{"id":18018,"date":"2024-05-21T09:01:51","date_gmt":"2024-05-21T09:01:51","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=18018"},"modified":"2024-06-05T02:22:35","modified_gmt":"2024-06-05T02:22:35","slug":"restroom-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-casas-de-banho","title":{"rendered":"Guia de design para casas de banho"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18024\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"restrooms\">Casas de banho<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Explore o nosso guia de poupan\u00e7a de energia para casas de banho, concebido para o ajudar a compreender e implementar solu\u00e7\u00f5es com sensores de ocupa\u00e7\u00e3o para um controlo de ilumina\u00e7\u00e3o eficiente, em conformidade com os C\u00f3digos de Energia dos EUA.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5.jpg\" alt=\"\" class=\"wp-image-18022\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-5-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-restrooms-with-occupancy-sensors\">Maximize a efici\u00eancia energ\u00e9tica em casas de banho com sensores de ocupa\u00e7\u00e3o<\/h2>\n\n<p>As casas de banho em edif\u00edcios comerciais s\u00e3o espa\u00e7os de uso frequente que muitas vezes permanecem iluminados mesmo quando est\u00e3o desocupados, levando a um desperd\u00edcio significativo de energia. Estes espa\u00e7os utilizam normalmente lumin\u00e1rias de ilumina\u00e7\u00e3o de alta intensidade que consomem quantidades substanciais de energia. A natureza espor\u00e1dica e imprevis\u00edvel da utiliza\u00e7\u00e3o das casas de banho agrava ainda mais este problema, uma vez que as luzes s\u00e3o frequentemente deixadas acesas desnecessariamente durante per\u00edodos de n\u00e3o utiliza\u00e7\u00e3o.<\/p>\n\n<p>Tendo em conta estes fatores, o potencial de poupan\u00e7a de energia em casas de banho \u00e9 substancial. Ao implementar solu\u00e7\u00f5es com sensores de ocupa\u00e7\u00e3o, as instala\u00e7\u00f5es comerciais podem reduzir significativamente o seu consumo de energia com ilumina\u00e7\u00e3o. Os sensores de ocupa\u00e7\u00e3o detetam a presen\u00e7a ou aus\u00eancia de pessoas e controlam automaticamente a ilumina\u00e7\u00e3o em conformidade, garantindo que as luzes est\u00e3o acesas apenas quando necess\u00e1rio. Isto n\u00e3o s\u00f3 poupa energia, como tamb\u00e9m prolonga a vida \u00fatil das lumin\u00e1rias, gerando poupan\u00e7as adicionais de custos.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Conhe\u00e7a os C\u00f3digos de Energia<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>O International Energy Conservation Code (IECC) \u00e9 um c\u00f3digo-modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos m\u00ednimos de conce\u00e7\u00e3o e constru\u00e7\u00e3o para a efici\u00eancia energ\u00e9tica nos edif\u00edcios. O IECC \u00e9 atualizado de tr\u00eas em tr\u00eas anos para incorporar as mais recentes pr\u00e1ticas e tecnologias de conserva\u00e7\u00e3o de energia.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Porque Deve Importar-se<\/h3>\n\n<p>O IECC \u00e9 amplamente adotado por estados e munic\u00edpios em todo os Estados Unidos. O IECC abrange v\u00e1rios aspetos do uso de energia, incluindo a envolvente do edif\u00edcio (paredes, telhados e janelas), os sistemas de aquecimento e arrefecimento e os sistemas de ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O IECC exige controlos de ilumina\u00e7\u00e3o espec\u00edficos, tais como sensores de ocupa\u00e7\u00e3o, para minimizar o desperd\u00edcio de energia em espa\u00e7os desocupados em v\u00e1rias \u00e1reas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>A Norma ANSI\/ASHRAE\/IES 90.1, Norma Energ\u00e9tica para Locais e Edif\u00edcios Exceto Edif\u00edcios Residenciais de Baixa Altura, \u00e9 uma norma energ\u00e9tica amplamente reconhecida publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1: Porque deve importar-se<\/h3>\n\n<p>A ASHRAE 90.1 \u00e9 usada como refer\u00eancia para os c\u00f3digos energ\u00e9ticos de edif\u00edcios em todos os Estados Unidos e serve como via de conformidade no \u00e2mbito do IECC, que define requisitos m\u00ednimos para o desempenho energeticamente eficiente dos componentes dos edif\u00edcios comerciais, incluindo envolventes do edif\u00edcio, sistemas AVAC, sistemas de aquecimento de \u00e1gua e sistemas de ilumina\u00e7\u00e3o. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>A norma ASHRAE 90.1 especifica densidades m\u00e1ximas permitidas de pot\u00eancia de ilumina\u00e7\u00e3o e requisitos m\u00ednimos de controlo de ilumina\u00e7\u00e3o, incluindo a utiliza\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o em \u00e1reas espec\u00edficas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>O Title 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, \u00e9 administrado pela California Energy Commission e \u00e9 atualizado periodicamente para refletir novas tecnologias e m\u00e9todos de efici\u00eancia energ\u00e9tica.