{"id":17996,"date":"2024-05-21T08:41:22","date_gmt":"2024-05-21T08:41:22","guid":{"rendered":"https:\/\/www.rayzeek.com\/?page_id=17996"},"modified":"2024-06-05T02:22:38","modified_gmt":"2024-06-05T02:22:38","slug":"corridor-design-guide","status":"publish","type":"page","link":"https:\/\/www.rayzeek.com\/es\/guia-de-diseno-de-corredores","title":{"rendered":"Gu\u00eda de dise\u00f1o de pasillos"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light rzpg_header_cover\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-0 has-background-dim\"><\/span><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-17998\" alt=\"\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg 1920w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-300x78.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1024x267.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-768x200.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1536x400.jpg 1536w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-18x5.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner-1200x313.jpg 1200w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h1 class=\"wp-block-heading\" id=\"corridors\">Pasillos<\/h1>\n\n<p class=\"has-text-align-left has-large-font-size\">Descubra el potencial de ahorro energ\u00e9tico de los pasillos con la gu\u00eda de dise\u00f1o de sensores de ocupaci\u00f3n de Rayzeek. Descubra el poder del control automatizado de la iluminaci\u00f3n en los pasadizos de su edificio comercial.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_area rzpg_area_liner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4.jpg\" alt=\"\" class=\"wp-image-17997\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-4-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\" id=\"lighting-the-way-to-energy-efficiency-in-corridors\">Iluminando el camino hacia la eficiencia energ\u00e9tica en pasillos<\/h2>\n\n<p>Los pasillos, ya sea en edificios comerciales, instituciones educativas o centros sanitarios, son zonas de mucho tr\u00e1nsito que a menudo permanecen iluminadas durante todo el d\u00eda, lo que conlleva un consumo energ\u00e9tico significativo. Estos espacios suelen utilizar iluminaci\u00f3n fluorescente o LED, que, aunque es eficiente energ\u00e9ticamente, puede seguir contribuyendo a costes energ\u00e9ticos elevados cuando se deja encendida innecesariamente.<\/p>\n\n<p>El desaf\u00edo radica en que los pasillos se ocupan de forma intermitente, con periodos de mucho tr\u00e1nsito intercalados con momentos de vacancia. Los controles manuales de iluminaci\u00f3n tradicionales pueden provocar que las luces se queden encendidas durante esos periodos de vacancia, lo que conlleva un desperdicio energ\u00e9tico innecesario.<\/p>\n\n<p>Al integrar nuestros sensores de ocupaci\u00f3n en su sistema de iluminaci\u00f3n de pasillos, puede garantizar que las luces solo est\u00e9n encendidas cuando sea necesario, ahorrando energ\u00eda y reduciendo costes. Nuestros sensores, incluidas opciones de pared y de techo, est\u00e1n dise\u00f1ados para cumplir con los C\u00f3digos Energ\u00e9ticos de EE. UU., lo que los convierte en un componente esencial para cumplir los requisitos de eficiencia energ\u00e9tica en edificios comerciales.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_codes_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Conozca los c\u00f3digos energ\u00e9ticos<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_codes\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"382\" height=\"148\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg\" alt=\"\" class=\"wp-image-17809\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc.jpg 382w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-300x116.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/iecc-18x7.jpg 18w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/figure>\n\n<p>El International Energy Conservation Code (IECC) es un c\u00f3digo modelo desarrollado por el International Code Council (ICC) para establecer requisitos m\u00ednimos de dise\u00f1o y construcci\u00f3n en materia de eficiencia energ\u00e9tica en los edificios. El IECC se actualiza cada tres a\u00f1os para incorporar las \u00faltimas pr\u00e1cticas y tecnolog\u00edas de conservaci\u00f3n de energ\u00eda.