{"id":18027,"date":"2024-05-21T09:12:15","date_gmt":"2024-05-21T09:12:15","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=18027"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"storage-room-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-locaux-de-stockage","title":{"rendered":"Guide de conception pour salle de stockage"},"content":{"rendered":"<div class=\"wp-block-cover alignfull rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-18031\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"storage-rooms\">locaux de stockage<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">D\u00e9couvrez le potentiel d\u2019\u00e9conomies d\u2019\u00e9nergie des locaux de stockage gr\u00e2ce au guide de conception de capteurs de pr\u00e9sence de Rayzeek.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg\" alt=\"\" class=\"wp-image-18030\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-5-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-storage-rooms-with-occupancy-sensors\">Maximisez l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique dans les locaux de stockage avec des capteurs de pr\u00e9sence<\/h2>\n\n<p>Les locaux de stockage, souvent n\u00e9glig\u00e9s, sont des \u00e9l\u00e9ments essentiels des b\u00e2timents commerciaux. Ces espaces sont g\u00e9n\u00e9ralement remplis d\u2019\u00e9tag\u00e8res, de cartons et de divers objets, et servent \u00e0 stocker des fournitures, du mat\u00e9riel ou des documents archiv\u00e9s. L\u2019\u00e9clairage dans ces zones est crucial pour la visibilit\u00e9 et la s\u00e9curit\u00e9, mais il peut aussi \u00eatre une source importante de gaspillage d\u2019\u00e9nergie. Les syst\u00e8mes d\u2019\u00e9clairage traditionnels dans les locaux de stockage sont souvent laiss\u00e9s allum\u00e9s inutilement, entra\u00eenant une consommation d\u2019\u00e9nergie et des co\u00fbts \u00e9lev\u00e9s.<\/p>\n\n<p>De plus, les locaux de stockage sont g\u00e9n\u00e9ralement \u00e9quip\u00e9s de lampes fluorescentes ou LED qui, bien qu\u2019\u00e9conomes en \u00e9nergie, peuvent tout de m\u00eame consommer une quantit\u00e9 consid\u00e9rable d\u2019\u00e9lectricit\u00e9 lorsqu\u2019elles restent allum\u00e9es pendant de longues p\u00e9riodes. Le caract\u00e8re sporadique et impr\u00e9visible de l\u2019utilisation des locaux de stockage aggrave encore ce probl\u00e8me, car les lumi\u00e8res sont souvent laiss\u00e9es allum\u00e9es m\u00eame lorsque la pi\u00e8ce est inoccup\u00e9e, entra\u00eenant un gaspillage d\u2019\u00e9nergie inutile.<\/p>\n\n<p>Ce gaspillage d\u2019\u00e9nergie peut \u00eatre att\u00e9nu\u00e9 gr\u00e2ce \u00e0 l\u2019utilisation de d\u00e9tecteurs de pr\u00e9sence. Ces dispositifs commandent automatiquement l\u2019\u00e9clairage en fonction de la pr\u00e9sence ou de l\u2019absence de personnes, garantissant que les lumi\u00e8res ne sont allum\u00e9es qu\u2019en cas de besoin. En installant des d\u00e9tecteurs de pr\u00e9sence dans les locaux de stockage, les entreprises peuvent r\u00e9duire significativement leur consommation d\u2019\u00e9nergie, diminuer leurs factures d\u2019\u00e9lectricit\u00e9 et contribuer \u00e0 un environnement plus durable.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Respecter les codes \u00e9nerg\u00e9tiques<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>Le Code international de conservation de l\u2019\u00e9nergie (IECC) est un code mod\u00e8le \u00e9labor\u00e9 par l\u2019International Code Council (ICC) afin d\u2019\u00e9tablir des exigences minimales de conception et de construction en mati\u00e8re d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents. L\u2019IECC est mis \u00e0 jour tous les trois ans afin d\u2019int\u00e9grer les derni\u00e8res pratiques et technologies en mati\u00e8re de conservation de l\u2019\u00e9nergie.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, pourquoi vous devriez vous en soucier<\/h3>\n\n<p>L\u2019IECC est largement adopt\u00e9 par les \u00c9tats et les municipalit\u00e9s \u00e0 travers les \u00c9tats-Unis. L\u2019IECC couvre divers aspects de la consommation d\u2019\u00e9nergie, notamment l\u2019enveloppe du b\u00e2timent (murs, toitures et fen\u00eatres), les syst\u00e8mes de chauffage et de refroidissement, ainsi que les syst\u00e8mes d\u2019\u00e9clairage.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>L\u2019IECC impose des commandes d\u2019\u00e9clairage sp\u00e9cifiques, telles que des d\u00e9tecteurs de pr\u00e9sence, afin de minimiser le gaspillage d\u2019\u00e9nergie dans les espaces inoccup\u00e9s dans diverses zones.