{"id":18027,"date":"2024-05-21T09:12:15","date_gmt":"2024-05-21T09:12:15","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=18027"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"storage-room-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-arrecadacoes","title":{"rendered":"Guia de design para arrecada\u00e7\u00f5es"},"content":{"rendered":"<div class=\"wp-block-cover alignfull rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18031\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"storage-rooms\">salas de armazenamento<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Descubra o potencial de poupan\u00e7a de energia das arrecada\u00e7\u00f5es com o guia de conce\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o da Rayzeek.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg\" alt=\"\" class=\"wp-image-18030\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-storage-rooms-with-occupancy-sensors\">Maximize a Efici\u00eancia Energ\u00e9tica em Arrecada\u00e7\u00f5es com Sensores de Ocupa\u00e7\u00e3o<\/h2>\n\n<p>As salas de armazenamento, frequentemente negligenciadas, s\u00e3o partes integrantes dos edif\u00edcios comerciais. Estes espa\u00e7os est\u00e3o normalmente repletos de prateleiras, caixas e v\u00e1rios itens, e s\u00e3o utilizados para armazenar consum\u00edveis, equipamento ou documentos arquivados. A ilumina\u00e7\u00e3o nestas \u00e1reas \u00e9 crucial para a visibilidade e a seguran\u00e7a, mas tamb\u00e9m pode ser uma fonte significativa de desperd\u00edcio de energia. Os sistemas de ilumina\u00e7\u00e3o tradicionais em salas de armazenamento s\u00e3o frequentemente deixados ligados desnecessariamente, levando a um elevado consumo de energia e custos.<\/p>\n\n<p>Al\u00e9m disso, as arrecada\u00e7\u00f5es est\u00e3o normalmente equipadas com luzes fluorescentes ou LED que, embora eficientes em termos energ\u00e9ticos, podem ainda consumir uma quantidade consider\u00e1vel de energia quando deixadas acesas durante longos per\u00edodos. A natureza espor\u00e1dica e imprevis\u00edvel da utiliza\u00e7\u00e3o das arrecada\u00e7\u00f5es agrava ainda mais este problema, pois as luzes s\u00e3o frequentemente deixadas acesas mesmo quando o espa\u00e7o est\u00e1 desocupado, levando a desperd\u00edcio de energia desnecess\u00e1rio.<\/p>\n\n<p>Este desperd\u00edcio de energia pode ser mitigado atrav\u00e9s da utiliza\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o. Estes dispositivos controlam automaticamente a ilumina\u00e7\u00e3o com base na presen\u00e7a ou aus\u00eancia de pessoas, garantindo que as luzes est\u00e3o ligadas apenas quando necess\u00e1rio. Ao instalar sensores de ocupa\u00e7\u00e3o em salas de armazenamento, as empresas podem reduzir significativamente o seu consumo de energia, diminuir as suas faturas de servi\u00e7os p\u00fablicos e contribuir para um ambiente mais sustent\u00e1vel.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Conhe\u00e7a os C\u00f3digos de Energia<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>O International Energy Conservation Code (IECC) \u00e9 um c\u00f3digo-modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos m\u00ednimos de conce\u00e7\u00e3o e constru\u00e7\u00e3o para a efici\u00eancia energ\u00e9tica nos edif\u00edcios. O IECC \u00e9 atualizado de tr\u00eas em tr\u00eas anos para incorporar as mais recentes pr\u00e1ticas e tecnologias de conserva\u00e7\u00e3o de energia.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Porque Deve Importar-se<\/h3>\n\n<p>O IECC \u00e9 amplamente adotado por estados e munic\u00edpios em todo os Estados Unidos. O IECC abrange v\u00e1rios aspetos do uso de energia, incluindo a envolvente do edif\u00edcio (paredes, telhados e janelas), os sistemas de aquecimento e arrefecimento e os sistemas de ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O IECC exige controlos de ilumina\u00e7\u00e3o espec\u00edficos, tais como sensores de ocupa\u00e7\u00e3o, para minimizar o desperd\u00edcio de energia em espa\u00e7os desocupados em v\u00e1rias \u00e1reas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>A Norma ANSI\/ASHRAE\/IES 90.1, Norma Energ\u00e9tica para Locais e Edif\u00edcios Exceto Edif\u00edcios Residenciais de Baixa Altura, \u00e9 uma norma energ\u00e9tica amplamente reconhecida publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1: Porque deve importar-se<\/h3>\n\n<p>A ASHRAE 90.1 \u00e9 usada como refer\u00eancia para os c\u00f3digos energ\u00e9ticos de edif\u00edcios em todos os Estados Unidos e serve como via de conformidade no \u00e2mbito do IECC, que define requisitos m\u00ednimos para o desempenho energeticamente eficiente dos componentes dos edif\u00edcios comerciais, incluindo envolventes do edif\u00edcio, sistemas AVAC, sistemas de aquecimento de \u00e1gua e sistemas de ilumina\u00e7\u00e3o. