{"id":18011,"date":"2024-05-21T08:52:43","date_gmt":"2024-05-21T08:52:43","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=18011"},"modified":"2024-06-05T02:22:30","modified_gmt":"2024-06-05T02:22:30","slug":"classroom-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-salas-de-aula","title":{"rendered":"Guia de design para salas de aula"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18016\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"classrooms\">Salas de aula<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Descubra o potencial de poupan\u00e7a de energia das salas de aula com o guia de design de sensores de ocupa\u00e7\u00e3o da Rayzeek. Saiba como cumprir os requisitos dos c\u00f3digos energ\u00e9ticos, criando simultaneamente um ambiente de aprendizagem mais eficiente.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1.jpg\" alt=\"\" class=\"wp-image-18012\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-1-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"transforming-classrooms-into-energyefficient-learning-spaces\">Transformar Salas de Aula em Espa\u00e7os de Aprendizagem Energeticamente Eficientes<\/h2>\n\n<p>As salas de aula s\u00e3o espa\u00e7os din\u00e2micos que servem de base \u00e0 aprendizagem e ao desenvolvimento. Est\u00e3o frequentemente equipadas com uma variedade de lumin\u00e1rias, desde luzes de teto a ilumina\u00e7\u00e3o de tarefa, o que contribui para um consumo de energia significativo. A ilumina\u00e7\u00e3o nestes espa\u00e7os \u00e9 normalmente deixada ligada por per\u00edodos prolongados, mesmo quando a sala est\u00e1 desocupada, levando a um desperd\u00edcio de energia desnecess\u00e1rio.<\/p>\n\n<p>Numa sala de aula t\u00edpica, as necessidades de ilumina\u00e7\u00e3o podem variar bastante consoante a hora do dia, as atividades que decorrem e o n\u00famero de ocupantes. Esta variabilidade torna dif\u00edcil gerir a ilumina\u00e7\u00e3o de forma eficaz e eficiente. Como resultado, existe uma necessidade premente de solu\u00e7\u00f5es que possam controlar automaticamente a ilumina\u00e7\u00e3o com base na ocupa\u00e7\u00e3o, reduzindo assim o consumo de energia desnecess\u00e1rio.<\/p>\n\n<p>A necessidade de conserva\u00e7\u00e3o de energia nas salas de aula \u00e9 evidente, e uma das solu\u00e7\u00f5es mais eficazes \u00e9 a utiliza\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o. Estes dispositivos podem desligar automaticamente as luzes quando uma sala est\u00e1 vazia, reduzindo significativamente o consumo de energia. Com a gama de sensores de ocupa\u00e7\u00e3o da Rayzeek, as salas de aula podem tornar-se mais eficientes em termos energ\u00e9ticos, cumprindo os requisitos dos c\u00f3digos de energia e reduzindo tamb\u00e9m os custos operacionais.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Conhe\u00e7a os C\u00f3digos de Energia<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>O International Energy Conservation Code (IECC) \u00e9 um c\u00f3digo-modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos m\u00ednimos de conce\u00e7\u00e3o e constru\u00e7\u00e3o para a efici\u00eancia energ\u00e9tica nos edif\u00edcios. O IECC \u00e9 atualizado de tr\u00eas em tr\u00eas anos para incorporar as mais recentes pr\u00e1ticas e tecnologias de conserva\u00e7\u00e3o de energia.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, Porque Deve Importar-se<\/h3>\n\n<p>O IECC \u00e9 amplamente adotado por estados e munic\u00edpios em todo os Estados Unidos. O IECC abrange v\u00e1rios aspetos do uso de energia, incluindo a envolvente do edif\u00edcio (paredes, telhados e janelas), os sistemas de aquecimento e arrefecimento e os sistemas de ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O IECC exige controlos de ilumina\u00e7\u00e3o espec\u00edficos, tais como sensores de ocupa\u00e7\u00e3o, para minimizar o desperd\u00edcio de energia em espa\u00e7os desocupados em v\u00e1rias \u00e1reas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>A Norma ANSI\/ASHRAE\/IES 90.1, Norma Energ\u00e9tica para Locais e Edif\u00edcios Exceto Edif\u00edcios Residenciais de Baixa Altura, \u00e9 uma norma energ\u00e9tica amplamente reconhecida publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1: Porque deve importar-se<\/h3>\n\n<p>A ASHRAE 90.1 \u00e9 usada como refer\u00eancia para os c\u00f3digos energ\u00e9ticos de edif\u00edcios em todos os Estados Unidos e serve como via de conformidade no \u00e2mbito do IECC, que define requisitos m\u00ednimos para o desempenho energeticamente eficiente dos componentes dos edif\u00edcios comerciais, incluindo envolventes do edif\u00edcio, sistemas AVAC, sistemas de aquecimento de \u00e1gua e sistemas de ilumina\u00e7\u00e3o. