļļāļ•āđāļĢāļ‡āļ”āļąāļ™āđ„āļŸāļŠāļēāļĒāļŠāđˆāļ‡ 100-265 VAC āļĢāļļāđˆāļ™ 5A
  • 360-degree PIR detection with 8-12 m detection diameter
  • Time delay: 15 s to 30 min
  • Lux setting: Off, 15, 25, or 35 Lux
  • Neutral wire required for AC wiring
āļ­āđˆāļēāļ™āđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄ

āđ„āļŪāđ„āļĨāļ—āđŒāļŠāļīāļ™āļ„āđ‰āļē

  • 5A AC model: 100-265 VAC recessed ceiling sensor switch for verified RZ038-5A load ratings.
  • Ceiling PIR coverage: 360-degree detection with 8-12 m detection diameter under manual conditions.
  • Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.

āđ„āļĄāđˆāđƒāļŠāđˆāļŠāļīāđˆāļ‡āļ—āļĩāđˆāļ„āļļāļ“āļāļģāļĨāļąāļ‡āļĄāļ­āļ‡āļŦāļē? āļ”āļđāļœāļĨāļ‡āļēāļ™āļ‚āļ­āļ‡āđ€āļĢāļē:

āļ›āļĢāļķāļāļĐāļēāļœāļđāđ‰āđ€āļŠāļĩāđˆāļĒāļ§āļŠāļēāļ

āļˆāļąāļ”āļŠāđˆāļ‡āļ”āđˆāļ§āļ™: āļŠāļīāļ™āļ„āđ‰āļēāļ„āļ‡āļ„āļĨāļąāļ‡ 99%

āļŠāļēāļĒāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒāļ—āļĩāđˆāđ€āļ›āļīāļ”āđƒāļŠāđ‰āļ‡āļēāļ™āļ”āđ‰āļ§āļĒāļāļēāļĢāđ€āļ„āļĨāļ·āđˆāļ­āļ™āđ„āļŦāļ§āđ€āļ•āđ‡āļĄāļĢāļđāļ›āđāļšāļš

āļŠāļ­āļšāļ–āļēāļĄ āļŠāļģāļŦāļĢāļąāļšāļ„āļģāļŠāļąāđˆāļ‡ ODM/OEM āļˆāļģāļ™āļ§āļ™āļĄāļēāļ

RZ038-5A recessed ceiling PIR motion sensor switch front view

Recessed 5A Ceiling Control For Everyday Lighting Loads

The RZ038-5A is a recessed ceiling-mounted PIR motion sensor switch for automatic lighting control where a discreet ceiling sensor is preferred over a wall switch.

It connects to 100-265 VAC circuits with live, neutral, and load wiring, giving installers adjustable time delay, Lux level, and sensitivity in a compact spring-clip ceiling form.

RZ038 daylight sensor lux adjustment in bathroom lighting application

Lux Control For Rooms With Changing Daylight

The built-in light sensor can hold lighting off when ambient light is above the selected threshold, helping the sensor respond to motion only when the room needs light.

Use the Off, 15 Lux, 25 Lux, or 35 Lux setting to match bathrooms, utility rooms, hallways, or other indoor areas where daylight and occupancy change during the day.

āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī, āļ‚āđ‰āļ­āļ”āļĩ, āļŠāđ€āļ›āļ„

The RZ038-5A combines 360-degree PIR detection, 100-265 VAC wiring, and verified 5A load ratings so installers can check coverage, setup, and lighting compatibility before ordering.

RZ038 AC line voltage wiring and spring clip installation diagram

āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī & āļ‚āđ‰āļ­āļ”āļĩ

  • 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ038-5A load ratings shown in the specifications.
  • 360-degree PIR detection: Ceiling placement gives broad room coverage with an 8-12 m detection diameter when installed within the manual conditions.
  • āļ›āļĢāļąāļšāđ€āļ§āļĨāļēāļŦāļ™āđˆāļ§āļ‡āđ„āļ”āđ‰: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match the room traffic pattern.
  • Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux to control whether motion can switch lights on when ambient light is present.
  • High/low sensitivity: The SENS button lets installers tune detection response for the room layout.
  • Spring clip or screw mounting: Mount into an 82-90 mm ceiling cutout or secure to a ceiling/junction box using the documented methods.
āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī

āļĢāļļāđˆāļ™

RZ038-5A

āļ›āļĢāļ°āđ€āļ āļ—āļŠāļīāļ™āļ„āđ‰āļē

āļŠāļ§āļīāļ•āļŠāđŒāđ€āļ‹āļ™āđ€āļ‹āļ­āļĢāđŒāļ•āļĢāļ§āļˆāļˆāļąāļšāļāļēāļĢāđ€āļ„āļĨāļ·āđˆāļ­āļ™āđ„āļŦāļ§ PIR āđāļšāļšāļāļąāļ‡āđ€āļžāļ”āļēāļ™

āļ›āļĢāļ°āđ€āļ āļ—āđ€āļ‹āđ‡āļ™āđ€āļ‹āļ­āļĢāđŒ

āļ­āļīāļ™āļŸāļĢāļēāđ€āļĢāļ”āđāļšāļšāļžāļēāļŠāļ‹āļĩāļŸ (PIR)

