{"id":18027,"date":"2024-05-21T09:12:15","date_gmt":"2024-05-21T09:12:15","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=18027"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"storage-room-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/pl\/przewodnik-projektowania-przechowalni","title":{"rendered":"Przewodnik projektowania magazynu"},"content":{"rendered":"<div class=\"wp-block-cover alignfull rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18031\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"storage-rooms\">pomieszczenia magazynowe<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Odkryj potencja\u0142 oszcz\u0119dzania energii w magazynach dzi\u0119ki przewodnikowi projektowemu Rayzeek dotycz\u0105cemu czujnik\u00f3w obecno\u015bci.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg\" alt=\"\" class=\"wp-image-18030\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-storage-rooms-with-occupancy-sensors\">Maksymalizuj efektywno\u015b\u0107 energetyczn\u0105 w magazynach dzi\u0119ki czujnikom obecno\u015bci<\/h2>\n\n<p>Pomieszczenia magazynowe, cz\u0119sto pomijane, s\u0105 integralnymi cz\u0119\u015bciami budynk\u00f3w komercyjnych. Przestrzenie te s\u0105 zazwyczaj wype\u0142nione p\u00f3\u0142kami, pud\u0142ami i r\u00f3\u017cnymi przedmiotami oraz s\u0142u\u017c\u0105 do przechowywania materia\u0142\u00f3w, sprz\u0119tu lub zarchiwizowanych dokument\u00f3w. O\u015bwietlenie w tych obszarach ma kluczowe znaczenie dla widoczno\u015bci i bezpiecze\u0144stwa, ale mo\u017ce te\u017c stanowi\u0107 istotne \u017ar\u00f3d\u0142o marnotrawstwa energii. Tradycyjne systemy o\u015bwietleniowe w pomieszczeniach magazynowych cz\u0119sto pozostaj\u0105 w\u0142\u0105czone niepotrzebnie, co prowadzi do wysokiego zu\u017cycia energii i koszt\u00f3w.<\/p>\n\n<p>Ponadto magazyny s\u0105 zwykle wyposa\u017cone w lampy fluorescencyjne lub LED, kt\u00f3re, cho\u0107 energooszcz\u0119dne, nadal mog\u0105 zu\u017cywa\u0107 znaczn\u0105 ilo\u015b\u0107 energii, gdy pozostaj\u0105 w\u0142\u0105czone przez d\u0142u\u017cszy czas. Sporadyczny i nieprzewidywalny charakter u\u017cytkowania magazyn\u00f3w dodatkowo pog\u0142\u0119bia ten problem, poniewa\u017c \u015bwiat\u0142a cz\u0119sto pozostaj\u0105 w\u0142\u0105czone nawet wtedy, gdy pomieszczenie jest nieu\u017cytkowane, co prowadzi do niepotrzebnych strat energii.<\/p>\n\n<p>To marnotrawstwo energii mo\u017cna ograniczy\u0107, stosuj\u0105c czujniki obecno\u015bci. Urz\u0105dzenia te automatycznie steruj\u0105 o\u015bwietleniem na podstawie obecno\u015bci lub braku os\u00f3b, zapewniaj\u0105c, \u017ce \u015bwiat\u0142a s\u0105 w\u0142\u0105czone tylko wtedy, gdy jest to potrzebne. Instaluj\u0105c czujniki obecno\u015bci w pomieszczeniach magazynowych, firmy mog\u0105 znacz\u0105co zmniejszy\u0107 zu\u017cycie energii, obni\u017cy\u0107 rachunki za media i przyczyni\u0107 si\u0119 do bardziej zr\u00f3wnowa\u017conego \u015brodowiska.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Poznaj kodeksy energetyczne<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>Mi\u0119dzynarodowy Kodeks Oszcz\u0119dzania Energii (IECC) to kodeks wzorcowy opracowany przez Mi\u0119dzynarodow\u0105 Rad\u0119 Kodeks\u00f3w (ICC) w celu ustanowienia minimalnych wymaga\u0144 projektowych i wykonawczych dotycz\u0105cych efektywno\u015bci energetycznej budynk\u00f3w. IECC jest aktualizowany co trzy lata, aby uwzgl\u0119dnia\u0107 najnowsze praktyki i technologie w zakresie oszcz\u0119dzania energii.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC \u2014 dlaczego powinno Ci\u0119 to interesowa\u0107<\/h3>\n\n<p>IECC jest powszechnie przyjmowany przez stany i gminy w ca\u0142ych Stanach Zjednoczonych. IECC obejmuje r\u00f3\u017cne aspekty zu\u017cycia energii, w tym przegrod\u0119 budynku (\u015bciany, dachy i okna), systemy ogrzewania i ch\u0142odzenia oraz systemy o\u015bwietleniowe.