{"id":17981,"date":"2024-05-21T08:20:43","date_gmt":"2024-05-21T08:20:43","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=17981"},"modified":"2024-06-05T02:22:27","modified_gmt":"2024-06-05T02:22:27","slug":"conference-room-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-salles-de-conference","title":{"rendered":"Guide de conception de salle de conf\u00e9rence"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-17983\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"conference-rooms\">Salles de conf\u00e9rence<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">D\u00e9couvrez le potentiel d\u2019\u00e9conomie d\u2019\u00e9nergie de votre salle de conf\u00e9rence gr\u00e2ce au guide de conception des d\u00e9tecteurs de pr\u00e9sence de Rayzeek.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1.jpg\" alt=\"\" class=\"wp-image-17984\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-1-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"maximize-energy-efficiency-in-conference-rooms-with-occupancy-sensors\">Maximisez l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique dans les salles de conf\u00e9rence avec des d\u00e9tecteurs de pr\u00e9sence<\/h2>\n\n<p>Les salles de conf\u00e9rence sont essentielles au fonctionnement de tout b\u00e2timent commercial, servant de centre n\u00e9vralgique pour les r\u00e9unions, les pr\u00e9sentations et les s\u00e9ances de brainstorming. Ces salles sont souvent \u00e9quip\u00e9es d\u2019un \u00e9clairage de forte intensit\u00e9 afin d\u2019assurer une bonne visibilit\u00e9 lors des pr\u00e9sentations et des discussions. Cependant, en raison de leur utilisation intermittente, elles sont sujettes \u00e0 un important gaspillage d\u2019\u00e9nergie. Les lumi\u00e8res sont souvent laiss\u00e9es allum\u00e9es lorsque la salle est inoccup\u00e9e, ce qui entra\u00eene une consommation d\u2019\u00e9nergie inutile.<\/p>\n\n<p>De plus, l\u2019utilisation sporadique des salles de conf\u00e9rence signifie qu\u2019elles restent souvent vacantes pendant de longues p\u00e9riodes, entra\u00eenant une consommation d\u2019\u00e9nergie inutile si les lumi\u00e8res restent allum\u00e9es. Ce gaspillage affecte non seulement l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique du b\u00e2timent, mais contribue \u00e9galement \u00e0 augmenter les co\u00fbts d\u2019exploitation.<\/p>\n\n<p>Avec les capteurs de pr\u00e9sence Rayzeek, vous pouvez transformer votre salle de conf\u00e9rence en un espace \u00e9conome en \u00e9nergie, r\u00e9pondre aux exigences des codes \u00e9nerg\u00e9tiques et contribuer \u00e0 un environnement plus respectueux de l\u2019environnement.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Respecter les codes \u00e9nerg\u00e9tiques<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>Le Code international de conservation de l\u2019\u00e9nergie (IECC) est un code mod\u00e8le \u00e9labor\u00e9 par l\u2019International Code Council (ICC) afin d\u2019\u00e9tablir des exigences minimales de conception et de construction en mati\u00e8re d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents. L\u2019IECC est mis \u00e0 jour tous les trois ans afin d\u2019int\u00e9grer les derni\u00e8res pratiques et technologies en mati\u00e8re de conservation de l\u2019\u00e9nergie.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC, pourquoi vous devriez vous en soucier<\/h3>\n\n<p>L\u2019IECC est largement adopt\u00e9 par les \u00c9tats et les municipalit\u00e9s \u00e0 travers les \u00c9tats-Unis. L\u2019IECC couvre divers aspects de la consommation d\u2019\u00e9nergie, notamment l\u2019enveloppe du b\u00e2timent (murs, toitures et fen\u00eatres), les syst\u00e8mes de chauffage et de refroidissement, ainsi que les syst\u00e8mes d\u2019\u00e9clairage.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>L\u2019IECC impose des commandes d\u2019\u00e9clairage sp\u00e9cifiques, telles que des d\u00e9tecteurs de pr\u00e9sence, afin de minimiser le gaspillage d\u2019\u00e9nergie dans les espaces inoccup\u00e9s dans diverses zones.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>La norme ANSI\/ASHRAE\/IES 90.1, Norme \u00e9nerg\u00e9tique pour les sites et les b\u00e2timents \u00e0 l\u2019exception des b\u00e2timents r\u00e9sidentiels de faible hauteur, est une norme \u00e9nerg\u00e9tique largement reconnue publi\u00e9e par l\u2019American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1 : pourquoi vous devriez vous en soucier<\/h3>\n\n<p>L\u2019ASHRAE 90.1 est utilis\u00e9e comme r\u00e9f\u00e9rence pour les codes \u00e9nerg\u00e9tiques du b\u00e2timent \u00e0 travers les \u00c9tats-Unis et sert de voie de conformit\u00e9 dans l\u2019IECC, qui d\u00e9finit des exigences minimales de performance \u00e9co\u00e9nerg\u00e9tique des composants des b\u00e2timents commerciaux, notamment les enveloppes du b\u00e2timent, les syst\u00e8mes CVC, les syst\u00e8mes de chauffage de l\u2019eau et les syst\u00e8mes d\u2019\u00e9clairage. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>La norme ASHRAE 90.1 sp\u00e9cifie les densit\u00e9s de puissance d\u2019\u00e9clairage maximales autoris\u00e9es et les exigences minimales en mati\u00e8re de commande d\u2019\u00e9clairage, y compris l\u2019utilisation de capteurs de pr\u00e9sence dans des zones sp\u00e9cifiques.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>Le Titre 24, partie 6 du California Building Standards Code, officiellement appel\u00e9 \u00ab Building Energy Efficiency Standards for Residential and Nonresidential Buildings \u00bb, est administr\u00e9 par la California Energy Commission et est mis \u00e0 jour p\u00e9riodiquement afin de refl\u00e9ter les nouvelles technologies et m\u00e9thodes d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique.<\/p>\n\n<h3 class=\"wp-block-heading\">Titre 24, pourquoi vous devriez vous en soucier<\/h3>\n\n<p>Le Titre 24 est connu pour ses exigences rigoureuses, souvent consid\u00e9r\u00e9es comme plus strictes que celles de nombreux autres codes \u00e9nerg\u00e9tiques aux \u00c9tats-Unis. Le Titre 24 impose des normes strictes de performance \u00e9nerg\u00e9tique pour tous les aspects de la construction des b\u00e2timents, notamment le chauffage, la ventilation, la climatisation (CVC), le chauffage de l\u2019eau et l\u2019\u00e9clairage.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Le Titre 24 exige l\u2019installation de capteurs d\u2019occupation qui ajustent l\u2019\u00e9clairage en fonction de l\u2019occupation des pi\u00e8ces dans certaines zones des b\u00e2timents commerciaux afin d\u2019\u00e9viter tout gaspillage d\u2019\u00e9nergie.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Adoption des codes \u00e9nerg\u00e9tiques par \u00c9tat<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">D\u00e9veloppez pour voir le tableau d\u00e9taill\u00e9 \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u00c9tat<\/th><th>Code commercial en vigueur<\/th><th>Cat\u00e9gorie d\u2019efficacit\u00e9 du code commercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Aucun \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Arizona<\/td><td>Autonomie locale<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 et 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Californie<\/td><td>Normes d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique des b\u00e2timents 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 et 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>District de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Floride<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>G\u00e9orgie<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Hawa\u00ef<\/td><td>Autonomie locale<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 et 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 et 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 et 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Louisiane<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 et 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Michigan<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Mississippi<\/td><td>Aucun \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Missouri<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 et 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Hampshire<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>New Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nouveau-Mexique<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>New York<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Caroline du Nord<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota du Nord<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 et 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oregon<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pennsylvanie<\/td><td>IECC 2018 et 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Caroline du Sud<\/td><td>IECC 2009 et 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota du Sud<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 et 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 et 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginie<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Code de l\u2019\u00e9nergie de l\u2019\u00c9tat