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>A norma ASHRAE 90.1 especifica densidades m\u00e1ximas permitidas de pot\u00eancia de ilumina\u00e7\u00e3o e requisitos m\u00ednimos de controlo de ilumina\u00e7\u00e3o, incluindo a utiliza\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o em \u00e1reas espec\u00edficas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>O Title 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, \u00e9 administrado pela California Energy Commission e \u00e9 atualizado periodicamente para refletir novas tecnologias e m\u00e9todos de efici\u00eancia energ\u00e9tica.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24, Porque Deve Importar-se<\/h3>\n\n<p>O Title 24 \u00e9 conhecido pelos seus requisitos rigorosos, muitas vezes considerados mais exigentes do que os encontrados em muitos outros c\u00f3digos energ\u00e9ticos nos Estados Unidos. O Title 24 imp\u00f5e normas rigorosas de desempenho energ\u00e9tico para todos os aspetos da constru\u00e7\u00e3o de edif\u00edcios, incluindo aquecimento, ventila\u00e7\u00e3o, ar condicionado (HVAC), aquecimento de \u00e1gua e ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O Title 24 exige a instala\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o que ajustam a ilumina\u00e7\u00e3o com base na ocupa\u00e7\u00e3o das salas em \u00e1reas espec\u00edficas de edif\u00edcios comerciais, para garantir que a energia n\u00e3o \u00e9 desperdi\u00e7ada.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Ado\u00e7\u00e3o do c\u00f3digo energ\u00e9tico por estado<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expanda para ver a tabela detalhada \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Estado<\/th><th>C\u00f3digo comercial atual<\/th><th>Categoria de efici\u00eancia do c\u00f3digo comercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alasca<\/td><td>Nenhum a n\u00edvel estadual<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Arizona<\/td><td>Autonomia municipal<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Calif\u00f3rnia<\/td><td>Normas de Efici\u00eancia Energ\u00e9tica dos Edif\u00edcios 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distrito de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Fl\u00f3rida<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Ge\u00f3rgia<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Havai<\/td><td>Autonomia municipal<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Luisiana<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Nenhum a n\u00edvel estadual<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Missouri<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Novo M\u00e9xico<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nova Iorque<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Carolina do Norte<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota do Norte<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 e 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pensilv\u00e2nia<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Carolina do Sul<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota do Sul<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 e 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia Ocidental<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Quando uma altera\u00e7\u00e3o com impacto na efici\u00eancia energ\u00e9tica pode ser quantificada utilizando os Modelos de Edif\u00edcios Prot\u00f3tipo do DOE, foi inclu\u00edda na an\u00e1lise.<\/li>\n\n<li>Para os estados que adotam tanto o IECC como a 90.1, o c\u00f3digo IECC \u00e9 geralmente analisado como o c\u00f3digo estadual em vigor neste estudo, exceto para estados com altera\u00e7\u00f5es extensas ao IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solu\u00e7\u00f5es de Sensores<\/h4>\n\n<p>Descubra como a Rayzeek pode resolver os seus desafios de poupan\u00e7a de energia.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/pt\/produtos\"><div class=\"offering_button\"><p>Ver Todas as Ofertas<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-private-offices\">Conceitos-chave do guia de design para gabinetes privados<\/h2>\n\n<p>Conceber uma solu\u00e7\u00e3o de controlo de ilumina\u00e7\u00e3o eficiente em termos energ\u00e9ticos para gabinetes privados envolve a coloca\u00e7\u00e3o estrat\u00e9gica de sensores de ocupa\u00e7\u00e3o para garantir uma cobertura abrangente do espa\u00e7o.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-18029\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Numa arrecada\u00e7\u00e3o, as principais \u00e1reas que requerem ilumina\u00e7\u00e3o s\u00e3o os corredores principais e os corredores individuais entre as prateleiras. Eis algumas orienta\u00e7\u00f5es a seguir:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Corredores Principais<\/strong>: Instale sensores de ocupa\u00e7\u00e3o no teto a intervalos regulares ao longo dos principais percursos. Estes sensores devem ser configurados para o modo LIGAR autom\u00e1tico e DESLIGAR total, garantindo que as luzes se acendem automaticamente quando algu\u00e9m entra no percurso e se desligam quando a \u00e1rea fica desocupada.