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>La norme ANSI\/ASHRAE\/IES 90.1, Norme \u00e9nerg\u00e9tique pour les sites et les b\u00e2timents \u00e0 l\u2019exception des b\u00e2timents r\u00e9sidentiels de faible hauteur, est une norme \u00e9nerg\u00e9tique largement reconnue publi\u00e9e par l\u2019American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1 : pourquoi vous devriez vous en soucier<\/h3>\n\n<p>L\u2019ASHRAE 90.1 est utilis\u00e9e comme r\u00e9f\u00e9rence pour les codes \u00e9nerg\u00e9tiques du b\u00e2timent \u00e0 travers les \u00c9tats-Unis et sert de voie de conformit\u00e9 dans l\u2019IECC, qui d\u00e9finit des exigences minimales de performance \u00e9co\u00e9nerg\u00e9tique des composants des b\u00e2timents commerciaux, notamment les enveloppes du b\u00e2timent, les syst\u00e8mes CVC, les syst\u00e8mes de chauffage de l\u2019eau et les syst\u00e8mes d\u2019\u00e9clairage. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>La norme ASHRAE 90.1 sp\u00e9cifie les densit\u00e9s de puissance d\u2019\u00e9clairage maximales autoris\u00e9es et les exigences minimales en mati\u00e8re de commande d\u2019\u00e9clairage, y compris l\u2019utilisation de capteurs de pr\u00e9sence dans des zones sp\u00e9cifiques.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Le Titre 24, partie 6 du California Building Standards Code, officiellement appel\u00e9 \u00ab Building Energy Efficiency Standards for Residential and Nonresidential Buildings \u00bb, est administr\u00e9 par la California Energy Commission et est mis \u00e0 jour p\u00e9riodiquement afin de refl\u00e9ter les nouvelles technologies et m\u00e9thodes d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique.<\/p>\n\n<h3 class=\"wp-block-heading\">Titre 24, pourquoi vous devriez vous en soucier<\/h3>\n\n<p>Le Titre 24 est connu pour ses exigences rigoureuses, souvent consid\u00e9r\u00e9es comme plus strictes que celles de nombreux autres codes \u00e9nerg\u00e9tiques aux \u00c9tats-Unis. Le Titre 24 impose des normes strictes de performance \u00e9nerg\u00e9tique pour tous les aspects de la construction des b\u00e2timents, notamment le chauffage, la ventilation, la climatisation (CVC), le chauffage de l\u2019eau et l\u2019\u00e9clairage.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Le Titre 24 exige l\u2019installation de capteurs d\u2019occupation qui ajustent l\u2019\u00e9clairage en fonction de l\u2019occupation des pi\u00e8ces dans certaines zones des b\u00e2timents commerciaux afin d\u2019\u00e9viter tout gaspillage d\u2019\u00e9nergie.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Adoption des codes \u00e9nerg\u00e9tiques par \u00c9tat<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">D\u00e9veloppez pour voir le tableau d\u00e9taill\u00e9 \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u00c9tat<\/th><th>Code commercial en vigueur<\/th><th>Cat\u00e9gorie d\u2019efficacit\u00e9 du code commercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Aucun \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Arizona<\/td><td>Autonomie locale<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 et 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Californie<\/td><td>Normes d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 et 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>District de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Floride<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>G\u00e9orgie<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawa\u00ef<\/td><td>Autonomie locale<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 et 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 et 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 et 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiane<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 et 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Aucun \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Missouri<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 et 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nouveau-Mexique<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Caroline du Nord<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota du Nord<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 et 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvanie<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Caroline