de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 et 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 et 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 et 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginie<\/td><td>IECC 2021 et 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>Code de l\u2019\u00e9nergie de l\u2019\u00c9tat de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginie-Occidentale<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 et 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonomie locale<\/td><td>Aucun code \u00e0 l\u2019\u00e9chelle de l\u2019\u00c9tat<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Lorsqu\u2019un amendement ayant un impact sur l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique peut \u00eatre quantifi\u00e9 \u00e0 l\u2019aide des mod\u00e8les de b\u00e2timents prototypes du DOE, il a \u00e9t\u00e9 pris en compte dans l\u2019analyse.<\/li>\n\n<li>Pour les \u00c9tats adoptant \u00e0 la fois l\u2019IECC et la norme 90.1, le code IECC est g\u00e9n\u00e9ralement analys\u00e9 comme le code en vigueur de l\u2019\u00c9tat dans cette \u00e9tude, sauf pour les \u00c9tats ayant des amendements importants \u00e0 l\u2019IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Solutions de capteurs<\/h4>\n\n<p>D\u00e9couvrez comment Rayzeek peut r\u00e9soudre vos d\u00e9fis en mati\u00e8re d\u2019\u00e9conomies d\u2019\u00e9nergie.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/fr\/produits\"><div class=\"offering_button\"><p>Voir toutes les offres<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-conference-rooms\">Concepts cl\u00e9s du guide de conception pour les salles de conf\u00e9rence<\/h2>\n\n<p>Concevoir une solution de commande d\u2019\u00e9clairage \u00e9co\u00e9nerg\u00e9tique pour les salles de conf\u00e9rence implique un placement strat\u00e9gique des d\u00e9tecteurs de pr\u00e9sence afin d\u2019assurer une couverture compl\u00e8te de l\u2019espace.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3.jpg\" alt=\"\" class=\"wp-image-17986\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>Concevoir un syst\u00e8me d\u2019\u00e9clairage \u00e9co\u00e9nerg\u00e9tique pour une salle de conf\u00e9rence implique un placement strat\u00e9gique des d\u00e9tecteurs de pr\u00e9sence afin d\u2019assurer une couverture compl\u00e8te. Voici quelques recommandations \u00e0 prendre en compte :<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Couverture des entr\u00e9es<\/strong>: Installez un capteur mural pr\u00e8s de l\u2019entr\u00e9e pour d\u00e9tecter quand quelqu\u2019un entre ou sort de la salle. Ce capteur doit \u00eatre plac\u00e9 suffisamment haut pour \u00e9viter d\u2019\u00eatre obstru\u00e9 par la porte ouverte et ne doit pas faire directement face \u00e0 l\u2019entr\u00e9e afin d\u2019\u00e9viter les d\u00e9clenchements intempestifs dus aux mouvements \u00e0 l\u2019ext\u00e9rieur de la salle.<\/li>\n\n<li><strong>Couverture de table<\/strong>: Placez un capteur mont\u00e9 au plafond au-dessus de la table de conf\u00e9rence afin de d\u00e9tecter la pr\u00e9sence dans la zone principale de la salle. Ce capteur doit \u00eatre positionn\u00e9 au centre pour assurer une couverture compl\u00e8te.<\/li>\n\n<li><strong>Couverture de la zone de pr\u00e9sentation<\/strong>: Si votre salle de conf\u00e9rence dispose d\u2019une zone de pr\u00e9sentation d\u00e9di\u00e9e, envisagez d\u2019installer un capteur mural suppl\u00e9mentaire pour couvrir cet espace. Ce capteur doit \u00eatre positionn\u00e9 de mani\u00e8re \u00e0 \u00e9viter toute obstruction potentielle, comme des \u00e9crans ou des projecteurs.<\/li>\n\n<li><strong>Commande murale<\/strong>: Installez une unit\u00e9 de commande murale pr\u00e8s de l\u2019entr\u00e9e pour une commande manuelle (override) ou des ajustements des r\u00e9glages d\u2019\u00e9clairage. Cette commande doit \u00eatre facilement accessible lors de l\u2019entr\u00e9e ou de la sortie de la salle.<\/li>\n\n<li><strong>\u00c9vitement des obstructions et des interf\u00e9rences<\/strong>: Veillez \u00e0 ne pas placer les capteurs pr\u00e8s des bouches d\u2019a\u00e9ration afin d\u2019\u00e9viter les interf\u00e9rences dues aux flux d\u2019air ou aux vibrations. Tenez \u00e9galement compte de la hauteur et de l\u2019emplacement du mobilier pour \u00e9viter d\u2019obstruer le champ de vision du capteur.