RZ047-10A 360-Degree Ceiling Microwave Motion Sensor Switch
RZ047-10A
RZ047-10A is the higher-load AC version of the ceiling-mounted microwave motion sensor switch for automatic lighting control.
It keeps the same 5.8 GHz microwave sensing platform as the 5A model while using source-backed 10A load ratings for compatible 100-265 VAC lighting circuits.
- 100-265 VAC line-voltage input, 10A model
- 5.8 GHz microwave sensing with 360-degree coverage
- 8-12 m detection diameter under manual conditions
- Time delay: 15 s to 30 min
- Lux setting: Off, 15, 25, or 35 Lux
Основные характеристики продукта
- 10A AC model: 100-265 VAC ceiling microwave sensor switch with higher source-backed load ratings than the 5A model.
- Microwave sensing: 5.8 GHz Doppler detection with 360-degree ceiling coverage.
- Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.
Не то, что вы ищете? Ознакомьтесь с нашим портфолио:
Проконсультируйтесь с экспертом
Быстрая доставка: 99% в наличии
Полная линейка продуктов с функцией активации движения
Спрашивайте для оптовых заказов ODM/OEM

Higher-Load AC Microwave Control From The Ceiling
The RZ047-10A is the higher-load AC model in the RZ047 ceiling microwave sensor family, built for automatic lighting control where a ceiling sensor is the right detection position.
It uses 100-265 VAC live, neutral, and load wiring, with manual adjustment for time delay, Lux threshold, and high/low sensitivity after installation.

Higher-Load AC Sensing For Shared Indoor Lighting
Use the RZ047-10A when the project needs the RZ047 microwave sensing platform and the higher verified AC load profile shown in the manual.
Ceiling placement can suit corridors, shared rooms, utility areas, and similar indoor spaces, provided the sensor is positioned to avoid unwanted detection through doors, windows, partitions, metal surfaces, or moving equipment.
Характеристики, преимущества, спецификации
The RZ047-10A pairs 10A AC load ratings with 5.8 GHz microwave detection so installers can compare load capacity, room coverage, and adjustment options before ordering.

Особенности и преимущества
- 10A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ047-10A load ratings shown in the specifications.
- Higher AC load profile: The 10A model is the RZ047 choice when the verified lighting load exceeds the 5A model rating.
- 5.8 GHz microwave sensing: High-frequency Doppler detection actively senses movement for ceiling-mounted automatic lighting control.
- 360-degree ceiling coverage: Ceiling placement gives broad room coverage with an 8-12 m detection diameter under manual conditions.
- Non-metal material penetration: Microwave detection can pass through many plastics, glass, and thin partitions, while metal blocks detection.
- Adjustable time delay: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match room traffic patterns.
- High/low sensitivity: The SENS button helps reduce nuisance detection through doors, glass, partitions, or adjacent spaces.
- Характеристики
-
Model
RZ047-10A
Product type
Ceiling-mounted microwave motion sensor switch
Sensor type
High-frequency microwave Doppler (HF)
Microwave frequency
5.8 GHz ISM band
Transmission power
0.4 mW
Задержка времени
15 с, 30 с, 1 мин (по умолчанию), 3 мин, 5 мин, 10 мин, 30 мин
Light sensor level
Выкл, 15 Люкс, 25 Люкс (по умолчанию), 35 Люкс
Чувствительность
High or Low
Material penetration
Detects through most plastics, glass, and thin partitions; metal blocks detection
- Electrical
-
Источник питания
100 В ~ 265 В
Power frequency
50/60 Hz
Проводка
White to Neutral; Red to Load; Black to Live
Потребляемая мощность
<=0.5 W standby; 1 W operation
Incandescent / Halogen load
1000 Вт / 110 В переменного тока; 2200 Вт / 220 В переменного тока
Fluorescent / Ballast / LED load
500 Вт / 110 В переменного тока; 1000 Вт / 220 В переменного тока
- Detection & Installation
-
Detection diameter
8-12 m
Detection range
360-degree ceiling coverage
Installation height
2.5-5 m
Working temperature
-10 to +40 C
Working humidity
< 93% RH non-condensing
Metal clearance
Keep at least 1 m from large metal or highly reflective surfaces; do not fully enclose in metal
Installation notes
Avoid windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, and vibrating fixtures that may cause nuisance detection
ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ
How is the RZ047-10A different from the 5A model?
The 10A model has higher verified AC load ratings. Both models use 100-265 VAC input, neutral-required wiring, and the same RZ047 ceiling microwave sensing platform.
Does the RZ047-10A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 10A model control?
The manual lists 1000 W / 110 VAC and 2200 W / 220 VAC for incandescent or halogen loads, and 500 W / 110 VAC and 1000 W / 220 VAC for fluorescent, ballast, or LED loads.
Can microwave sensing detect through glass or partitions?
Yes. The manual states that microwave sensing can detect through most plastics, glass, and thin partitions, while metal blocks detection. Placement and sensitivity should be adjusted accordingly.
How can nuisance triggering be reduced?
Reduce sensitivity to Low or relocate the sensor to avoid doors, windows, adjacent spaces, moving machinery, HVAC airflow, fans, vibrating fixtures, and large metal or reflective surfaces.
What time delay settings are available?
Time delay settings are 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, and 30 min. The manual default is 1 min.





Отзывы
Пока отзывов нет.