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>IECC nakazuje stosowanie okre\u015blonych element\u00f3w sterowania o\u015bwietleniem, takich jak czujniki obecno\u015bci, aby minimalizowa\u0107 marnotrawstwo energii w nieu\u017cytkowanych przestrzeniach w r\u00f3\u017cnych obszarach.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>ANSI\/ASHRAE\/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, to powszechnie uznawany standard energetyczny opublikowany przez American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1 \u2013 dlaczego powinno Ci\u0119 to obchodzi\u0107<\/h3>\n\n<p>ASHRAE 90.1 jest u\u017cywany jako punkt odniesienia dla kodeks\u00f3w energetycznych budynk\u00f3w w ca\u0142ych Stanach Zjednoczonych oraz stanowi \u015bcie\u017ck\u0119 zgodno\u015bci w ramach IECC, kt\u00f3ry okre\u015bla minimalne wymagania dotycz\u0105ce energooszcz\u0119dnej wydajno\u015bci element\u00f3w budynk\u00f3w komercyjnych, w tym przegr\u00f3d budowlanych, system\u00f3w HVAC, system\u00f3w podgrzewania wody oraz system\u00f3w o\u015bwietleniowych. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Norma ASHRAE 90.1 okre\u015bla maksymalne dopuszczalne g\u0119sto\u015bci mocy o\u015bwietleniowej oraz minimalne wymagania dotycz\u0105ce sterowania o\u015bwietleniem, w tym stosowanie czujnik\u00f3w obecno\u015bci w okre\u015blonych obszarach.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Title 24, cz\u0119\u015b\u0107 6 Kalifornijskiego Kodeksu Standard\u00f3w Budowlanych, oficjalnie znany jako Standardy Efektywno\u015bci Energetycznej Budynk\u00f3w dla Budynk\u00f3w Mieszkalnych i Niemieszkalnych (Building Energy Efficiency Standards for Residential and Nonresidential Buildings), jest administrowany przez Kalifornijsk\u0105 Komisj\u0119 Energetyczn\u0105 i jest okresowo aktualizowany, aby odzwierciedla\u0107 nowe technologie i metody poprawy efektywno\u015bci energetycznej.<\/p>\n\n<h3 class=\"wp-block-heading\">Title 24 \u2014 dlaczego powinno Ci\u0119 to obchodzi\u0107<\/h3>\n\n<p>Title 24 jest znany ze swoich rygorystycznych wymaga\u0144, cz\u0119sto uznawanych za bardziej restrykcyjne ni\u017c te wyst\u0119puj\u0105ce w wielu innych kodeksach energetycznych w Stanach Zjednoczonych. Title 24 nakazuje surowe standardy efektywno\u015bci energetycznej dla wszystkich aspekt\u00f3w budowy, w tym ogrzewania, wentylacji, klimatyzacji (HVAC), podgrzewania wody oraz o\u015bwietlenia.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Title 24 wymaga instalacji czujnik\u00f3w obecno\u015bci, kt\u00f3re dostosowuj\u0105 o\u015bwietlenie w zale\u017cno\u015bci od zaj\u0119to\u015bci pomieszczenia w okre\u015blonych obszarach budynk\u00f3w komercyjnych, aby energia nie by\u0142a marnowana.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Przyj\u0119cie kodeksu energetycznego wed\u0142ug stanu<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Rozwi\u0144, aby zobaczy\u0107 szczeg\u00f3\u0142ow\u0105 tabel\u0119 \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Stan<\/th><th>Obowi\u0105zuj\u0105cy kodeks komercyjny<\/th><th>Kategoria efektywno\u015bci komercyjnego kodeksu<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Brak w ca\u0142ym stanie<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Arizona<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>2009 IECC i 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kalifornia<\/td><td>Standardy efektywno\u015bci energetycznej budynk\u00f3w 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Kolorado<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Connecticut<\/td><td>2021 IECC i 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>2018 IECC i 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Dystrykt Kolumbii<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Floryda<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>2015 IECC i 