<\/p>\n\n<h3 class=\"wp-block-heading\">IECC: por qu\u00e9 deber\u00eda importarle<\/h3>\n\n<p>El IECC est\u00e1 ampliamente adoptado por estados y municipios de todo Estados Unidos. El IECC abarca varios aspectos del uso de la energ\u00eda, incluidos la envolvente del edificio (paredes, cubiertas y ventanas), los sistemas de calefacci\u00f3n y refrigeraci\u00f3n, y los sistemas de iluminaci\u00f3n.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>El IECC exige controles de iluminaci\u00f3n espec\u00edficos, como sensores de ocupaci\u00f3n, para minimizar el desperdicio de energ\u00eda en espacios desocupados en diversas \u00e1reas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg\" alt=\"\" class=\"wp-image-17810\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-1024x576.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-300x169.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-768x432.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo-18x10.jpg 18w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/ashrae-logo.jpg 1170w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>La norma ANSI\/ASHRAE\/IES 90.1, Norma energ\u00e9tica para emplazamientos y edificios excepto edificios residenciales de baja altura, es una norma energ\u00e9tica ampliamente reconocida publicada por la American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).<\/p>\n\n<h3 class=\"wp-block-heading\">ASHRAE 90.1, por qu\u00e9 deber\u00eda importarte<\/h3>\n\n<p>ASHRAE 90.1 se utiliza como referencia para los c\u00f3digos energ\u00e9ticos de edificaci\u00f3n en todo Estados Unidos y sirve como v\u00eda de cumplimiento dentro del IECC, que establece los requisitos m\u00ednimos para el rendimiento energ\u00e9ticamente eficiente de los componentes de los edificios comerciales, incluidos la envolvente del edificio, los sistemas HVAC, los sistemas de calentamiento de agua y los sistemas de iluminaci\u00f3n. <\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>La norma ASHRAE 90.1 especifica las densidades m\u00e1ximas permitidas de potencia de iluminaci\u00f3n y los requisitos m\u00ednimos de control de iluminaci\u00f3n, incluido el uso de sensores de ocupaci\u00f3n en \u00e1reas espec\u00edficas.<\/strong><\/p><\/blockquote><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"398\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg\" alt=\"\" class=\"wp-image-17811\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo.jpg 400w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-300x299.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/Title24-logo-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n<p>El T\u00edtulo 24, parte 6 del California Building Standards Code, conocido oficialmente como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, es administrado por la California Energy Commission y se actualiza peri\u00f3dicamente para reflejar nuevas tecnolog\u00edas y m\u00e9todos de eficiencia energ\u00e9tica.<\/p>\n\n<h3 class=\"wp-block-heading\">T\u00edtulo 24, por qu\u00e9 deber\u00eda importarte<\/h3>\n\n<p>El T\u00edtulo 24 es conocido por sus rigurosos requisitos, a menudo considerados m\u00e1s estrictos que los de muchos otros c\u00f3digos energ\u00e9ticos de Estados Unidos. El T\u00edtulo 24 exige estrictos est\u00e1ndares de rendimiento energ\u00e9tico para todos los aspectos de la construcci\u00f3n de edificios, lo que incluye calefacci\u00f3n, ventilaci\u00f3n, aire acondicionado (HVAC), calentamiento de agua e iluminaci\u00f3n.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>El T\u00edtulo 24 requiere la instalaci\u00f3n de sensores de ocupaci\u00f3n que ajusten la iluminaci\u00f3n en funci\u00f3n de la ocupaci\u00f3n de la sala en \u00e1reas espec\u00edficas de los edificios comerciales para garantizar que no se desperdicie energ\u00eda.<\/strong><\/p><\/blockquote><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_state_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-center\">Adopci\u00f3n del c\u00f3digo energ\u00e9tico por estado<\/h2>\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"515\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg\" alt=\"\" class=\"wp-image-17765\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map.jpg 879w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-300x176.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-768x450.