du Sud<\/td><td>IECC 2009 et 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota du Sud<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 et 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 et 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginie<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Code de l\u2019\u00e9nergie de l\u2019\u00c9tat de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 et 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 et 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginie<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Code de l\u2019\u00e9nergie de l\u2019\u00c9tat de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginie-Occidentale<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Lorsqu\u2019un amendement ayant un impact sur l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique peut \u00eatre quantifi\u00e9 \u00e0 l\u2019aide des mod\u00e8les de b\u00e2timents prototypes du DOE, il a \u00e9t\u00e9 pris en compte dans l\u2019analyse.<\/li>\n\n<li>Pour les \u00c9tats adoptant \u00e0 la fois l\u2019IECC et la norme 90.1, le code IECC est g\u00e9n\u00e9ralement analys\u00e9 comme le code en vigueur de l\u2019\u00c9tat dans cette \u00e9tude, sauf pour les \u00c9tats ayant des amendements importants \u00e0 l\u2019IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solutions de capteurs<\/h4>\n\n<p>D\u00e9couvrez comment Rayzeek peut r\u00e9soudre vos d\u00e9fis en mati\u00e8re d\u2019\u00e9conomies d\u2019\u00e9nergie.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/fr\/produits\"><div class=\"offering_button\"><p>Voir toutes les offres<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-private-offices\">Concepts cl\u00e9s du guide de conception pour les bureaux priv\u00e9s<\/h2>\n\n<p>La conception d\u2019une solution de commande d\u2019\u00e9clairage \u00e9co\u00e9nerg\u00e9tique pour des bureaux priv\u00e9s implique un positionnement strat\u00e9gique des d\u00e9tecteurs de pr\u00e9sence afin d\u2019assurer une couverture compl\u00e8te de l\u2019espace.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-18029\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Dans un local de stockage, les principales zones n\u00e9cessitant un \u00e9clairage sont les all\u00e9es principales et les all\u00e9es individuelles entre les \u00e9tag\u00e8res. Voici quelques recommandations \u00e0 suivre :<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>All\u00e9es principales<\/strong>: Installez des d\u00e9tecteurs de pr\u00e9sence au plafond \u00e0 intervalles r\u00e9guliers le long des principaux cheminements. Ces capteurs doivent \u00eatre r\u00e9gl\u00e9s en mode MARCHE automatique (Auto ON) et ARR\u00caT total (Full OFF), afin que les lumi\u00e8res s\u2019allument automatiquement lorsqu\u2019une personne entre dans le passage et s\u2019\u00e9teignent lorsque la zone est inoccup\u00e9e.<\/li>\n\n<li><strong>All\u00e9es individuelles<\/strong>: Pour les all\u00e9es individuelles entre les \u00e9tag\u00e8res, envisagez d\u2019installer des d\u00e9tecteurs de pr\u00e9sence muraux \u00e0 l\u2019entr\u00e9e de chaque all\u00e9e. Ces capteurs peuvent d\u00e9tecter lorsqu\u2019une personne entre dans l\u2019all\u00e9e et allumer les lumi\u00e8res en cons\u00e9quence. \u00c9tant donn\u00e9 l\u2019utilisation sporadique de ces all\u00e9es, les capteurs doivent \u00eatre r\u00e9gl\u00e9s en mode MARCHE manuelle (Manual ON) et ARR\u00caT total (Full OFF). Cela signifie que les lumi\u00e8res ne s\u2019allumeront que lorsqu\u2019elles seront actionn\u00e9es manuellement, mais s\u2019\u00e9teindront automatiquement lorsque l\u2019all\u00e9e sera inoccup\u00e9e.<\/li>\n\n<li><strong>Zone d\u2019entr\u00e9e<\/strong>: La zone d\u2019entr\u00e9e de la salle de stockage doit \u00eatre \u00e9quip\u00e9e d\u2019un interrupteur mural avec capteur permettant le contr\u00f4le manuel de tout l\u2019\u00e9clairage de la pi\u00e8ce. Cet interrupteur peut \u00eatre utilis\u00e9 pour allumer ou \u00e9teindre toutes les lumi\u00e8res selon les besoins, offrant un niveau de contr\u00f4le suppl\u00e9mentaire.<\/li>\n\n<li><strong>Consid\u00e9rations sur le placement des capteurs<\/strong>: Lors du placement des capteurs, assurez-vous qu\u2019ils ne sont pas situ\u00e9s pr\u00e8s des bouches d\u2019a\u00e9ration ou d\u2019autres sources de mouvement susceptibles de d\u00e9clencher de fausses d\u00e9tections. Assurez-vous \u00e9galement que le champ de vision des capteurs n\u2019est pas obstru\u00e9 par des \u00e9tag\u00e8res ou des objets stock\u00e9s.