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawaje<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>2018 IECC i 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>2021 IECC i 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>2012 IECC i 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Kentucky<\/td><td>2012 IECC i 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Luizjana<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>2015 IECC i 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>2018 IECC i 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>2015 IECC i 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Brak w ca\u0142ym stanie<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Missouri<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Montana<\/td><td>2021 IECC i 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>2018 IECC i 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>2018 IECC i 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>2018 IECC i 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nowy Meksyk<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nowy Jork<\/td><td>2018 IECC i 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Karolina P\u00f3\u0142nocna<\/td><td>2015 IECC i 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota P\u00f3\u0142nocna<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Ohio<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>2006 IECC i 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pensylwania<\/td><td>2018 IECC i 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>2018 IECC i 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Karolina Po\u0142udniowa<\/td><td>2009 IECC i 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota Po\u0142udniowa<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>Brak kodeksu stanowego<\/td><\/tr><tr><td>Tennessee<\/td><td>2021 IECC i 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Teksas<\/td><td>2015 IECC i 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Wirginia<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Waszyngton<\/td><td>2018 Kodeks Energetyczny stanu Waszyngton<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>2012 IECC i 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Teksas<\/td><td>2015 IECC i 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>2018 IECC i 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Wirginia<\/td><td>2021 IECC i 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Waszyngton<\/td><td>2018 Kodeks Energetyczny stanu Waszyngton<\/td><td>90.1-2019<\/td><\/tr><tr><td>Wirginia Zachodnia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>2015 IECC i 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Samorz\u0105dno\u015b\u0107 lokalna<\/td><td>Brak kodeksu stanowego<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Gdy poprawk\u0119 wp\u0142ywaj\u0105c\u0105 na efektywno\u015b\u0107 energetyczn\u0105 mo\u017cna by\u0142o ilo\u015bciowo oceni\u0107 za pomoc\u0105 modeli DOE Prototype Building Models, zosta\u0142a ona uj\u0119ta w analizie.<\/li>\n\n<li>W przypadku stan\u00f3w przyjmuj\u0105cych zar\u00f3wno IECC, jak i 90.1, w niniejszym opracowaniu kodeks IECC jest zwykle analizowany jako aktualnie obowi\u0105zuj\u0105cy kodeks stanowy, z wyj\u0105tkiem stan\u00f3w z rozleg\u0142ymi poprawkami do IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Rozwi\u0105zania czujnikowe<\/h4>\n\n<p>Dowiedz si\u0119, jak Rayzeek mo\u017ce rozwi\u0105za\u0107 Twoje wyzwania zwi\u0105zane z oszcz\u0119dzaniem energii.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/pl\/produkty\"><div class=\"offering_button\"><p>Zobacz ca\u0142\u0105 ofert\u0119<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-private-offices\">Kluczowe koncepcje przewodnika projektowego dla prywatnych biur<\/h2>\n\n<p>Projektowanie energooszcz\u0119dnego rozwi\u0105zania sterowania o\u015bwietleniem dla prywatnych biur obejmuje strategiczne rozmieszczenie czujnik\u00f3w obecno\u015bci, aby zapewni\u0107 kompleksowe pokrycie przestrzeni.