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-by-state-map-18x12.jpg 18w\" sizes=\"(max-width: 879px) 100vw, 879px\" \/><\/figure><\/div>\n\n<div id=\"rzpg_states_id\" class=\"wp-block-group table_hide\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p class=\"has-text-align-center\">Expanda para ver la tabla detallada \u2193<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Estado<\/th><th>C\u00f3digo comercial vigente<\/th><th>Categor\u00eda de eficiencia del c\u00f3digo comercial<\/th><\/tr><\/thead><tbody><tr><td>Alabama<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Alaska<\/td><td>Ninguno a nivel estatal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Arizona<\/td><td>Autonom\u00eda municipal<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Arkansas<\/td><td>IECC 2009 y 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>California<\/td><td>Normas de Eficiencia Energ\u00e9tica de Edificios 2022<\/td><td>90.1-2019<\/td><\/tr><tr><td>Colorado<\/td><td>Autonom\u00eda municipal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Connecticut<\/td><td>IECC 2021 y 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Delaware<\/td><td>IECC 2018 y 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Distrito de Columbia<\/td><td>90.1-2013^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Florida<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Georgia<\/td><td>IECC 2015 y 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Haw\u00e1i<\/td><td>Autonom\u00eda municipal<\/td><td>90.1-2013<\/td><\/tr><tr><td>Idaho<\/td><td>IECC 2018 y 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Illinois<\/td><td>IECC 2021 y 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Indiana<\/td><td>90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Iowa<\/td><td>IECC 2012 y 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Kansas<\/td><td>Autonom\u00eda municipal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Kentucky<\/td><td>IECC 2012 y 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Luisiana<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Maine<\/td><td>IECC 2015 y 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Maryland<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Massachusetts<\/td><td>IECC 2018 y 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>M\u00edchigan<\/td><td>IECC 2015 y 90.1-2013^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Minnesota<\/td><td>90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Misisipi<\/td><td>Ninguno a nivel estatal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Misuri<\/td><td>Autonom\u00eda municipal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Montana<\/td><td>IECC 2021 y 90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nebraska<\/td><td>IECC 2018 y 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nevada<\/td><td>IECC 2018 y 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nuevo Hampshire<\/td><td>IECC 2018 y 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Nueva Jersey<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nuevo M\u00e9xico<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Nueva York<\/td><td>IECC 2018 y 90.1-2016^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Carolina del Norte<\/td><td>IECC 2015 y 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Dakota del Norte<\/td><td>Autonom\u00eda municipal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Ohio<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2016<\/td><\/tr><tr><td>Oklahoma<\/td><td>IECC 2006 y 90.1-2004<\/td><td>&lt;90.1-2007<\/td><\/tr><tr><td>Oreg\u00f3n<\/td><td>90.1-2019<\/td><td>90.1-2019<\/td><\/tr><tr><td>Pensilvania<\/td><td>IECC 2018 y 90.1-2016<\/td><td>90.1-2013<\/td><\/tr><tr><td>Rhode Island<\/td><td>IECC 2018 y 90.1-2016^<\/td><td>90.1-2013<\/td><\/tr><tr><td>Carolina del Sur<\/td><td>IECC 2009 y 90.1-2007<\/td><td>90.1-2007<\/td><\/tr><tr><td>Dakota del Sur<\/td><td>Autonom\u00eda municipal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2021 y 90.1-2013<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 y 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico del Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Tennessee<\/td><td>IECC 2012 y 90.1-2010<\/td><td>90.1-2007<\/td><\/tr><tr><td>Texas<\/td><td>IECC 2015 y 90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Utah<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Vermont<\/td><td>IECC 