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24, Porque Deve Importar-se<\/h3>\n\n<p>O Title 24 \u00e9 conhecido pelos seus requisitos rigorosos, muitas vezes considerados mais exigentes do que os encontrados em muitos outros c\u00f3digos energ\u00e9ticos nos Estados Unidos. O Title 24 imp\u00f5e normas rigorosas de desempenho energ\u00e9tico para todos os aspetos da constru\u00e7\u00e3o de edif\u00edcios, incluindo aquecimento, ventila\u00e7\u00e3o, ar condicionado (HVAC), aquecimento de \u00e1gua e ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O Title 24 exige a instala\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o que ajustam a ilumina\u00e7\u00e3o com base na ocupa\u00e7\u00e3o das salas em \u00e1reas espec\u00edficas de edif\u00edcios comerciais, para garantir que a energia n\u00e3o \u00e9 desperdi\u00e7ada.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Ado\u00e7\u00e3o do c\u00f3digo energ\u00e9tico por estado<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expanda para ver a tabela detalhada \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Estado<\/th><th>C\u00f3digo comercial atual<\/th><th>Categoria de efici\u00eancia do c\u00f3digo comercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alasca<\/td><td>Nenhum a n\u00edvel estadual<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Arizona<\/td><td>Autonomia municipal<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Calif\u00f3rnia<\/td><td>Normas de Efici\u00eancia Energ\u00e9tica dos Edif\u00edcios 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distrito de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Fl\u00f3rida<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Ge\u00f3rgia<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Havai<\/td><td>Autonomia municipal<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Luisiana<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Nenhum a n\u00edvel estadual<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Missouri<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Novo M\u00e9xico<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nova Iorque<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Carolina do Norte<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota do Norte<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 e 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pensilv\u00e2nia<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Carolina do Sul<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota do Sul<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 e 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia Ocidental<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Quando uma altera\u00e7\u00e3o com impacto na efici\u00eancia energ\u00e9tica pode ser quantificada utilizando os Modelos de Edif\u00edcios Prot\u00f3tipo do DOE, foi inclu\u00edda na an\u00e1lise.<\/li>\n\n<li>Para os estados que adotam tanto o IECC como a 90.1, o c\u00f3digo IECC \u00e9 geralmente analisado como o c\u00f3digo estadual em vigor neste estudo, exceto para estados com altera\u00e7\u00f5es extensas ao IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solu\u00e7\u00f5es de Sensores<\/h4>\n\n<p>Descubra como a Rayzeek pode resolver os seus desafios de poupan\u00e7a de energia.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/pt\/produtos\"><div class=\"offering_button\"><p>Ver Todas as Ofertas<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-restrooms\">Conceitos-chave do guia de conce\u00e7\u00e3o para casas de banho<\/h2>\n\n<p>Conceber uma solu\u00e7\u00e3o de controlo de ilumina\u00e7\u00e3o energeticamente eficiente para casas de banho envolve a coloca\u00e7\u00e3o estrat\u00e9gica de sensores de ocupa\u00e7\u00e3o para garantir uma cobertura abrangente do espa\u00e7o.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18019\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Ao seguir estas diretrizes, as empresas podem criar uma solu\u00e7\u00e3o de controlo de ilumina\u00e7\u00e3o energeticamente eficiente para casas de banho que reduz o desperd\u00edcio de energia e diminui os custos de manuten\u00e7\u00e3o:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Cobertura da entrada<\/strong>: Instale um sensor de ocupa\u00e7\u00e3o de parede junto \u00e0 entrada para detetar quando algu\u00e9m entra na casa de banho. Este sensor deve ser posicionado suficientemente alto para evitar obstru\u00e7\u00f5es pela porta e n\u00e3o deve estar diretamente voltado para a entrada, para evitar ativa\u00e7\u00f5es falsas devido a movimento fora da casa de banho.<\/li>\n\n<li><strong>Cobertura das Cabines<\/strong>: Dependendo da prefer\u00eancia do cliente relativamente \u00e0 privacidade, as cabines podem estar cobertas por um sensor ou n\u00e3o. Se as cabines n\u00e3o estiverem cobertas por um sensor, programe um tempo de espera mais longo (15 ou 20 minutos) para evitar que as luzes se desliguem quando algu\u00e9m estiver na cabine. Se forem utilizados sensores individuais por cabine, devem ser instalados de forma a n\u00e3o detetarem movimento fora da cabine, para evitar ativa\u00e7\u00f5es falsas.