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-18029\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>W magazynie podstawowymi obszarami wymagaj\u0105cymi o\u015bwietlenia s\u0105 g\u0142\u00f3wne ci\u0105gi komunikacyjne oraz poszczeg\u00f3lne alejki mi\u0119dzy rega\u0142ami. Oto kilka wskaz\u00f3wek, kt\u00f3rych warto przestrzega\u0107:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>G\u0142\u00f3wne ci\u0105gi komunikacyjne<\/strong>: Zainstaluj sufitowe czujniki obecno\u015bci w regularnych odst\u0119pach wzd\u0142u\u017c g\u0142\u00f3wnych ci\u0105g\u00f3w komunikacyjnych. Czujniki te powinny by\u0107 ustawione w trybie Auto ON i Full OFF, zapewniaj\u0105c automatyczne w\u0142\u0105czanie \u015bwiate\u0142, gdy kto\u015b wejdzie na ci\u0105g komunikacyjny, oraz wy\u0142\u0105czanie, gdy obszar jest pusty.<\/li>\n\n<li><strong>Poszczeg\u00f3lne alejki<\/strong>: W przypadku pojedynczych alejek mi\u0119dzy rega\u0142ami rozwa\u017c zainstalowanie na \u015bcianie czujnik\u00f3w obecno\u015bci przy wej\u015bciu do ka\u017cdej alejki. Czujniki te mog\u0105 wykrywa\u0107 wej\u015bcie osoby do alejki i odpowiednio w\u0142\u0105cza\u0107 o\u015bwietlenie. Ze wzgl\u0119du na sporadyczne korzystanie z tych alejek czujniki powinny by\u0107 ustawione w trybie Manual ON i Full OFF. Oznacza to, \u017ce \u015bwiat\u0142a w\u0142\u0105cz\u0105 si\u0119 tylko po r\u0119cznym w\u0142\u0105czeniu, ale wy\u0142\u0105cz\u0105 si\u0119 automatycznie, gdy alejka b\u0119dzie pusta.<\/li>\n\n<li><strong>Strefa wej\u015bciowa<\/strong>: W strefie wej\u015bciowej magazynu powinien znajdowa\u0107 si\u0119 \u015bcienny prze\u0142\u0105cznik z czujnikiem, umo\u017cliwiaj\u0105cy r\u0119czne sterowanie ca\u0142ym o\u015bwietleniem w pomieszczeniu. Prze\u0142\u0105cznika tego mo\u017cna u\u017cy\u0107 do w\u0142\u0105czania lub wy\u0142\u0105czania wszystkich \u015bwiate\u0142 w razie potrzeby, zapewniaj\u0105c dodatkowy poziom kontroli.<\/li>\n\n<li><strong>Uwagi dotycz\u0105ce rozmieszczenia czujnik\u00f3w<\/strong>: Podczas rozmieszczania czujnik\u00f3w upewnij si\u0119, \u017ce nie znajduj\u0105 si\u0119 one w pobli\u017cu kratek wentylacyjnych ani innych \u017ar\u00f3de\u0142 ruchu, kt\u00f3re mog\u0142yby powodowa\u0107 fa\u0142szywe zadzia\u0142ania. Upewnij si\u0119 r\u00f3wnie\u017c, \u017ce pole widzenia czujnik\u00f3w nie jest zas\u0142oni\u0119te przez rega\u0142y lub sk\u0142adowane przedmioty.<\/li>\n\n<li><strong>Wysoko\u015b\u0107 monta\u017cu czujnika<\/strong>: We\u017a pod uwag\u0119 wysoko\u015b\u0107 monta\u017cu czujnika. Czujniki nale\u017cy instalowa\u0107 na wysoko\u015bci zapewniaj\u0105cej optymalne pokrycie pomieszczenia, z uwzgl\u0119dnieniem wysoko\u015bci sk\u0142adowanych przedmiot\u00f3w.<\/li>\n\n<li><strong>Sterowanie r\u0119czne<\/strong>: Uwzgl\u0119dnij sterowanie r\u0119czne, aby umo\u017cliwi\u0107 u\u017cytkownikom w razie potrzeby w\u0142\u0105czanie\/wy\u0142\u0105czanie ca\u0142ego o\u015bwietlenia. Mo\u017ce to by\u0107 szczeg\u00f3lnie przydatne w magazynach, gdzie o\u015bwietlenie mo\u017ce by\u0107 wymagane przez d\u0142u\u017cszy czas podczas inwentaryzacji lub prac reorganizacyjnych.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Polecane produkty i rozwi\u0105zania<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pl\/kategoria-produktu\/czujniki-ruchu\/czujniki-ruchu-do-montazu-sciennego\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Na\u015bcienne prze\u0142\u0105czniki czujnikowe<\/h3>\n\n<h4 class=\"wp-block-heading\">Prze\u0142\u0105czniki czujnika ruchu RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Opcje okablowania 2-\u017cy\u0142owe, 3-\u017cy\u0142owe, 4-\u017cy\u0142owe <\/li>\n\n<li>Obecno\u015b\u0107, brak obecno\u015bci, r\u0119czne W\u0141.\/WY\u0141.