2018 y 90.1-2016^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia<\/td><td>IECC 2021 y 90.1-2019^<\/td><td>90.1-2019<\/td><\/tr><tr><td>Washington<\/td><td>C\u00f3digo Energ\u00e9tico del Estado de Washington 2018<\/td><td>90.1-2019<\/td><\/tr><tr><td>Virginia Occidental<\/td><td>90.1-2013<\/td><td>90.1-2013<\/td><\/tr><tr><td>Wisconsin<\/td><td>IECC 2015 y 90.1-2013^<\/td><td>90.1-2010<\/td><\/tr><tr><td>Wyoming<\/td><td>Autonom\u00eda municipal<\/td><td>Sin c\u00f3digo estatal<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ul class=\"wp-block-list\"><li>^ Cuando una enmienda que afecta a la eficiencia energ\u00e9tica puede cuantificarse mediante los Modelos de Edificios Prototipo del DOE, se incluy\u00f3 en el an\u00e1lisis.<\/li>\n\n<li>Para los estados que adoptan tanto el IECC como la 90.1, el c\u00f3digo IECC suele analizarse como el c\u00f3digo estatal vigente en este estudio, excepto en los estados con amplias enmiendas al IECC.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_all_offerings_group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h4 class=\"wp-block-heading\">Soluciones de sensores<\/h4>\n\n<p>Descubra c\u00f3mo Rayzeek puede resolver sus retos de ahorro energ\u00e9tico.<\/p>\n\n<a  href=\"https:\/\/www.rayzeek.com\/es\/productos\"><div class=\"offering_button\"><p>Ver todas las opciones<\/p><\/div><\/a><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"design-guide-key-concepts-for-corridors\">Conceptos clave de la gu\u00eda de dise\u00f1o para pasillos<\/h2>\n\n<p>Dise\u00f1ar una soluci\u00f3n de control de iluminaci\u00f3n energ\u00e9ticamente eficiente para pasillos implica la colocaci\u00f3n estrat\u00e9gica de sensores de ocupaci\u00f3n para garantizar una cobertura completa del espacio.<\/p><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_design\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2.jpg\" alt=\"\" class=\"wp-image-18000\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-2-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><p>En un pasillo, el objetivo principal es garantizar un paso seguro y bien iluminado para los ocupantes, minimizando al mismo tiempo el derroche de energ\u00eda, y que todos los puntos de acceso potenciales y toda la longitud del pasillo est\u00e9n cubiertos por los sensores. Estas son algunas consideraciones de dise\u00f1o:<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>Ubicaci\u00f3n del sensor<\/strong>: Para pasillos largos, pueden ser necesarios varios sensores. Los sensores montados en el techo pueden colocarse a intervalos regulares a lo largo del pasillo para garantizar una cobertura completa. Alternativamente, los sensores montados en la pared pueden colocarse en ambos extremos del pasillo, con sus \u00e1reas de cobertura superponi\u00e9ndose en el centro para evitar puntos ciegos. Adem\u00e1s, tenga en cuenta la altura y el alcance de los sensores para asegurarse de que puedan detectar eficazmente el movimiento a lo largo de todo el pasillo.<\/li>\n\n<li><strong>Tipo de sensor<\/strong>: Dependiendo de la altura del techo y de la presencia de posibles obstrucciones, se pueden utilizar sensores montados en el techo o en la pared. Los sensores de techo de Rayzeek ofrecen encendido autom\u00e1tico y apagado completo autom\u00e1tico, mientras que nuestros sensores de pared ofrecen encendido manual y apagado completo autom\u00e1tico.<\/li>\n\n<li><strong>Controles manuales adicionales<\/strong>: Adem\u00e1s de los sensores de ocupaci\u00f3n, se pueden integrar controles manuales para los casos en los que sea necesario un anulado manual. Estos controles pueden ubicarse de forma conveniente cerca de las entradas o salidas.<\/li>\n\n<li><strong>Evitar activaciones falsas<\/strong>: Los sensores deben colocarse de manera que no queden orientados directamente hacia puertas que conduzcan a otros espacios, fuentes de luz externas y rejillas de ventilaci\u00f3n, ya que esto podr\u00eda provocar activaciones falsas cuando se detecte movimiento en esos espacios adyacentes.