<\/li>\n\n<li><strong>\u00c1rea do Lavat\u00f3rio e do Espelho<\/strong>: Instale um sensor de ocupa\u00e7\u00e3o no teto acima da \u00e1rea do lavat\u00f3rio e do espelho. Este sensor deve ser posicionado para cobrir toda a \u00e1rea, garantindo que as luzes permanecem acesas quando algu\u00e9m est\u00e1 a utilizar o lavat\u00f3rio ou o espelho.<\/li>\n\n<li><strong>Evitar sa\u00eddas de ar<\/strong>: N\u00e3o monte sensores perto de sa\u00eddas de ar, pois a vibra\u00e7\u00e3o e o fluxo de ar podem reduzir a efic\u00e1cia do sensor. Os sensores PIR n\u00e3o devem estar a menos de 4 ft de uma sa\u00edda de ar e os sensores ultrass\u00f3nicos n\u00e3o devem estar a menos de 6 ft de uma sa\u00edda de ar.<\/li>\n\n<li><strong>Controlo Manual<\/strong>: Integre controlo manual para ligar\/desligar toda a ilumina\u00e7\u00e3o com os nossos sensores de ocupa\u00e7\u00e3o\/vac\u00e2ncia. Isto permite a substitui\u00e7\u00e3o manual do sistema de ilumina\u00e7\u00e3o, se necess\u00e1rio.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produtos e solu\u00e7\u00f5es em destaque<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-movimento\/sensores-de-movimento-de-montagem-na-parede\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruptores com Sensor de Parede<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruptores com Sensor de Movimento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Op\u00e7\u00f5es de cablagem de 2 fios, 3 fios, 4 fios <\/li>\n\n<li>Ocupa\u00e7\u00e3o, Vazio, LIGAR\/DESLIGAR manual<\/li>\n\n<li>Atraso de tempo ajust\u00e1vel e controlo de luz ambiente<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-movimento-sem-fios\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Parede Sem Fios para V\u00e1rias Localiza\u00e7\u00f5es<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruptor com sensor de ocupa\u00e7\u00e3o com liga\u00e7\u00e3o fixa RZ021A\/022A<\/li>\n\n<li>Interruptor secund\u00e1rio sem fios (RZ022W) para controlo em v\u00e1rios locais<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-ocupacao\/montagem-no-teto\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de ocupa\u00e7\u00e3o de teto<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensores de ocupa\u00e7\u00e3o com liga\u00e7\u00e3o fixa<\/li>\n\n<li>LIGAR autom\u00e1tico, DESLIGAR autom\u00e1tico <\/li>\n\n<li>Dispon\u00edvel em tens\u00e3o de rede e baixa tens\u00e3o<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Funcionalidades principais inclu\u00eddas:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Controlo manual integrado LIGAR\/DESLIGAR para toda a ilumina\u00e7\u00e3o<\/li>\n\n<li>Sensores de aus\u00eancia (apenas LIGAR manual): As luzes devem ser ligadas apenas manualmente<\/li>\n\n<li>Atraso de tempo ajust\u00e1vel, a ilumina\u00e7\u00e3o desliga-se automaticamente por completo ap\u00f3s 15 min<\/li>\n\n<li>Adicional: kits sem fios multi-localiza\u00e7\u00e3o para expandir o alcance do controlo sem voltar a cablar<\/li>\n\n<li>Adicional: v\u00e1rias op\u00e7\u00f5es de cablagem dispon\u00edveis tanto para novas constru\u00e7\u00f5es como para projetos de remodela\u00e7\u00e3o.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6.jpg\" alt=\"\" class=\"wp-image-18023\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-6-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Cumpre as Disposi\u00e7\u00f5es Obrigat\u00f3rias<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controlos por sensor de ocupa\u00e7\u00e3o<\/h4>\n\n<p>Devem ser instalados controlos por sensores de ocupantes para controlar as luzes no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fun\u00e7\u00f5es de controlo do sensor de ocupa\u00e7\u00e3o<\/h4>\n\n<ul class=\"wp-block-list\"><li>Liga\u00e7\u00e3o manual ou liga\u00e7\u00e3o parcial at\u00e9 n\u00e3o mais de 50% de pot\u00eancia.<\/li>\n\n<li>Desligamento total no prazo de 20 minutos ap\u00f3s todos os ocupantes terem sa\u00eddo do espa\u00e7o<\/li>\n\n<li>Um controlo manual para desligar as luzes.<\/li><\/ul>\n\n<p>**S\u00e3o permitidos controlos totalmente autom\u00e1ticos de ligar, sem controlo manual, em casas de banho onde a opera\u00e7\u00e3o manual colocaria em risco a seguran\u00e7a ou a prote\u00e7\u00e3o dos ocupantes.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<p>As casas de banho tamb\u00e9m devem ser controladas por sensores de ocupantes.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 H Controlo de DESLIGAR total autom\u00e1tico <\/h4>\n\n<p>Toda a ilumina\u00e7\u00e3o no espa\u00e7o deve desligar-se automaticamente no prazo de 20 minutos ap\u00f3s todos os ocupantes abandonarem o espa\u00e7o<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controlos manuais por \u00e1rea.