<\/li>\n\n<li>Regulowane op\u00f3\u017anienie czasowe i sterowanie \u015bwiat\u0142em otoczenia<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/pl\/kategoria-produktu\/bezprzewodowe-czujniki-ruchu\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Bezprzewodowe czujniki \u015bcienne do wielu lokalizacji<\/h3>\n\n<h4 class=\"wp-block-heading\">Zestawy RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Przewodowy prze\u0142\u0105cznik czujnika obecno\u015bci RZ021A\/022A<\/li>\n\n<li>Bezprzewodowy prze\u0142\u0105cznik towarzysz\u0105cy (RZ022W) do sterowania z wielu lokalizacji<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/pl\/kategoria-produktu\/czujniki-obecnosci\/montaz-sufitowy\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sufitowe czujniki obecno\u015bci<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Przewodowe czujniki obecno\u015bci<\/li>\n\n<li>Auto ON, auto OFF <\/li>\n\n<li>Dost\u0119pne napi\u0119cie sieciowe i niskie napi\u0119cie<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Najwa\u017cniejsze funkcje w zestawie:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Zintegrowane r\u0119czne sterowanie W\u0141.\/WY\u0141. dla ca\u0142ego o\u015bwietlenia<\/li>\n\n<li>Czujniki nieobecno\u015bci (tylko r\u0119czne W\u0141.): \u015bwiat\u0142a musz\u0105 by\u0107 w\u0142\u0105czane wy\u0142\u0105cznie r\u0119cznie<\/li>\n\n<li>Regulowane op\u00f3\u017anienie czasowe, o\u015bwietlenie jest automatycznie ca\u0142kowicie wy\u0142\u0105czane po 15 min<\/li>\n\n<li>Dodatkowo: bezprzewodowe zestawy wielopunktowe do rozszerzenia zasi\u0119gu sterowania bez ponownego okablowania<\/li>\n\n<li>Dodatkowo: dost\u0119pne s\u0105 r\u00f3\u017cne opcje okablowania zar\u00f3wno dla nowych bud\u00f3w, jak i projekt\u00f3w modernizacyjnych.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18028\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Spe\u0142nia obowi\u0105zkowe wymagania<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Sterowanie czujnikami obecno\u015bci<\/h4>\n\n<p>W przestrzeni nale\u017cy zainstalowa\u0107 sterowanie czujnikami obecno\u015bci u\u017cytkownik\u00f3w, aby kontrolowa\u0107 o\u015bwietlenie.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Funkcje sterowania czujnika obecno\u015bci<\/h4>\n\n<ul class=\"wp-block-list\"><li>R\u0119czne w\u0142\u0105czenie lub cz\u0119\u015bciowe w\u0142\u0105czenie do nie wi\u0119cej ni\u017c 50% mocy.<\/li>\n\n<li>Ca\u0142kowite wy\u0142\u0105czenie w ci\u0105gu 20 minut po opuszczeniu przestrzeni przez wszystkich u\u017cytkownik\u00f3w<\/li>\n\n<li>R\u0119czne sterowanie do wy\u0142\u0105czania \u015bwiate\u0142.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Sterowanie lokalne<\/h4>\n\n<p>Musi istnie\u0107 jedno lub wi\u0119cej r\u0119cznych urz\u0105dze\u0144 sterowania o\u015bwietleniem zapewniaj\u0105cych sterowanie W\u0141. i WY\u0141.<br>ca\u0142ego o\u015bwietlenia w przestrzeni.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 H Automatyczne sterowanie pe\u0142nym wy\u0142\u0105czeniem <\/h4>\n\n<p>Ca\u0142e o\u015bwietlenie w tej przestrzeni musi zosta\u0107 automatycznie wy\u0142\u0105czone w ci\u0105gu 20 minut od momentu, gdy wszyscy u\u017cytkownicy opuszcz\u0105 przestrze\u0144<\/p>\n\n<p>Dodatkowo, dla magazyn\u00f3w o powierzchni &lt;50 ft2:<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Ograniczone do r\u0119cznego w\u0142\u0105czania<\/h4>\n\n<p>\u017badne z o\u015bwietlenia nie mo\u017ce by\u0107 automatycznie w\u0142\u0105czane<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Title 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) R\u0119czne sterowanie strefowe.<\/h4>\n\n<p>Ka\u017cdy obszar wydzielony przegrodami o wysoko\u015bci do sufitu musi zapewnia\u0107 sterowanie o\u015bwietleniem, kt\u00f3re umo\u017cliwia r\u0119czne w\u0142\u0105czanie i wy\u0142\u0105czanie o\u015bwietlenia w tym obszarze.