{"id":18003,"date":"2024-05-21T08:47:21","date_gmt":"2024-05-21T08:47:21","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=18003"},"modified":"2024-06-05T02:22:40","modified_gmt":"2024-06-05T02:22:40","slug":"lobby-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/it\/guida-alla-progettazione-dellatrio","title":{"rendered":"Guida alla progettazione della hall"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18009\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"lobby\">Atrio<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Scopri il potenziale di risparmio energetico del tuo atrio. Impara come rispettare i codici energetici e ridurre gli sprechi di energia con le nostre soluzioni su misura.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1.jpg\" alt=\"\" class=\"wp-image-18004\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-1-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"transform-your-lobby-into-an-energyefficient-space\">Trasforma il tuo atrio in uno spazio ad alta efficienza energetica<\/h2>\n\n<p>L\u2019atrio \u00e8 spesso il primo punto di contatto per visitatori e dipendenti in un edificio commerciale. \u00c8 uno spazio che deve essere ben illuminato e accogliente in ogni momento. \u00c8 un\u2019area vivace, piena di persone che vanno e vengono a tutte le ore. L\u2019illuminazione in queste aree \u00e8 in genere ad alta intensit\u00e0 e rimane accesa per lunghi periodi, con conseguente consumo energetico significativo.<\/p>\n\n<p>I sistemi di illuminazione tradizionali negli atri sono spesso controllati manualmente, con il risultato che le luci vengono lasciate accese inutilmente quando lo spazio non \u00e8 occupato, causando un elevato spreco di energia. Inoltre, le diverse attivit\u00e0 e i livelli di occupazione variabili negli atri rendono difficile gestire l\u2019illuminazione in modo efficiente. Ci\u00f2 non solo aumenta i costi operativi, ma contribuisce anche a una maggiore impronta di carbonio.<\/p>\n\n<p>Per affrontare questi problemi, i sensori di presenza offrono una soluzione efficace. Questi dispositivi possono spegnere automaticamente o attenuare le luci quando l\u2019atrio \u00e8 vuoto, riducendo significativamente il consumo energetico. La gamma di sensori di presenza Rayzeek, inclusi modelli a parete e a soffitto, offre una soluzione su misura per gli atri, garantendo un controllo efficiente dell\u2019illuminazione senza compromettere comfort o sicurezza.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Conosci i codici energetici<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>L'International Energy Conservation Code (IECC) \u00e8 un codice modello sviluppato dall'International Code Council (ICC) per stabilire requisiti minimi di progettazione e costruzione per l'efficienza energetica negli edifici. L'IECC viene aggiornato ogni tre anni per incorporare le pi\u00f9 recenti pratiche e tecnologie di conservazione dell'energia.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, perch\u00e9 dovrebbe interessarti<\/h3>\n\n<p>L\u2019IECC \u00e8 ampiamente adottato da stati e municipalit\u00e0 in tutti gli Stati Uniti. L\u2019IECC copre vari aspetti dell\u2019uso dell\u2019energia, tra cui l\u2019involucro dell\u2019edificio (pareti, tetti e finestre), gli impianti di riscaldamento e raffrescamento e i sistemi di illuminazione.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>L\u2019IECC impone controlli specifici per l\u2019illuminazione, come i sensori di presenza, per ridurre al minimo lo spreco di energia negli spazi non occupati in varie aree.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>La norma ANSI\/ASHRAE\/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, \u00e8 uno standard energetico ampiamente riconosciuto pubblicato dall\u2019American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1: perch\u00e9 dovrebbe interessarti<\/h3>\n\n<p>ASHRAE 90.1 \u00e8 utilizzato come riferimento per i codici energetici degli edifici in tutti gli Stati Uniti e funge da percorso di conformit\u00e0 all\u2019interno dell\u2019IECC, che definisce i requisiti minimi per le prestazioni energeticamente efficienti dei componenti degli edifici commerciali, inclusi involucri edilizi, sistemi HVAC, sistemi di riscaldamento dell\u2019acqua e sistemi di illuminazione. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>La norma ASHRAE 90.1 specifica le densit\u00e0 massime consentite di potenza di illuminazione e i requisiti minimi di controllo dell\u2019illuminazione, incluso l\u2019uso di sensori di presenza in aree specifiche.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Il Titolo 24, parte 6 del California Building Standards Code, ufficialmente noto come Building Energy Efficiency Standards for Residential and Nonresidential Buildings, \u00e8 amministrato dalla California Energy Commission e viene aggiornato periodicamente per riflettere nuove tecnologie e metodi di efficienza energetica.<\/p>\n\n<h3 class=\"wp-block-heading\">Titolo 24: perch\u00e9 dovrebbe interessarti<\/h3>\n\n<p>Il Titolo 24 \u00e8 noto per i suoi requisiti rigorosi, spesso considerati pi\u00f9 severi di quelli presenti in molti altri codici energetici negli Stati Uniti. Il Titolo 24 impone standard rigorosi di prestazione energetica per tutti gli aspetti della costruzione degli edifici, inclusi riscaldamento, ventilazione, condizionamento dell'aria (HVAC), riscaldamento dell'acqua e illuminazione.