<\/li>\n\n<li><strong>Corredores Individuais<\/strong>: Para corredores individuais entre prateleiras, considere instalar sensores de ocupa\u00e7\u00e3o de parede na entrada de cada corredor. Estes sensores podem detetar quando algu\u00e9m entra no corredor e ligar as luzes em conformidade. Dada a utiliza\u00e7\u00e3o espor\u00e1dica destes corredores, os sensores devem ser configurados para o modo LIGAR manual e DESLIGAR total. Isto significa que as luzes s\u00f3 se acendem quando ligadas manualmente, mas desligam-se automaticamente quando o corredor estiver desocupado.<\/li>\n\n<li><strong>\u00c1rea de entrada<\/strong>: A zona de entrada da arrecada\u00e7\u00e3o deve ter um interruptor com sensor de parede que permita o controlo manual de toda a ilumina\u00e7\u00e3o na divis\u00e3o. Este interruptor pode ser utilizado para ligar ou desligar todas as luzes conforme necess\u00e1rio, proporcionando um n\u00edvel adicional de controlo.<\/li>\n\n<li><strong>Considera\u00e7\u00f5es sobre a Coloca\u00e7\u00e3o de Sensores<\/strong>: Ao colocar os sensores, assegure-se de que n\u00e3o ficam localizados perto de sa\u00eddas de ar ou de outras fontes de movimento que possam provocar falsos positivos. Al\u00e9m disso, garanta que o campo de vis\u00e3o dos sensores n\u00e3o \u00e9 obstru\u00eddo por prateleiras ou itens armazenados.<\/li>\n\n<li><strong>Altura do sensor<\/strong>: Considere a altura de instala\u00e7\u00e3o do sensor. Os sensores devem ser instalados a uma altura que permita uma cobertura ideal da divis\u00e3o, tendo em conta a altura dos itens armazenados.<\/li>\n\n<li><strong>Controlo Manual<\/strong>: Incorpore controlos manuais para permitir que os utilizadores liguem\/desliguem toda a ilumina\u00e7\u00e3o quando necess\u00e1rio. Isto pode ser particularmente \u00fatil em arrecada\u00e7\u00f5es onde a ilumina\u00e7\u00e3o pode ser necess\u00e1ria por per\u00edodos prolongados durante verifica\u00e7\u00f5es de invent\u00e1rio ou tarefas de reorganiza\u00e7\u00e3o.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produtos e solu\u00e7\u00f5es em destaque<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-movimento\/sensores-de-movimento-de-montagem-na-parede\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruptores com Sensor de Parede<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruptores com Sensor de Movimento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Op\u00e7\u00f5es de cablagem de 2 fios, 3 fios, 4 fios <\/li>\n\n<li>Ocupa\u00e7\u00e3o, Vazio, LIGAR\/DESLIGAR manual<\/li>\n\n<li>Atraso de tempo ajust\u00e1vel e controlo de luz ambiente<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-movimento-sem-fios\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Parede Sem Fios para V\u00e1rias Localiza\u00e7\u00f5es<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruptor com sensor de ocupa\u00e7\u00e3o com liga\u00e7\u00e3o fixa RZ021A\/022A<\/li>\n\n<li>Interruptor secund\u00e1rio sem fios (RZ022W) para controlo em v\u00e1rios locais<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-ocupacao\/montagem-no-teto\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de ocupa\u00e7\u00e3o de teto<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensores de ocupa\u00e7\u00e3o com liga\u00e7\u00e3o fixa<\/li>\n\n<li>LIGAR autom\u00e1tico, DESLIGAR autom\u00e1tico <\/li>\n\n<li>Dispon\u00edvel em tens\u00e3o de rede e baixa tens\u00e3o<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Funcionalidades principais inclu\u00eddas:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Controlo manual integrado LIGAR\/DESLIGAR para toda a ilumina\u00e7\u00e3o<\/li>\n\n<li>Sensores de aus\u00eancia (apenas LIGAR manual): As luzes devem ser ligadas apenas manualmente<\/li>\n\n<li>Atraso de tempo ajust\u00e1vel, a ilumina\u00e7\u00e3o desliga-se automaticamente por completo ap\u00f3s 15 min<\/li>\n\n<li>Adicional: kits sem fios multi-localiza\u00e7\u00e3o para expandir o alcance do controlo sem voltar a cablar<\/li>\n\n<li>Adicional: v\u00e1rias op\u00e7\u00f5es de cablagem dispon\u00edveis tanto para novas constru\u00e7\u00f5es como para projetos de remodela\u00e7\u00e3o.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18028\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Cumpre as Disposi\u00e7\u00f5es Obrigat\u00f3rias<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controlos por sensor de ocupa\u00e7\u00e3o<\/h4>\n\n<p>Devem ser instalados controlos por sensores de ocupantes para controlar as luzes no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fun\u00e7\u00f5es de controlo do sensor de ocupa\u00e7\u00e3o<\/h4>\n\n<ul class=\"wp-block-list\"><li>Liga\u00e7\u00e3o manual ou liga\u00e7\u00e3o parcial at\u00e9 n\u00e3o mais de 50% de pot\u00eancia.