<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_design_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading has-text-align-left\" id=\"featured-products-amp-solutions\">Productos y soluciones destacados<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_products rzpg_products_4\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/es\/categoria-de-producto\/sensores-de-movimiento\/sensores-de-movimiento-de-montaje-en-pared\"><img loading=\"lazy\" decoding=\"async\" width=\"740\" height=\"740\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png\" alt=\"\" class=\"wp-image-10128\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021.png 740w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-300x300.png 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-100x100.png 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-150x150.png 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/04\/front-wall-switch-021-600x600.png 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Interruptores con sensor de pared<\/h3>\n\n<h4 class=\"wp-block-heading\">Interruptores con sensor de movimiento RZ020\/021<\/h4>\n\n<ul class=\"wp-block-list\"><li>Opciones de cableado de 2 hilos, 3 hilos y 4 hilos <\/li>\n\n<li>Ocupaci\u00f3n, vacancia, ENCENDIDO\/APAGADO manual<\/li>\n\n<li>Retardo de tiempo ajustable y control de luz ambiental<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.rayzeek.com\/es\/categoria-de-producto\/sensores-de-movimiento-inalambricos\/?filters=mounting[74]\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg\" alt=\"\" class=\"wp-image-13078\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit-600x600.jpg 600w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2023\/07\/020-022w-kit.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores inal\u00e1mbricos de pared para m\u00faltiples ubicaciones<\/h3>\n\n<h4 class=\"wp-block-heading\">Kits RZ020A\/021A + RZ022W<\/h4>\n\n<ul class=\"wp-block-list\"><li>Interruptor con sensor de ocupaci\u00f3n cableado RZ021A\/022A<\/li>\n\n<li>Interruptor complementario inal\u00e1mbrico (RZ022W) para control desde m\u00faltiples ubicaciones<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.rayzeek.com\/es\/categoria-de-producto\/sensores-de-ocupacion\/montaje-en-el-techo\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"927\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg\" alt=\"\" class=\"wp-image-9471\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card.jpg 927w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2022\/03\/occupancy-sensor-rz036-front-card-600x600.jpg 600w\" sizes=\"(max-width: 927px) 100vw, 927px\" \/><\/a><\/figure>\n\n<h3 class=\"wp-block-heading\">Sensores de ocupaci\u00f3n de techo<\/h3>\n\n<h4 class=\"wp-block-heading\">RZ036<\/h4>\n\n<ul class=\"wp-block-list\"><li>Sensores de ocupaci\u00f3n cableados<\/li>\n\n<li>Encendido autom\u00e1tico, apagado autom\u00e1tico <\/li>\n\n<li>Disponible en tensi\u00f3n de red y baja tensi\u00f3n<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_solution\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"core-features-included\">Funciones principales incluidas:<\/h3>\n\n<ul class=\"wp-block-list\"><li>Control manual integrado de ENCENDIDO\/APAGADO para toda la iluminaci\u00f3n<\/li>\n\n<li>Sensores de vacancia (solo ENCENDIDO manual): Las luces deben encenderse \u00fanicamente de forma manual<\/li>\n\n<li>Retardo de tiempo ajustable, la iluminaci\u00f3n se apaga autom\u00e1ticamente por completo despu\u00e9s de 15 min<\/li>\n\n<li>Adicional: kits inal\u00e1mbricos multubicaci\u00f3n para ampliar el alcance del control sin recablear<\/li>\n\n<li>Adicional: m\u00faltiples opciones de cableado disponibles tanto para nuevas construcciones como para proyectos de rehabilitaci\u00f3n.<\/li><\/ul><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3.jpg\" alt=\"\" class=\"wp-image-18001\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3.jpg 1000w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-3-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory_headline\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h2 class=\"wp-block-heading\">Cumple las disposiciones obligatorias<\/h2><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_mandatory\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"iecc-2011\">IECC \u2013 2011<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"c40521-occupant-sensor-controls\">C405.2.1 Controles por sensor de ocupaci\u00f3n<\/h4>\n\n<p>Se instalar\u00e1n controles con sensor de ocupantes para controlar las luces del espacio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405211-occupant-sensor-control-functions\">C405.2.1.1 Funciones de control del sensor de ocupaci\u00f3n<\/h4>\n\n<ul class=\"wp-block-list\"><li>Encendido manual o encendido parcial a no m\u00e1s del 50% de potencia.