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Il Titolo 24 richiede l'installazione di sensori di presenza che regolano l'illuminazione in base all'occupazione della stanza in aree specifiche degli edifici commerciali, per garantire che l'energia non venga sprecata.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Adozione del codice energetico per stato<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Espandi per vedere la tabella dettagliata \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Stato<\/th><th>Codice commerciale attuale<\/th><th>Categoria di efficienza del codice commerciale<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Nessuno a livello statale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Arizona<\/td><td>Autonomia locale<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>California<\/td><td>Standard di Efficienza Energetica degli Edifici 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonomia locale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distretto di Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Florida<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawaii<\/td><td>Autonomia locale<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonomia locale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiana<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Nessuno a livello statale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Missouri<\/td><td>Autonomia locale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 e 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>New Mexico<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>North Carolina<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>North Dakota<\/td><td>Autonomia locale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 e 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvania<\/td><td>IECC 2018 e 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>South Carolina<\/td><td>IECC 2009 e 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>South Dakota<\/td><td>Autonomia locale<\/td><td>Nessun codice a livello statale<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 e 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Codice Energetico dello Stato di Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 e 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 e 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 e 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>IECC 2021 e 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Codice Energetico dello Stato di Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>West Virginia<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 e 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonomia locale<\/td><td>Nessun codice a livello statale<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Quando un emendamento che incide sull\u2019efficienza energetica pu\u00f2 essere quantificato utilizzando i DOE Prototype Building Models, \u00e8 stato incluso nell\u2019analisi.<\/li>\n\n<li>Per gli stati che adottano sia l\u2019IECC sia la 90.1, in questo studio il codice IECC viene generalmente analizzato come codice statale vigente, fatta eccezione per gli stati con ampie modifiche all\u2019IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Soluzioni con sensori<\/h4>\n\n<p>Scopri come Rayzeek pu\u00f2 risolvere le tue sfide di risparmio energetico.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/it\/prodotti\"><div class=\"offering_button\"><p>Visualizza tutte le offerte<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-lobby\">Concetti chiave della guida di progettazione per l\u2019atrio<\/h2>\n\n<p>Progettare una soluzione di controllo dell\u2019illuminazione ad alta efficienza energetica per un atrio comporta il posizionamento strategico di sensori di presenza per garantire una copertura completa dello spazio.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4.jpg\" alt=\"\" class=\"wp-image-18007\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>In un atrio, le principali aree che devono essere coperte dai sensori di presenza sono l\u2019ingresso, il banco reception e qualsiasi area con sedute o di attesa. Ecco una possibile guida di progettazione per un atrio:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Area d\u2019ingresso<\/strong>: Installa un sensore di presenza a soffitto vicino all\u2019ingresso. Questo sensore rilever\u00e0 il movimento delle persone che entrano o escono dall\u2019atrio, garantendo l\u2019attivazione delle luci quando necessario. I nostri sensori a soffitto offrono la funzionalit\u00e0 Auto ON e Full OFF, fornendo un controllo automatico dell\u2019illuminazione in base all\u2019occupazione.<\/li>\n\n<li><strong>Area principale dell\u2019atrio<\/strong>: Per atri pi\u00f9 grandi, potrebbero essere necessari sensori aggiuntivi a soffitto per coprire l\u2019intero spazio. Questi sensori dovrebbero essere posizionati strategicamente per coprire le aree ad alto traffico, ad esempio vicino al banco reception o alle aree di attesa. La copertura sovrapposta di pi\u00f9 sensori garantisce che non ci siano punti ciechi.