RZ047-5A 360-Degree Ceiling Microwave Motion Sensor Switch

RZ047-5A

RZ047-5A is a 100-265 VAC ceiling-mounted microwave motion sensor switch for automatic indoor lighting control.

The 5A model uses high-frequency microwave Doppler sensing, neutral-required AC wiring, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted lighting control.

  • 100-265 VAC line-voltage input, 5A model
  • 5.8 GHz microwave sensing with 360-degree coverage
  • 8-12 m detection diameter under manual conditions
  • Time delay: 15 s to 30 min
  • Lux setting: Off, 15, 25, or 35 Lux
자세히 보기

제품 주요 내용

  • 5A AC model: 100-265 VAC ceiling microwave sensor switch for verified RZ047-5A load ratings.
  • Microwave sensing: 5.8 GHz Doppler detection with 360-degree ceiling coverage.
  • Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.

빠른 배송: 99% 재고 있음

풀 모션 인식 제품 라인

문의 대량 ODM/OEM 주문의 경우

RZ047-5A ceiling microwave motion sensor switch product image

5A Ceiling Microwave Sensing For Automatic Lighting

The RZ047-5A is a ceiling-mounted microwave motion sensor switch for indoor automatic lighting control where overhead sensing is preferred over a wall switch.

It uses 100-265 VAC live, neutral, and load wiring, with push-button adjustment for time delay, Lux threshold, and high/low sensitivity after installation.

Indoor utility room with ceiling lighting for RZ047-5A microwave sensing context

360-Degree Microwave Coverage For Everyday Rooms

Microwave Doppler sensing can detect movement through many non-metal materials such as glass, plastic, and thin partitions, which helps ceiling placement cover practical indoor room layouts.

Because that same sensitivity can also detect movement outside the intended area, installers should reduce sensitivity or relocate the sensor when doors, windows, partitions, metal surfaces, or moving fixtures cause nuisance triggering.

기능, 장점, 사양

The RZ047-5A combines 5A AC lighting control, 5.8 GHz microwave detection, and adjustable ceiling-sensor settings so installers can verify load fit, placement, and setup before ordering.

RZ047 time delay Lux sensitivity adjustment buttons

기능 및 이점

  • 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ047-5A load ratings shown in the specifications.
  • 5.8 GHz microwave sensing: High-frequency Doppler detection actively senses movement for ceiling-mounted automatic lighting control.
  • 360-degree ceiling coverage: Ceiling placement gives broad room coverage with an 8-12 m detection diameter under manual conditions.
  • Non-metal material penetration: Microwave detection can pass through many plastics, glass, and thin partitions, while metal blocks detection.
  • Adjustable time delay: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match room traffic patterns.
  • Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux so the load responds to motion only when the ambient-light condition fits the installation.
  • High/low sensitivity: The SENS button helps reduce nuisance detection through doors, glass, partitions, or adjacent spaces.
특징

Model

RZ047-5A

Product type

Ceiling-mounted microwave motion sensor switch

Sensor type

High-frequency microwave Doppler (HF)

Microwave frequency

5.8 GHz ISM band

Transmission power

0.4 mW

시간 지연

15초, 30초, 1분(기본값), 3분, 5분, 10분, 30분

Light sensor level

끄기, 15룩스, 25룩스(기본값), 35룩스

감도

High or Low

Material penetration

Detects through most plastics, glass, and thin partitions; metal blocks detection

Electrical

전원 소스

100 진공 ~ 265 진공

Power frequency

50/60 Hz

배선

White to Neutral; Red to Load; Black to Live

전력 소비

<=0.5 W standby; 1 W operation

Incandescent / Halogen load

500 W / 110 VAC; 1100 W / 220 VAC

Fluorescent / Ballast / LED load

250 W / 110 VAC; 500 W / 220 VAC

Detection & Installation

Detection diameter

8-12 m

Detection range

360-degree ceiling coverage

Installation height

2.5-5 m

Working temperature

-10 to +40 C

Working humidity

< 93% RH non-condensing

Metal clearance

Keep at least 1 m from large metal or highly reflective surfaces; do not fully enclose in metal

Installation notes

Avoid windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, and vibrating fixtures that may cause nuisance detection

자주 묻는 질문

How is the RZ047-5A different from a PIR ceiling sensor?

RZ047 uses high-frequency microwave Doppler sensing. It can detect through many non-metal materials such as glass, plastic, and thin partitions, while metal blocks detection.

Does the RZ047-5A need a neutral wire?

Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.

What loads can the 5A model control?

The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.

Can microwave sensing trigger from outside the room?

Yes. The manual warns that microwave sensing can detect through glass, doors, or partitions, so sensitivity should be reduced or the sensor relocated if nuisance detection occurs.

What settings can installers adjust?

Installers can adjust time delay, Lux threshold, and high/low sensitivity using the buttons under the top cover.

Where should the RZ047 be installed?

The manual lists a 2.5-5 m installation height and recommends avoiding windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, vibrating fixtures, and large metal surfaces.

EU rz022 재실 센서 c2a