<\/h4>\n\n<p>Cada \u00e1rea delimitada por divis\u00f3rias at\u00e9 \u00e0 altura do teto deve disponibilizar controlos de ilumina\u00e7\u00e3o que permitam que a ilumina\u00e7\u00e3o nessa \u00e1rea seja ligada e desligada manualmente.<\/p>\n\n<p>** As casas de banho com duas ou mais cabines podem utilizar um controlo manual n\u00e3o acess\u00edvel a pessoal n\u00e3o autorizado.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controlos de DESLIGAR.<\/h4>\n\n<p>A ilumina\u00e7\u00e3o deve ser controlada com controlos de dete\u00e7\u00e3o de ocupantes para desligar automaticamente toda a ilumina\u00e7\u00e3o em 20 minutos ou menos ap\u00f3s a zona de controlo ficar desocupada, funcionando como:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Controlos por dete\u00e7\u00e3o de ocupantes (se 130.1(b) n\u00e3o exigir controlos de ilumina\u00e7\u00e3o multin\u00edvel); ou<\/li>\n\n<li>B. Controlos por dete\u00e7\u00e3o de ocupantes com LIGAR parcial; ou<\/li>\n\n<li>C. Controlos por dete\u00e7\u00e3o de aus\u00eancia (vacancy), em que toda a ilumina\u00e7\u00e3o responde apenas a uma entrada de LIGAR manual<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Queremos ouvi-lo.<\/h3>\n\n<p>Deixe a Rayzeek ajudar a conceber e fornecer uma solu\u00e7\u00e3o de ilumina\u00e7\u00e3o personalizada para poupan\u00e7a de energia.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pt\/wp-json\/wp\/v2\/pages\/18018#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"formul\u00e1rio de contacto\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/pt\/wp-json\/wp\/v2\/pages\/18018#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Enviar\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"pt\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>As casas de banho em edif\u00edcios comerciais s\u00e3o espa\u00e7os de uso frequente que muitas vezes permanecem iluminados mesmo quando est\u00e3o desocupados, levando a um desperd\u00edcio significativo de energia. Estes espa\u00e7os utilizam normalmente lumin\u00e1rias de ilumina\u00e7\u00e3o de alta intensidade que consomem quantidades substanciais de energia.<\/p>","protected":false},"author":1,"featured_media":18024,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18018","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Restroom Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-casas-de-banho\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Restroom Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-casas-de-banho\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/restroom-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/restroom-design-guide\",\"name\":\"Restroom Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/restroom-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/restroom-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T09:01:51+00:00\",\"dateModified\":\"2024-06-05T02:22:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/restroom-design-guide#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/restroom-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/www.rayzeek.com\/restroom-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/restroom-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Restroom Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Restroom Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-casas-de-banho","og_locale":"pt_PT","og_type":"article","og_title":"Restroom Energy Code Design Guide - Rayzeek","og_description":"Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy.","og_url":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-casas-de-banho","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:35+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tempo estimado de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/restroom-design-guide","url":"https:\/\/www.rayzeek.com\/restroom-design-guide","name":"Restroom Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/restroom-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/restroom-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","datePublished":"2024-05-21T09:01:51+00:00","dateModified":"2024-06-05T02:22:35+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/restroom-design-guide#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/restroom-design-guide"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.rayzeek.com\/restroom-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/restroom-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/restroom-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Restroom Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/comments?post=18018"}],"version-history":[{"count":8,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18018\/revisions"}],"predecessor-version":[{"id":18154,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18018\/revisions\/18154"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/media\/18024"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/media?parent=18018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}