<\/li>\n\n<li><strong>Banco reception<\/strong>: Posiziona un sensore montato a parete vicino al banco reception. Questo sensore rilever\u00e0 la presenza del receptionist e di eventuali visitatori al banco, mantenendo le luci accese in quest\u2019area durante i periodi di occupazione.<\/li>\n\n<li><strong>Aree con sedute\/di attesa<\/strong>: Installa sensori aggiuntivi montati a soffitto in eventuali aree con sedute o di attesa. Questi sensori rileveranno quando tali aree sono occupate e regoleranno l\u2019illuminazione di conseguenza.<\/li>\n\n<li><strong>Controllo manuale<\/strong>: Installa un comando manuale vicino all\u2019ingresso o al banco reception. Questo consente di intervenire manualmente sul sistema di illuminazione quando necessario.<\/li>\n\n<li><strong>Corridoi che conducono ad altre aree<\/strong>: I corridoi che conducono agli ascensori, alle scale o ad altre parti dell\u2019edificio dovrebbero avere propri sensori montati a parete o a soffitto. Ci\u00f2 garantisce che le luci in queste aree si attivino solo quando qualcuno vi transita.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Prodotti e soluzioni in evidenza<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/it\/categoria-di-prodotto\/sensori-di-movimento\/sensori-di-movimento-a-montaggio-a-parete\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruttori con sensore da parete<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruttori con sensore di movimento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Opzioni di cablaggio a 2 fili, 3 fili, 4 fili <\/li>\n\n<li>Presenza, assenza, ON\/OFF manuale<\/li>\n\n<li>Ritardo temporale regolabile e controllo della luce ambientale<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/it\/categoria-di-prodotto\/sensori-di-movimento-wireless\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensori da parete wireless multi-posizione<\/h3>\n\n<h4 class=\"wp-block-heading\">Kit RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruttore con sensore di presenza cablato RZ021A\/022A<\/li>\n\n<li>Interruttore ausiliario wireless (RZ022W) per il controllo da pi\u00f9 punti<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/it\/categoria-di-prodotto\/sensori-di-occupazione\/montaggio-a-soffitto\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensori di presenza a soffitto<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensori di presenza cablati<\/li>\n\n<li>Accensione automatica, spegnimento automatico <\/li>\n\n<li>Disponibili tensione di linea e bassa tensione<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Caratteristiche principali incluse:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Controllo manuale ON\/OFF integrato per tutta l\u2019illuminazione<\/li>\n\n<li>Sensori di assenza (solo ACCENSIONE manuale): le luci devono essere accese solo manualmente<\/li>\n\n<li>Ritardo temporale regolabile, l\u2019illuminazione viene automaticamente spenta completamente dopo 15 minuti<\/li>\n\n<li>Aggiuntivo: kit wireless multi-postazione per estendere la portata del controllo senza ricablaggio<\/li>\n\n<li>Aggiuntivo: sono disponibili diverse opzioni di cablaggio sia per nuove costruzioni sia per progetti di retrofit.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18005\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Soddisfa le disposizioni obbligatorie<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controlli del sensore di presenza<\/h4>\n\n<p>Devono essere installati controlli con sensore di presenza per controllare le luci nello spazio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Funzioni di controllo del sensore di presenza<\/h4>\n\n<ul class=\"wp-block-list\"><li>Accensione manuale o accensione parziale fino a non pi\u00f9 del 50% della potenza.<\/li>\n\n<li>Spegnimento totale entro 20 minuti dopo che tutti gli occupanti hanno lasciato lo spazio<\/li>\n\n<li>Un comando manuale per spegnere le luci.<\/li><\/ul>\n\n<p>I controlli completamente automatici (accensione automatica) senza comando manuale sono consentiti negli atri in cui l\u2019azionamento manuale metterebbe in pericolo la sicurezza o la protezione degli occupanti.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Controllo locale<\/h4>\n\n<p>Devono essere presenti uno o pi\u00f9 dispositivi di controllo manuale dell'illuminazione che forniscano il controllo di ACCENSIONE e SPEGNIMENTO<br>di tutta l\u2019illuminazione nello spazio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-g-automatic-reduction-control\">9.4.1.1 g Controllo di riduzione automatica<\/h4>\n\n<p>La potenza dell\u2019illuminazione generale nello spazio deve essere ridotta automaticamente di almeno 50% entro 15 minuti dall\u2019uscita di tutti gli occupanti dallo spazio.<\/p>\n\n<p>** NOTA:  9.4.1.1 g \u00e8 richiesto in tutti gli altri atri, ad eccezione di (Ascensore, Hotel, Cinema, Teatro di arti performative\uff09<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Controllo di spegnimento automatico completo<\/h4>\n\n<p>Tutta l\u2019illuminazione nello spazio deve essere automaticamente spenta entro 15 minuti dall\u2019uscita di tutti gli occupanti dallo spazio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-i-scheduled-shutoff\">9.4.1.1 i Spegnimento programmato<\/h4>\n\n<p>Tutta l\u2019illuminazione nello spazio deve essere automaticamente spenta durante i periodi in cui lo spazio \u00e8 programmato come non occupato.