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>A norma ASHRAE 90.1 especifica densidades m\u00e1ximas permitidas de pot\u00eancia de ilumina\u00e7\u00e3o e requisitos m\u00ednimos de controlo de ilumina\u00e7\u00e3o, incluindo a utiliza\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o em \u00e1reas espec\u00edficas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>O Title 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, \u00e9 administrado pela California Energy Commission e \u00e9 atualizado periodicamente para refletir novas tecnologias e m\u00e9todos de efici\u00eancia energ\u00e9tica.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24, Porque Deve Importar-se<\/h3>\n\n<p>O Title 24 \u00e9 conhecido pelos seus requisitos rigorosos, muitas vezes considerados mais exigentes do que os encontrados em muitos outros c\u00f3digos energ\u00e9ticos nos Estados Unidos. O Title 24 imp\u00f5e normas rigorosas de desempenho energ\u00e9tico para todos os aspetos da constru\u00e7\u00e3o de edif\u00edcios, incluindo aquecimento, ventila\u00e7\u00e3o, ar condicionado (HVAC), aquecimento de \u00e1gua e ilumina\u00e7\u00e3o.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>O Title 24 exige a instala\u00e7\u00e3o de sensores de ocupa\u00e7\u00e3o que ajustam a ilumina\u00e7\u00e3o com base na ocupa\u00e7\u00e3o das salas em \u00e1reas espec\u00edficas de edif\u00edcios comerciais, para garantir que a energia n\u00e3o \u00e9 desperdi\u00e7ada.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Ado\u00e7\u00e3o do c\u00f3digo energ\u00e9tico por estado<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expanda para ver a tabela detalhada \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Estado<\/th><th>C\u00f3digo comercial atual<\/th><th>Categoria de efici\u00eancia do c\u00f3digo comercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alasca<\/td><td>Nenhum a n\u00edvel estadual<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Arizona<\/td><td>Autonomia municipal<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Calif\u00f3rnia<\/td><td>Normas de Efici\u00eancia Energ\u00e9tica dos Edif\u00edcios 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distrito de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Fl\u00f3rida<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Ge\u00f3rgia<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Havai<\/td><td>Autonomia municipal<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Luisiana<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Nenhum a n\u00edvel estadual<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Missouri<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Novo M\u00e9xico<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nova Iorque<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Carolina do Norte<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota do Norte<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 e 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pensilv\u00e2nia<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Carolina do Sul<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota do Sul<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 e 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico do Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virg\u00ednia Ocidental<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonomia municipal<\/td><td>Sem c\u00f3digo a n\u00edvel estadual<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Quando uma altera\u00e7\u00e3o com impacto na efici\u00eancia energ\u00e9tica pode ser quantificada utilizando os Modelos de Edif\u00edcios Prot\u00f3tipo do DOE, foi inclu\u00edda na an\u00e1lise.