<\/li>\n\n<li><strong>Hauteur du capteur<\/strong>: Tenez compte de la hauteur d\u2019installation du capteur. Les capteurs doivent \u00eatre install\u00e9s \u00e0 une hauteur permettant une couverture optimale de la pi\u00e8ce, en tenant compte de la hauteur des articles stock\u00e9s.<\/li>\n\n<li><strong>Commande manuelle<\/strong>: Int\u00e9grez des commandes manuelles afin de permettre aux utilisateurs d\u2019allumer\/d\u2019\u00e9teindre tout l\u2019\u00e9clairage lorsque n\u00e9cessaire. Cela peut \u00eatre particuli\u00e8rement utile dans les salles de stockage o\u00f9 l\u2019\u00e9clairage peut \u00eatre requis pendant de longues p\u00e9riodes lors des contr\u00f4les d\u2019inventaire ou des t\u00e2ches de r\u00e9organisation.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produits et solutions phares<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/fr\/categorie-de-produit\/capteurs-de-mouvement\/detecteurs-de-mouvement-muraux\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interrupteurs de capteurs muraux<\/h3>\n\n<h4 class=\"wp-block-heading\">Interrupteurs \u00e0 d\u00e9tecteur de mouvement RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Options de c\u00e2blage \u00e0 2 fils, 3 fils, 4 fils <\/li>\n\n<li>Pr\u00e9sence, absence, marche\/arr\u00eat manuel<\/li>\n\n<li>Temporisation r\u00e9glable et contr\u00f4le de la lumi\u00e8re ambiante<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/fr\/categorie-de-produit\/capteurs-de-mouvement-sans-fil\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Capteurs muraux sans fil multi-emplacements<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interrupteur d\u00e9tecteur de pr\u00e9sence c\u00e2bl\u00e9 RZ021A\/022A<\/li>\n\n<li>Interrupteur compagnon sans fil (RZ022W) pour commande multi-emplacements<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/fr\/categorie-de-produit\/detecteurs-de-presence\/montage-au-plafond\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Capteurs de pr\u00e9sence au plafond<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>D\u00e9tecteurs de pr\u00e9sence c\u00e2bl\u00e9s<\/li>\n\n<li>Allumage automatique, extinction automatique <\/li>\n\n<li>Disponible en tension secteur et en basse tension<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Fonctionnalit\u00e9s principales incluses :<\/h3>\n\n<ul class=\"wp-block-list\"><li>Commande manuelle int\u00e9gr\u00e9e MARCHE\/ARR\u00caT pour tout l\u2019\u00e9clairage<\/li>\n\n<li>Capteurs de vacance (mise en marche manuelle uniquement) : les lumi\u00e8res doivent \u00eatre allum\u00e9es uniquement manuellement<\/li>\n\n<li>Temporisation r\u00e9glable, l\u2019\u00e9clairage s\u2019\u00e9teint automatiquement compl\u00e8tement apr\u00e8s 15 min<\/li>\n\n<li>En plus : kits sans fil multi-emplacements pour \u00e9tendre la port\u00e9e de commande sans rec\u00e2blage<\/li>\n\n<li>En plus : plusieurs options de c\u00e2blage disponibles pour les nouvelles constructions comme pour les projets de r\u00e9novation.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18028\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Conforme aux dispositions obligatoires<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Commandes par capteur de pr\u00e9sence<\/h4>\n\n<p>Des commandes par d\u00e9tecteur de pr\u00e9sence doivent \u00eatre install\u00e9es pour commander l\u2019\u00e9clairage dans l\u2019espace.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fonctions de commande des capteurs de pr\u00e9sence<\/h4>\n\n<ul class=\"wp-block-list\"><li>Allumage manuel ou allumage partiel \u00e0 une puissance ne d\u00e9passant pas 50%.<\/li>\n\n<li>Extinction compl\u00e8te dans les 20 minutes suivant le d\u00e9part de tous les occupants de l\u2019espace<\/li>\n\n<li>Une commande manuelle pour \u00e9teindre les lumi\u00e8res.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Commande locale<\/h4>\n\n<p>Il doit y avoir un ou plusieurs dispositifs de commande manuelle de l\u2019\u00e9clairage permettant la mise en marche et l\u2019arr\u00eat<br>de tout l\u2019\u00e9clairage dans l\u2019espace.