<\/p>\n\n<p>** NOTA: Deve essere implementato almeno uno tra 9.4.1.1 h o 9.4.1.1 i.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Titolo 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controlli manuali dell\u2019area.<\/h4>\n\n<p>Ogni area delimitata da pareti divisorie a tutta altezza deve prevedere controlli dell\u2019illuminazione che consentano di accendere e spegnere manualmente l\u2019illuminazione in quell\u2019area.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controlli di spegnimento.<\/h4>\n\n<p>L\u2019illuminazione deve essere controllata tramite controlli con rilevamento dell\u2019occupante, per spegnere automaticamente tutta l\u2019illuminazione entro 20 minuti o meno dopo che la zona di controllo risulta non occupata, e deve funzionare come:<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Controlli a rilevamento di presenza (se 130.1(b) non richiede controlli di illuminazione multilivello); oppure<\/li>\n\n<li>B. Controlli a rilevamento di presenza con accensione parziale, oppure<\/li>\n\n<li>C. Controlli a rilevamento di assenza, in cui tutta l\u2019illuminazione risponde solo a un input di accensione manuale<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Facci sapere.<\/h3>\n\n<p>Lascia che Rayzeek ti aiuti a progettare e fornire una soluzione di illuminazione su misura per il risparmio energetico.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/it\/wp-json\/wp\/v2\/pages\/18003#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Modulo di contatto\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/it\/wp-json\/wp\/v2\/pages\/18003#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Invia\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"it\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>L'atrio \u00e8 spesso il primo punto di contatto per i visitatori e i dipendenti di un edificio commerciale. \u00c8 uno spazio che deve essere sempre ben illuminato e accogliente.<\/p>","protected":false},"author":1,"featured_media":18009,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18003","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Lobby Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/it\/guida-alla-progettazione-dellatrio\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lobby Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"The lobby is often the first point of contact for visitors and employees in a commercial building. It&#8217;s a space that needs to be well-lit and welcoming at all times.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/it\/guida-alla-progettazione-dellatrio\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/lobby-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/lobby-design-guide\",\"name\":\"Lobby Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/lobby-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/lobby-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:47:21+00:00\",\"dateModified\":\"2024-06-05T02:22:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/lobby-design-guide#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/lobby-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.rayzeek.com\/lobby-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/lobby-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lobby Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lobby Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/it\/guida-alla-progettazione-dellatrio","og_locale":"it_IT","og_type":"article","og_title":"Lobby Energy Code Design Guide - Rayzeek","og_description":"The lobby is often the first point of contact for visitors and employees in a commercial building. It&#8217;s a space that needs to be well-lit and welcoming at all times.","og_url":"https:\/\/www.rayzeek.com\/it\/guida-alla-progettazione-dellatrio","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:40+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tempo di lettura stimato":"4 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/lobby-design-guide","url":"https:\/\/www.rayzeek.com\/lobby-design-guide","name":"Lobby Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/lobby-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/lobby-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg","datePublished":"2024-05-21T08:47:21+00:00","dateModified":"2024-06-05T02:22:40+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/lobby-design-guide#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/lobby-design-guide"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.rayzeek.com\/lobby-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/lobby-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/lobby-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Lobby Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/pages\/18003","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/comments?post=18003"}],"version-history":[{"count":9,"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/pages\/18003\/revisions"}],"predecessor-version":[{"id":18157,"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/pages\/18003\/revisions\/18157"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/media\/18009"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/it\/wp-json\/wp\/v2\/media?parent=18003"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}