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Sterowanie wy\u0142\u0105czeniem.<\/h4>\n\n<p>O\u015bwietlenie powinno by\u0107 sterowane czujnikami wykrywaj\u0105cymi obecno\u015b\u0107 u\u017cytkownik\u00f3w, aby automatycznie WY\u0141\u0104CZA\u0106 ca\u0142e o\u015bwietlenie w ci\u0105gu 20 minut lub kr\u00f3cej po tym, jak strefa sterowania jest nieu\u017cytkowana, i dzia\u0142a\u0107 w jeden z nast\u0119puj\u0105cych sposob\u00f3w:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Sterowanie czujnikiem obecno\u015bci (je\u015bli 130.1(b) nie wymaga wielopoziomowego sterowania o\u015bwietleniem); lub<\/li>\n\n<li>B. Sterowanie czujnikiem obecno\u015bci z cz\u0119\u015bciowym w\u0142\u0105czaniem, lub<\/li>\n\n<li>C. Sterowanie czujnikiem braku obecno\u015bci, gdzie ca\u0142e o\u015bwietlenie reaguje wy\u0142\u0105cznie na r\u0119czne polecenie ON<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Chcemy Ci\u0119 us\u0142ysze\u0107.<\/h3>\n\n<p>Pozw\u00f3l Rayzeek zaprojektowa\u0107 i dostarczy\u0107 dla Ciebie spersonalizowane, energooszcz\u0119dne rozwi\u0105zanie o\u015bwietleniowe.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pl\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Formularz kontaktowy\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/pl\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Prze\u015blij\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"pl\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Pomieszczenia magazynowe, cz\u0119sto pomijane, s\u0105 integralnymi cz\u0119\u015bciami budynk\u00f3w komercyjnych. Przestrzenie te s\u0105 zazwyczaj wype\u0142nione p\u00f3\u0142kami, pud\u0142ami i r\u00f3\u017cnymi przedmiotami oraz s\u0142u\u017c\u0105 do przechowywania materia\u0142\u00f3w, sprz\u0119tu lub zarchiwizowanych dokument\u00f3w.<\/p>","protected":false},"author":1,"featured_media":18031,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18027","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Storage Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/pl\/przewodnik-projektowania-przechowalni\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Storage Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/pl\/przewodnik-projektowania-przechowalni\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide\",\"name\":\"Storage Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T09:12:15+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/storage-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Storage Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Storage Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/pl\/przewodnik-projektowania-przechowalni","og_locale":"pl_PL","og_type":"article","og_title":"Storage Room Energy Code Design Guide - Rayzeek","og_description":"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.","og_url":"https:\/\/www.rayzeek.com\/pl\/przewodnik-projektowania-przechowalni","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Szacowany czas czytania":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide","url":"https:\/\/www.rayzeek.com\/storage-room-design-guide","name":"Storage Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","datePublished":"2024-05-21T09:12:15+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/storage-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Storage Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/pages\/18027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/comments?post=18027"}],"version-history":[{"count":4,"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/pages\/18027\/revisions"}],"predecessor-version":[{"id":18153,"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/pages\/18027\/revisions\/18153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/media\/18031"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/pl\/wp-json\/wp\/v2\/media?parent=18027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}