<\/li>\n\n<li>Desligamento total no prazo de 20 minutos ap\u00f3s todos os ocupantes terem sa\u00eddo do espa\u00e7o<\/li>\n\n<li>Um controlo manual para desligar as luzes.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Controlo local<\/h4>\n\n<p>Deve existir um ou mais dispositivos de controlo manual da ilumina\u00e7\u00e3o que forne\u00e7am controlo de LIGAR e DESLIGAR<br>de toda a ilumina\u00e7\u00e3o no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 H Controlo de DESLIGAR total autom\u00e1tico <\/h4>\n\n<p>Toda a ilumina\u00e7\u00e3o no espa\u00e7o deve desligar-se automaticamente no prazo de 20 minutos ap\u00f3s todos os ocupantes abandonarem o espa\u00e7o<\/p>\n\n<p>Adicionalmente, para arrecada\u00e7\u00f5es com dimens\u00f5es &lt;50 ft2:<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Restrito a LIGAR manual<\/h4>\n\n<p>Nenhuma ilumina\u00e7\u00e3o deve ser ligada automaticamente<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controlos manuais por \u00e1rea.<\/h4>\n\n<p>Cada \u00e1rea delimitada por divis\u00f3rias at\u00e9 \u00e0 altura do teto deve disponibilizar controlos de ilumina\u00e7\u00e3o que permitam que a ilumina\u00e7\u00e3o nessa \u00e1rea seja ligada e desligada manualmente.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controlos de DESLIGAR.<\/h4>\n\n<p>A ilumina\u00e7\u00e3o deve ser controlada com controlos de dete\u00e7\u00e3o de ocupantes para desligar automaticamente toda a ilumina\u00e7\u00e3o em 20 minutos ou menos ap\u00f3s a zona de controlo ficar desocupada, funcionando como:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Controlos por dete\u00e7\u00e3o de ocupantes (se 130.1(b) n\u00e3o exigir controlos de ilumina\u00e7\u00e3o multin\u00edvel); ou<\/li>\n\n<li>B. Controlos por dete\u00e7\u00e3o de ocupantes com LIGAR parcial; ou<\/li>\n\n<li>C. Controlos por dete\u00e7\u00e3o de aus\u00eancia (vacancy), em que toda a ilumina\u00e7\u00e3o responde apenas a uma entrada de LIGAR manual<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Queremos ouvi-lo.<\/h3>\n\n<p>Deixe a Rayzeek ajudar a conceber e fornecer uma solu\u00e7\u00e3o de ilumina\u00e7\u00e3o personalizada para poupan\u00e7a de energia.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pt\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"formul\u00e1rio de contacto\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/pt\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Enviar\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"pt\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>As salas de armazenamento, frequentemente negligenciadas, s\u00e3o partes integrantes dos edif\u00edcios comerciais. Estes espa\u00e7os est\u00e3o normalmente repletos de prateleiras, caixas e v\u00e1rios itens, e s\u00e3o utilizados para armazenar consum\u00edveis, equipamento ou documentos arquivados.<\/p>","protected":false},"author":1,"featured_media":18031,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18027","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Storage Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-arrecadacoes\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Storage Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-arrecadacoes\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide\",\"name\":\"Storage Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T09:12:15+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/storage-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Storage Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Storage Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-arrecadacoes","og_locale":"pt_PT","og_type":"article","og_title":"Storage Room Energy Code Design Guide - Rayzeek","og_description":"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.","og_url":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-arrecadacoes","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tempo estimado de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide","url":"https:\/\/www.rayzeek.com\/storage-room-design-guide","name":"Storage Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","datePublished":"2024-05-21T09:12:15+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/storage-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Storage Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/comments?post=18027"}],"version-history":[{"count":4,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18027\/revisions"}],"predecessor-version":[{"id":18153,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18027\/revisions\/18153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/media\/18031"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/media?parent=18027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}