<\/li>\n\n<li>Apagado completo en un plazo de 20 minutos despu\u00e9s de que todos los ocupantes hayan abandonado el espacio<\/li>\n\n<li>Un control manual para apagar las luces.<\/li><\/ul>\n\n<p>Se permiten controles de encendido totalmente autom\u00e1tico sin control manual en pasillos donde el funcionamiento manual pondr\u00eda en peligro la seguridad o la protecci\u00f3n de los ocupantes.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"c405214-occupant-sensor-control-function-in-corridors\">C405.2.1.4 Funci\u00f3n de control del sensor de ocupaci\u00f3n en pasillos.<\/h4>\n\n<p>Los controles con sensor de ocupaci\u00f3n en pasillos deber\u00e1n reducir uniformemente la potencia de iluminaci\u00f3n hasta un punto de ajuste de ocupado que no sea superior al 50 por ciento de la potencia total en un plazo de 20 minutos despu\u00e9s de que todos los ocupantes hayan abandonado el espacio.<\/p>\n\n<p>Excepci\u00f3n: Pasillos con menos de dos pies-candela de iluminaci\u00f3n en el suelo en el punto m\u00e1s oscuro con todas las luces encendidas.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"ashrae-901-2022\">ASHRAE 90.1 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"9411-a-local-control\">9.4.1.1 a Control local<\/h4>\n\n<p>Deber\u00e1 haber uno o m\u00e1s dispositivos de control manual de la iluminaci\u00f3n que proporcionen control de ENCENDIDO y APAGADO<br>de toda la iluminaci\u00f3n del espacio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-g-automatic-reduction-control\">9.4.1.1 g Control de reducci\u00f3n autom\u00e1tica<\/h4>\n\n<p>La potencia de iluminaci\u00f3n general del espacio se reducir\u00e1 autom\u00e1ticamente al menos en un 50% en un plazo de 15 minutos desde que todos los ocupantes abandonen el espacio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-h-automatic-full-off-control\">9.4.1.1 h Control de apagado total autom\u00e1tico<\/h4>\n\n<p>Toda la iluminaci\u00f3n del espacio se apagar\u00e1 autom\u00e1ticamente en un plazo de 15 minutos desde que todos los ocupantes abandonen el espacio.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"9411-i-scheduled-shutoff\">9.4.1.1 i Apagado programado<\/h4>\n\n<p>Toda la iluminaci\u00f3n del espacio se apagar\u00e1 autom\u00e1ticamente durante los periodos en los que el espacio est\u00e9 programado para estar desocupado.<\/p>\n\n<p>** NOTA: Se deber\u00e1 implementar al menos uno de 9.4.1.1 h o 9.4.1.1 i.<\/p><\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\" id=\"title-24-2022\">T\u00edtulo 24 \u2013 2022<\/h3>\n\n<h4 class=\"wp-block-heading\" id=\"1301-a-manual-area-controls\">130.1 (a) Controles manuales por \u00e1rea.<\/h4>\n\n<p>Cada \u00e1rea delimitada por tabiques hasta el techo deber\u00e1 disponer de controles de iluminaci\u00f3n que permitan encender y apagar manualmente la iluminaci\u00f3n de esa \u00e1rea.<\/p>\n\n<h4 class=\"wp-block-heading\" id=\"1301-c-shutoff-controls\">130.1 (c) Controles de apagado.<\/h4>\n\n<p>En los pasillos, la iluminaci\u00f3n deber\u00e1 controlarse mediante controles de detecci\u00f3n de ocupantes de apagado total o parcial que reduzcan por separado la potencia de iluminaci\u00f3n en cada espacio al menos un 50 por ciento cuando el espacio est\u00e9 desocupado. Los controles de detecci\u00f3n de ocupantes deber\u00e1n ser capaces de encender autom\u00e1ticamente la iluminaci\u00f3n al 100 % solo en el espacio controlado de forma independiente, y deber\u00e1n activarse autom\u00e1ticamente desde todas las v\u00edas de evacuaci\u00f3n previstas.<\/p><\/div><\/div><\/div><\/div><div class=\"wp-block-group rzpg_base_group rzpg_flex_group rzpg_inquiry\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><h3 class=\"wp-block-heading\">Queremos escucharle.<\/h3>\n\n<p>Deje que Rayzeek le ayude a dise\u00f1ar y ofrecerle una soluci\u00f3n de iluminaci\u00f3n de ahorro energ\u00e9tico a medida.