<\/li>\n\n<li>Para os estados que adotam tanto o IECC como a 90.1, o c\u00f3digo IECC \u00e9 geralmente analisado como o c\u00f3digo estadual em vigor neste estudo, exceto para estados com altera\u00e7\u00f5es extensas ao IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solu\u00e7\u00f5es de Sensores<\/h4>\n\n<p>Descubra como a Rayzeek pode resolver os seus desafios de poupan\u00e7a de energia.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/pt\/produtos\"><div class=\"offering_button\"><p>Ver Todas as Ofertas<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-classrooms\">Conceitos-chave do guia de design para salas de aula<\/h2>\n\n<p>Conceber uma solu\u00e7\u00e3o de controlo de ilumina\u00e7\u00e3o energeticamente eficiente para salas de aula envolve a coloca\u00e7\u00e3o estrat\u00e9gica de sensores de ocupa\u00e7\u00e3o para garantir uma cobertura abrangente do espa\u00e7o.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4.jpg\" alt=\"\" class=\"wp-image-18015\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Conceber uma sala de aula energeticamente eficiente com sensores de ocupa\u00e7\u00e3o envolve um planeamento cuidadoso e a coloca\u00e7\u00e3o estrat\u00e9gica dos sensores:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Sensores de Ocupa\u00e7\u00e3o\/Aus\u00eancia de Parede<\/strong>: Instale estes sensores perto da entrada principal da sala de aula. Estes sensores conseguem detetar quando algu\u00e9m entra ou sai da sala e podem ligar ou desligar automaticamente as luzes em conformidade. Tamb\u00e9m podem ser controlados manualmente para ligar ou desligar todas as luzes.<\/li>\n\n<li><strong>Sensores de ocupa\u00e7\u00e3o de teto<\/strong>: Estes sensores devem ser instalados no centro da sala de aula, garantindo uma vis\u00e3o desimpedida de toda a sala para cobrir \u00e1reas-chave, como a secret\u00e1ria do professor, as secret\u00e1rias dos alunos e quaisquer \u00e1reas de aprendizagem separadas. Podem detetar qualquer movimento na sala, incluindo movimentos ligeiros, como alunos a escrever nas suas secret\u00e1rias. Quando n\u00e3o for detetado movimento durante um per\u00edodo definido, as luzes desligar-se-\u00e3o automaticamente.<\/li>\n\n<li><strong>Sensores adicionais para \u00e1reas espec\u00edficas<\/strong>: Se a sala de aula tiver \u00e1reas espec\u00edficas, como um canto de leitura ou uma \u00e1rea de laborat\u00f3rio, poder\u00e3o ser necess\u00e1rios sensores adicionais. Estes sensores podem controlar a ilumina\u00e7\u00e3o dessas \u00e1reas espec\u00edficas com base na ocupa\u00e7\u00e3o, garantindo que as luzes n\u00e3o ficam acesas desnecessariamente.<\/li>\n\n<li><strong>Considera\u00e7\u00f5es sobre a Coloca\u00e7\u00e3o de Sensores<\/strong>: Evite colocar sensores perto de sa\u00eddas de ar ou outras fontes de movimento que possam acionar o sensor indevidamente. Al\u00e9m disso, assegure-se de que a vis\u00e3o dos sensores n\u00e3o \u00e9 obstru\u00edda por mobili\u00e1rio alto ou equipamentos.<\/li>\n\n<li><strong>Considera\u00e7\u00e3o da luz natural<\/strong>: Se a sala de aula tiver janelas, os sensores devem ser programados para ter em conta a luz natural que entra na sala. Isto pode ajudar a reduzir ainda mais o consumo de energia, aproveitando a luz natural sempre que poss\u00edvel.<\/li>\n\n<li><strong>Integra\u00e7\u00e3o com Controlo Manual<\/strong>: Todos os sensores de ocupa\u00e7\u00e3o\/vac\u00e2ncia devem ser integrados com controlos manuais. Isto permite que os professores desliguem manualmente as luzes durante atividades como apresenta\u00e7\u00f5es de v\u00eddeo, mesmo que a sala esteja ocupada.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produtos e solu\u00e7\u00f5es em destaque<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-movimento\/sensores-de-movimento-de-montagem-na-parede\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruptores com Sensor de Parede<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruptores com Sensor de Movimento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Op\u00e7\u00f5es de cablagem de 2 fios, 3 fios, 4 fios <\/li>\n\n<li>Ocupa\u00e7\u00e3o, Vazio, LIGAR\/DESLIGAR manual<\/li>\n\n<li>Atraso de tempo ajust\u00e1vel e controlo de luz ambiente<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-movimento-sem-fios\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de