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 H Commande d\u2019extinction totale automatique <\/h4>\n\n<p>Tout l\u2019\u00e9clairage de l\u2019espace doit \u00eatre automatiquement \u00e9teint dans les 20 minutes suivant le d\u00e9part de tous les occupants de l\u2019espace<\/p>\n\n<p>De plus, pour les salles de stockage de taille &lt;50 ft2 :<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Limit\u00e9 \u00e0 l\u2019allumage manuel<\/h4>\n\n<p>Aucun \u00e9clairage ne doit \u00eatre automatiquement allum\u00e9<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Titre 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Commandes manuelles de zone.<\/h4>\n\n<p>Chaque zone d\u00e9limit\u00e9e par des cloisons jusqu\u2019au plafond doit fournir des commandes d\u2019\u00e9clairage permettant d\u2019allumer et d\u2019\u00e9teindre manuellement l\u2019\u00e9clairage de cette zone.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Commandes d\u2019ARR\u00caT.<\/h4>\n\n<p>L\u2019\u00e9clairage doit \u00eatre command\u00e9 par des dispositifs de d\u00e9tection d\u2019occupation afin d\u2019\u00e9teindre automatiquement tout l\u2019\u00e9clairage en 20 minutes ou moins apr\u00e8s que la zone de commande est inoccup\u00e9e, et doit fonctionner soit comme :<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Commandes de d\u00e9tection de pr\u00e9sence (si 130.1(b) n\u2019exige pas des commandes d\u2019\u00e9clairage \u00e0 plusieurs niveaux) ; ou<\/li>\n\n<li>B. Commandes de d\u00e9tection de pr\u00e9sence avec allumage partiel, ou<\/li>\n\n<li>C. Commandes \u00e0 d\u00e9tection d\u2019absence, o\u00f9 tout l\u2019\u00e9clairage r\u00e9pond uniquement \u00e0 une entr\u00e9e d\u2019allumage manuel<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Dites-nous ce que vous en pensez.<\/h3>\n\n<p>Laissez Rayzeek vous aider \u00e0 concevoir et \u00e0 fournir une solution d\u2019\u00e9clairage \u00e9co\u00e9nerg\u00e9tique sur mesure.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/fr\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"formulaire de contact\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/fr\/wp-json\/wp\/v2\/pages\/18027#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Envoyer\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"fr\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Les locaux de stockage, souvent n\u00e9glig\u00e9s, sont des \u00e9l\u00e9ments essentiels des b\u00e2timents commerciaux. Ces espaces sont g\u00e9n\u00e9ralement remplis d\u2019\u00e9tag\u00e8res, de cartons et de divers objets, et servent \u00e0 stocker des fournitures, du mat\u00e9riel ou des documents archiv\u00e9s.<\/p>","protected":false},"author":1,"featured_media":18031,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-18027","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Storage Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-locaux-de-stockage\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Storage Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-locaux-de-stockage\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide\",\"name\":\"Storage Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T09:12:15+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/storage-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Storage Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Storage Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-locaux-de-stockage","og_locale":"fr_FR","og_type":"article","og_title":"Storage Room Energy Code Design Guide - Rayzeek","og_description":"Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents.","og_url":"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-locaux-de-stockage","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide","url":"https:\/\/www.rayzeek.com\/storage-room-design-guide","name":"Storage Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","datePublished":"2024-05-21T09:12:15+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/storage-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/storage-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/storage-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Storage Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages\/18027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/comments?post=18027"}],"version-history":[{"count":4,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages\/18027\/revisions"}],"predecessor-version":[{"id":18153,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages\/18027\/revisions\/18153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/media\/18031"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/media?parent=18027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}