<\/p>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f17937-o1\" lang=\"en-US\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/es\/wp-json\/wp\/v2\/pages\/17996#wpcf7-f17937-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Formulario de contacto\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/es\/wp-json\/wp\/v2\/pages\/17996#wpcf7-f17937-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"17937\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.9.4\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f17937-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<div class = \"bs_cf_name\">\n\t<div>\n\t\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Your Name\" type=\"text\" name=\"your-name\" \/><\/span>\n\t\t<\/p>\n\t<\/div>\n<\/div>\n<div class = \"bs_cf_mail\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"Email*\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_phone\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Phone\" type=\"text\" name=\"your-phone\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_company\">\n\t<p><label> <span class=\"wpcf7-form-control-wrap\" data-name=\"your-company\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"Company Name*\" type=\"text\" name=\"your-company\" \/><\/span> <\/label>\n\t<\/p>\n<\/div>\n<div class = \"bs_cf_message\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\">Message (OPTIONAL)<\/textarea><\/span>\n\t<\/p>\n<\/div>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Enviar\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"es\"\/><\/form>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg\" alt=\"\" class=\"wp-image-17861\" srcset=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-1024x1024.jpg 1024w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-300x300.jpg 300w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-150x150.jpg 150w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-768x768.jpg 768w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-12x12.jpg 12w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta-100x100.jpg 100w, https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/energy-code-cta.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Los pasillos, ya sea en edificios comerciales, instituciones educativas o centros sanitarios, son zonas de mucho tr\u00e1nsito que a menudo permanecen iluminadas durante todo el d\u00eda, lo que conlleva un consumo energ\u00e9tico significativo.<\/p>","protected":false},"author":1,"featured_media":17998,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"article_term":"","article_term_alternate":"","article_term_def":"","article_hook":"","auto_links":"","article_topic":"","article_fact_check":"","mt_social_share":"","mt_content_meta":"","mt_glossary_display":"","glossary_heading":"","glossary":"","glossary_alter":"","glossary_def":"","article_task":"","footnotes":""},"class_list":["post-17996","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Corridor Energy Code Design Guide - Rayzeek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rayzeek.com\/es\/guia-de-diseno-de-corredores\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Corridor Energy Code Design Guide - Rayzeek\" \/>\n<meta property=\"og:description\" content=\"Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rayzeek.com\/es\/guia-de-diseno-de-corredores\" \/>\n<meta property=\"og:site_name\" content=\"Rayzeek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/bester001\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T02:22:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@RayzeekTech\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rayzeek.com\/corridor-design-guide\",\"url\":\"https:\/\/www.rayzeek.com\/corridor-design-guide\",\"name\":\"Corridor Energy Code Design Guide - Rayzeek\",\"isPartOf\":{\"@id\":\"https:\/\/www.rayzeek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rayzeek.com\/corridor-design-guide#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/corridor-design-guide#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"datePublished\":\"2024-05-21T08:41:22+00:00\",\"dateModified\":\"2024-06-05T02:22:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rayzeek.com\/corridor-design-guide#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rayzeek.com\/corridor-design-guide\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.rayzeek.com\/corridor-design-guide#primaryimage\",\"url\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"contentUrl\":\"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg\",\"width\":1920,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rayzeek.com\/corridor-design-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rayzeek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Corridor Design Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rayzeek.com\/#website\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"name\":\"Rayzeek\",\"description\":\"Motion Sensor &amp; Occupancy Sensor Expert\",\"publisher\":{\"@id\":\"https:\/\/www.rayzeek.