Parede Sem Fios para V\u00e1rias Localiza\u00e7\u00f5es<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruptor com sensor de ocupa\u00e7\u00e3o com liga\u00e7\u00e3o fixa RZ021A\/022A<\/li>\n\n<li>Interruptor secund\u00e1rio sem fios (RZ022W) para controlo em v\u00e1rios locais<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pt\/categoria-de-produto\/sensores-de-ocupacao\/montagem-no-teto\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de ocupa\u00e7\u00e3o de teto<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensores de ocupa\u00e7\u00e3o com liga\u00e7\u00e3o fixa<\/li>\n\n<li>LIGAR autom\u00e1tico, DESLIGAR autom\u00e1tico <\/li>\n\n<li>Dispon\u00edvel em tens\u00e3o de rede e baixa tens\u00e3o<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Funcionalidades principais inclu\u00eddas:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Controlo manual integrado LIGAR\/DESLIGAR para toda a ilumina\u00e7\u00e3o<\/li>\n\n<li>Sensores de aus\u00eancia (apenas LIGAR manual): As luzes devem ser ligadas apenas manualmente<\/li>\n\n<li>Atraso de tempo ajust\u00e1vel, a ilumina\u00e7\u00e3o desliga-se automaticamente por completo ap\u00f3s 15 min<\/li>\n\n<li>Adicional: kits sem fios multi-localiza\u00e7\u00e3o para expandir o alcance do controlo sem voltar a cablar<\/li>\n\n<li>Adicional: v\u00e1rias op\u00e7\u00f5es de cablagem dispon\u00edveis tanto para novas constru\u00e7\u00f5es como para projetos de remodela\u00e7\u00e3o.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18013\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Cumpre as Disposi\u00e7\u00f5es Obrigat\u00f3rias<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controlos por sensor de ocupa\u00e7\u00e3o<\/h4>\n\n<p>Devem ser instalados controlos por sensores de ocupantes para controlar as luzes no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fun\u00e7\u00f5es de controlo do sensor de ocupa\u00e7\u00e3o<\/h4>\n\n<ul class=\"wp-block-list\"><li>Liga\u00e7\u00e3o manual ou liga\u00e7\u00e3o parcial at\u00e9 n\u00e3o mais de 50% de pot\u00eancia.<\/li>\n\n<li>Desligamento total no prazo de 20 minutos ap\u00f3s todos os ocupantes terem sa\u00eddo do espa\u00e7o<\/li>\n\n<li>Um controlo manual para desligar as luzes.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Controlo local<\/h4>\n\n<p>Deve existir um ou mais dispositivos de controlo manual da ilumina\u00e7\u00e3o que forne\u00e7am controlo de LIGAR e DESLIGAR<br>de toda a ilumina\u00e7\u00e3o no espa\u00e7o.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Restrito a LIGAR manual<\/h4>\n\n<p>Nenhuma ilumina\u00e7\u00e3o deve ser ligada automaticamente<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-c-restricted-to-partial-automatic-on\">9.4.1.1 c Restrito a LIGAR autom\u00e1tico parcial<\/h4>\n\n<p>N\u00e3o \u00e9 permitido que mais de 50% da pot\u00eancia de ilumina\u00e7\u00e3o da ilumina\u00e7\u00e3o geral seja ligada automaticamente<\/p>\n\n<p>** NOTA: Deve ser implementado pelo menos um dos itens 9.4.1.1 b ou 9.4.1.1 c.<\/p>\n\n<p>Para salas de aula, exceto salas de oficina (todas as outras salas de aula\/anfiteatros\/salas de forma\u00e7\u00e3o):<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Controlo de DESLIGAR total autom\u00e1tico <\/h4>\n\n<p>Toda a ilumina\u00e7\u00e3o no espa\u00e7o deve desligar-se automaticamente no prazo de 20 minutos ap\u00f3s todos os ocupantes abandonarem o espa\u00e7o<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controlos manuais por \u00e1rea.<\/h4>\n\n<p>Cada \u00e1rea delimitada por divis\u00f3rias at\u00e9 \u00e0 altura do teto deve disponibilizar controlos de ilumina\u00e7\u00e3o que permitam que a ilumina\u00e7\u00e3o nessa \u00e1rea seja ligada e desligada manualmente.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controlos de DESLIGAR.<\/h4>\n\n<p>A ilumina\u00e7\u00e3o deve ser controlada com controlos de dete\u00e7\u00e3o de ocupantes para desligar automaticamente toda a ilumina\u00e7\u00e3o em 20 minutos ou menos ap\u00f3s a zona de controlo ficar desocupada, funcionando como:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Controlos por dete\u00e7\u00e3o de ocupantes (se 130.1(b) n\u00e3o exigir controlos de ilumina\u00e7\u00e3o multin\u00edvel); ou<\/li>\n\n<li>B. Controlos por dete\u00e7\u00e3o de ocupantes com LIGAR parcial; ou<\/li>\n\n<li>C. Controlos por dete\u00e7\u00e3o de aus\u00eancia (vacancy), em que toda a ilumina\u00e7\u00e3o responde apenas a uma entrada de LIGAR manual<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Queremos ouvi-lo.