<\/li>\n\n<li><strong>Int\u00e9gration aux syst\u00e8mes existants<\/strong>: Nos capteurs de pr\u00e9sence peuvent \u00eatre int\u00e9gr\u00e9s aux syst\u00e8mes d\u2019\u00e9clairage existants pour un fonctionnement fluide. Ils peuvent \u00e9galement \u00eatre programm\u00e9s pour \u00e9teindre toutes les lumi\u00e8res apr\u00e8s une certaine p\u00e9riode d\u2019inactivit\u00e9, am\u00e9liorant ainsi davantage l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Produits et solutions phares<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/fr\/categorie-de-produit\/capteurs-de-mouvement\/detecteurs-de-mouvement-muraux\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interrupteurs de capteurs muraux<\/h3>\n\n<h4 class=\"wp-block-heading\">Interrupteurs \u00e0 d\u00e9tecteur de mouvement RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Options de c\u00e2blage \u00e0 2 fils, 3 fils, 4 fils <\/li>\n\n<li>Pr\u00e9sence, absence, marche\/arr\u00eat manuel<\/li>\n\n<li>Temporisation r\u00e9glable et contr\u00f4le de la lumi\u00e8re ambiante<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/fr\/categorie-de-produit\/capteurs-de-mouvement-sans-fil\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Capteurs muraux sans fil multi-emplacements<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interrupteur d\u00e9tecteur de pr\u00e9sence c\u00e2bl\u00e9 RZ021A\/022A<\/li>\n\n<li>Interrupteur compagnon sans fil (RZ022W) pour commande multi-emplacements<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/fr\/categorie-de-produit\/detecteurs-de-presence\/montage-au-plafond\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Capteurs de pr\u00e9sence au plafond<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>D\u00e9tecteurs de pr\u00e9sence c\u00e2bl\u00e9s<\/li>\n\n<li>Allumage automatique, extinction automatique <\/li>\n\n<li>Disponible en tension secteur et en basse tension<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Fonctionnalit\u00e9s principales incluses :<\/h3>\n\n<ul class=\"wp-block-list\"><li>Commande manuelle int\u00e9gr\u00e9e MARCHE\/ARR\u00caT pour tout l\u2019\u00e9clairage<\/li>\n\n<li>Capteurs de vacance (mise en marche manuelle uniquement) : les lumi\u00e8res doivent \u00eatre allum\u00e9es uniquement manuellement<\/li>\n\n<li>Temporisation r\u00e9glable, l\u2019\u00e9clairage s\u2019\u00e9teint automatiquement compl\u00e8tement apr\u00e8s 15 min<\/li>\n\n<li>En plus : kits sans fil multi-emplacements pour \u00e9tendre la port\u00e9e de commande sans rec\u00e2blage<\/li>\n\n<li>En plus : plusieurs options de c\u00e2blage disponibles pour les nouvelles constructions comme pour les projets de r\u00e9novation.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4.jpg\" alt=\"\" class=\"wp-image-17982\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Conforme aux dispositions obligatoires<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Commandes par capteur de pr\u00e9sence<\/h4>\n\n<p>Des commandes par d\u00e9tecteur de pr\u00e9sence doivent \u00eatre install\u00e9es pour commander l\u2019\u00e9clairage dans l\u2019espace.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Fonctions de commande des capteurs de pr\u00e9sence<\/h4>\n\n<ul class=\"wp-block-list\"><li>Allumage manuel ou allumage partiel \u00e0 une puissance ne d\u00e9passant pas 50%.<\/li>\n\n<li>Extinction compl\u00e8te dans les 20 minutes suivant le d\u00e9part de tous les occupants de l\u2019espace<\/li>\n\n<li>Une commande manuelle pour \u00e9teindre les lumi\u00e8res.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Commande locale<\/h4>\n\n<p>Il doit y avoir un ou plusieurs dispositifs de commande manuelle de l\u2019\u00e9clairage permettant la mise en marche et l\u2019arr\u00eat<br>de tout l\u2019\u00e9clairage dans l\u2019espace.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-b-restricted-to-manual-on\">9.4.1.1 b Limit\u00e9 \u00e0 l\u2019allumage manuel<\/h4>\n\n<p>Aucun \u00e9clairage ne doit \u00eatre automatiquement allum\u00e9<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-c-restricted-to-partial-automatic-on\">9.4.1.1 c Limit\u00e9 \u00e0 un allumage automatique partiel<\/h4>\n\n<p>Pas plus de 50% de la puissance d\u2019\u00e9clairage pour l\u2019\u00e9clairage g\u00e9n\u00e9ral ne doit \u00eatre autoris\u00e9e \u00e0 \u00eatre automatiquement allum\u00e9e<\/p>\n\n<p>** REMARQUE : Au moins un 9.4.1.1 b ou 9.4.1.1 c doit \u00eatre mis en \u0153uvre.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Commande d\u2019extinction totale automatique <\/h4>\n\n<p>Tout l\u2019\u00e9clairage de l\u2019espace doit \u00eatre automatiquement \u00e9teint dans les 20 minutes suivant le d\u00e9part de tous les occupants de l\u2019espace<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">Titre 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Commandes manuelles de zone.