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rayzeek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rayzeek.com\/#organization\",\"name\":\"Rayzeek\",\"url\":\"https:\/\/www.rayzeek.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"contentUrl\":\"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png\",\"width\":260,\"height\":101,\"caption\":\"Rayzeek\"},\"image\":{\"@id\":\"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/bester001\/\",\"https:\/\/x.com\/RayzeekTech\",\"https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Corridor Energy Code Design Guide - Rayzeek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rayzeek.com\/es\/guia-de-diseno-de-corredores","og_locale":"es_ES","og_type":"article","og_title":"Corridor Energy Code Design Guide - Rayzeek","og_description":"Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption.","og_url":"https:\/\/www.rayzeek.com\/es\/guia-de-diseno-de-corredores","og_site_name":"Rayzeek","article_publisher":"https:\/\/www.facebook.com\/bester001\/","article_modified_time":"2024-06-05T02:22:38+00:00","og_image":[{"width":1920,"height":500,"url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@RayzeekTech","twitter_misc":{"Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rayzeek.com\/corridor-design-guide","url":"https:\/\/www.rayzeek.com\/corridor-design-guide","name":"Corridor Energy Code Design Guide - Rayzeek","isPartOf":{"@id":"https:\/\/www.rayzeek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rayzeek.com\/corridor-design-guide#primaryimage"},"image":{"@id":"https:\/\/www.rayzeek.com\/corridor-design-guide#primaryimage"},"thumbnailUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","datePublished":"2024-05-21T08:41:22+00:00","dateModified":"2024-06-05T02:22:38+00:00","breadcrumb":{"@id":"https:\/\/www.rayzeek.com\/corridor-design-guide#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rayzeek.com\/corridor-design-guide"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.rayzeek.com\/corridor-design-guide#primaryimage","url":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","contentUrl":"https:\/\/www.rayzeek.com\/wp-content\/uploads\/2024\/05\/corridor-energy-code-banner.jpg","width":1920,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.rayzeek.com\/corridor-design-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rayzeek.com\/"},{"@type":"ListItem","position":2,"name":"Corridor Design Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.rayzeek.com\/#website","url":"https:\/\/www.rayzeek.com\/","name":"Rayzeek","description":"Motion Sensor &amp; Occupancy Sensor Expert","publisher":{"@id":"https:\/\/www.rayzeek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rayzeek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.rayzeek.com\/#organization","name":"Rayzeek","url":"https:\/\/www.rayzeek.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/","url":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","contentUrl":"https:\/\/rayzeek.com\/wp-content\/uploads\/2021\/05\/rayzeek-logo-retina.png","width":260,"height":101,"caption":"Rayzeek"},"image":{"@id":"https:\/\/www.rayzeek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/bester001\/","https:\/\/x.com\/RayzeekTech","https:\/\/www.youtube.com\/channel\/UCTKY5jxVUKLU8PVz0hdFzVA"]}]}},"_links":{"self":[{"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/pages\/17996","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/comments?post=17996"}],"version-history":[{"count":11,"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/pages\/17996\/revisions"}],"predecessor-version":[{"id":18158,"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/pages\/17996\/revisions\/18158"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/media\/17998"}],"wp:attachment":[{"href":"https:\/\/www.rayzeek.com\/es\/wp-json\/wp\/v2\/media?parent=17996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}