<\/h3>\n\n<p>Deixe a Rayzeek ajudar a conceber e fornecer uma solu\u00e7\u00e3o de ilumina\u00e7\u00e3o personalizada para poupan\u00e7a de energia.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pt\/wp-json\/wp\/v2\/pages\/18011#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"formul\u00e1rio de contacto\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/pt\/wp-json\/wp\/v2\/pages\/18011#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Enviar\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"pt\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>As salas de aula s\u00e3o espa\u00e7os din\u00e2micos que servem de base \u00e0 aprendizagem e ao desenvolvimento. Est\u00e3o frequentemente equipadas com uma variedade de lumin\u00e1rias, desde luzes de teto a ilumina\u00e7\u00e3o de tarefa, o que contribui para um consumo de energia significativo.<\/p>","protected":false},"author":1,"featured_media":18016,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18011","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Classroom Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-salas-de-aula\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Classroom Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-salas-de-aula\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/classroom-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/classroom-design-guide\",\"name\":\"Classroom Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/classroom-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/classroom-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:52:43+00:00\",\"dateModified\":\"2024-06-05T02:22:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/classroom-design-guide#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/classroom-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/www.rayzeek.com\/classroom-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/classroom-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Classroom Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Classroom Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-salas-de-aula","og_locale":"pt_PT","og_type":"article","og_title":"Classroom Energy Code Design Guide - Rayzeek","og_description":"Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption.","og_url":"https:\/\/www.rayzeek.com\/pt\/guia-de-concecao-de-salas-de-aula","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:30+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tempo estimado de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/classroom-design-guide","url":"https:\/\/www.rayzeek.com\/classroom-design-guide","name":"Classroom Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/classroom-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/classroom-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg","datePublished":"2024-05-21T08:52:43+00:00","dateModified":"2024-06-05T02:22:30+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/classroom-design-guide#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/classroom-design-guide"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.rayzeek.com\/classroom-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/classroom-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/classroom-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Classroom Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18011","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/comments?post=18011"}],"version-history":[{"count":13,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18011\/revisions"}],"predecessor-version":[{"id":18160,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/pages\/18011\/revisions\/18160"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/media\/18016"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/pt\/wp-json\/wp\/v2\/media?parent=18011"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}