<\/h4>\n\n<p>Chaque zone d\u00e9limit\u00e9e par des cloisons jusqu\u2019au plafond doit fournir des commandes d\u2019\u00e9clairage permettant d\u2019allumer et d\u2019\u00e9teindre manuellement l\u2019\u00e9clairage de cette zone.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Commandes d\u2019ARR\u00caT.<\/h4>\n\n<p>L\u2019\u00e9clairage doit \u00eatre command\u00e9 par des dispositifs de d\u00e9tection d\u2019occupation afin d\u2019\u00e9teindre automatiquement tout l\u2019\u00e9clairage en 20 minutes ou moins apr\u00e8s que la zone de commande est inoccup\u00e9e, et doit fonctionner soit comme :<\/p>\n\n<ul class=\"wp-block-list\"><li>A. Commandes de d\u00e9tection de pr\u00e9sence (si 130.1(b) n\u2019exige pas des commandes d\u2019\u00e9clairage \u00e0 plusieurs niveaux) ; ou<\/li>\n\n<li>B. Commandes de d\u00e9tection de pr\u00e9sence avec allumage partiel, ou<\/li>\n\n<li>C. Commandes \u00e0 d\u00e9tection d\u2019absence, o\u00f9 tout l\u2019\u00e9clairage r\u00e9pond uniquement \u00e0 une entr\u00e9e d\u2019allumage manuel<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Dites-nous ce que vous en pensez.<\/h3>\n\n<p>Laissez Rayzeek vous aider \u00e0 concevoir et \u00e0 fournir une solution d\u2019\u00e9clairage \u00e9co\u00e9nerg\u00e9tique sur mesure.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/fr\/wp-json\/wp\/v2\/pages\/17981#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"formulaire de contact\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/fr\/wp-json\/wp\/v2\/pages\/17981#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Envoyer\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"fr\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Les salles de conf\u00e9rence sont essentielles au fonctionnement de tout b\u00e2timent commercial, servant de centre n\u00e9vralgique pour les r\u00e9unions, les pr\u00e9sentations et les s\u00e9ances de brainstorming.<\/p>","protected":false},"author":1,"featured_media":17983,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-17981","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Conference Room Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-salles-de-conference\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conference Room Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-salles-de-conference\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide\",\"name\":\"Conference Room Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:20:43+00:00\",\"dateModified\":\"2024-06-05T02:22:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/conference-room-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/conference-room-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conference Room Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conference Room Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-salles-de-conference","og_locale":"fr_FR","og_type":"article","og_title":"Conference Room Energy Code Design Guide - Rayzeek","og_description":"Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions.","og_url":"https:\/\/www.rayzeek.com\/fr\/guide-de-conception-des-salles-de-conference","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:27+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/conference-room-design-guide","url":"https:\/\/www.rayzeek.com\/conference-room-design-guide","name":"Conference Room Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/conference-room-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/conference-room-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","datePublished":"2024-05-21T08:20:43+00:00","dateModified":"2024-06-05T02:22:27+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/conference-room-design-guide#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/conference-room-design-guide"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.rayzeek.com\/conference-room-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/conference-room-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/conference-room-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Conference Room Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages\/17981","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/comments?post=17981"}],"version-history":[{"count":7,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages\/17981\/revisions"}],"predecessor-version":[{"id":18159,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/pages\/17981\/revisions\/18159"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/media\/17983"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/fr\/wp-json\/wp\/v2\/media?parent=17981"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}