āļ”āļĩāđ€āļĨāļĒāđŒāđ€āļ§āļĨāļē

15 āļ§āļīāļ™āļēāļ—āļĩ, 30 āļ§āļīāļ™āļēāļ—āļĩ, 1 āļ™āļēāļ—āļĩ (āļ„āđˆāļēāđ€āļĢāļīāđˆāļĄāļ•āđ‰āļ™), 3 āļ™āļēāļ—āļĩ, 5 āļ™āļēāļ—āļĩ, 10 āļ™āļēāļ—āļĩ, 30 āļ™āļēāļ—āļĩ

Light sensor level

āļ›āļīāļ”, 15 āļĨāļąāļāļ‹āđŒ, 25 āļĨāļąāļāļ‹āđŒ (āļ„āđˆāļēāđ€āļĢāļīāđˆāļĄāļ•āđ‰āļ™), 35 āļĨāļąāļāļ‹āđŒ

āļ„āļ§āļēāļĄāđ„āļ§

High or Low

Power-up behavior

1-minute warm-up after power is turned on or restored

Electrical

āđāļŦāļĨāđˆāļ‡āļˆāđˆāļēāļĒāđ„āļŸ

100 VAC ~ 265 VAC

āļ„āļ§āļēāļĄāļ–āļĩāđˆāđ„āļŸāļŸāđ‰āļē

50/60 Hz

āļŠāļēāļĒāđ„āļŸ

White to Neutral; Red to Load; Black to Live

Incandescent / Halogen load

500 W / 110 VAC; 1100 W / 220 VAC

Fluorescent / Ballast / LED load

250 W / 110 VAC; 500 W / 220 VAC

Detection & Installation

āđ€āļŠāđ‰āļ™āļœāđˆāļēāļ™āļĻāļđāļ™āļĒāđŒāļāļĨāļēāļ‡āļāļēāļĢāļ•āļĢāļ§āļˆāļˆāļąāļš

8-12 m when ambient temperature is below 27 C

āļŠāđˆāļ§āļ‡āļāļēāļĢāļ•āļĢāļ§āļˆāļˆāļąāļš

360-degree ceiling coverage

Motion detection speed

0.6-1.5 m/s

āļ„āļ§āļēāļĄāļŠāļđāļ‡āđƒāļ™āļāļēāļĢāļ•āļīāļ”āļ•āļąāđ‰āļ‡

2.5-3.5 m

āļ­āļļāļ“āļŦāļ āļđāļĄāļīāļāļēāļĢāļ—āļģāļ‡āļēāļ™

-10 to +40 C

āļ„āļ§āļēāļĄāļŠāļ·āđ‰āļ™āđƒāļ™āļāļēāļĢāļ—āļģāļ‡āļēāļ™

< 93% RH

Ceiling cutout

82-90 mm circular hole for spring clip mounting

Face diameter

106 mm

āļ„āļģāļ–āļēāļĄāļ—āļĩāđˆāļžāļšāļšāđˆāļ­āļĒ

Does the RZ038-5A need a neutral wire?

Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.

What loads can the 5A model control?

The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.

Can the sensor keep lights off during bright daylight?

Yes. The Lux button can set Off, 15 Lux, 25 Lux, or 35 Lux, so the light sensor threshold can be matched to the room.

Where should this ceiling sensor be installed?

The manual recommends a 2.5-3.5 m installation height and advises avoiding heat sources, forced air, ventilation systems, ceiling fans, and hanging light fixtures near the sensor.

What happens after power is restored?

The sensor has a 1-minute warm-up period after power-up or power restoration. During that time it will not automatically control the load.

Should I choose the 5A or 10A RZ038 model?

Choose by verified load requirement. The 10A model has higher source-backed load ratings, while the 5A model is for lower-load AC lighting circuits.

EU rz022 āđ€āļ‹āđ‡āļ™āđ€āļ‹āļ­āļĢāđŒāļ•āļĢāļ§āļˆāļˆāļąāļšāļāļēāļĢāļ„āļĢāļ­āļšāļ„āļĢāļ­āļ‡ c2a

āļ‚āļĒāļēāļĒāđ€āļ‹āđ‡āļ™āđ€āļ‹āļ­āļĢāđŒāļ•āļĢāļ§āļˆāļˆāļąāļšāļāļēāļĢāđ€āļ„āļĨāļ·āđˆāļ­āļ™āđ„āļŦāļ§āļ‚āļ­āļ‡āļ„āļļāļ“

āļ”āļđāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒāļ›āļĢāļ°āļŦāļĒāļąāļ”āļžāļĨāļąāļ‡āļ‡āļēāļ™āļ—āļąāđ‰āļ‡āļŦāļĄāļ”āļ‚āļ­āļ‡āđ€āļĢāļēāđ€āļāļĩāđˆāļĒāļ§āļāļąāļšāđ€āļ‹āđ‡āļ™āđ€āļ‹āļ­āļĢāđŒāļ•āļĢāļ§āļˆāļˆāļąāļšāļāļēāļĢāđ€āļ„āļĨāļ·āđˆāļ­āļ™āđ„āļŦāļ§

āļĢāļĩāļ§āļīāļ§

āļĒāļąāļ‡āđ„āļĄāđˆāļĄāļĩāļšāļ—āļ§āļīāļˆāļēāļĢāļ“āđŒ

āļĄāļēāđ€āļ›āđ‡āļ™āļ„āļ™āđāļĢāļāļ—āļĩāđˆāļ§āļīāļˆāļēāļĢāļ“āđŒ “RZ038-5A 360-Degree Recessed Ceiling PIR Motion Sensor Switch”

Thai